Deutronicstr. 5, D - 84166 Adlkofen, Germany
Tel.: +49 (0) 8707 920-0
Fax: +49 (0) 8707 1004
E-mail: [email protected]
http://www.deutronic.com
DBL Operating Instructions / MPC4
Last updated: 03.12.2020
Page 7 of 26
-
After showing the version information or after language selection the display changes
automatically to the main screen (see chapter 5.3 Main Screen).
-
The desired line can be selected with the Up / Down buttons in the main screen.
Selecting START activates the load detection circuit and with a valid load connected -
depending on the pre-set mode - SUPPLYMODE or charging mode will be started (the
particular operation mode is shown via LED 1-3; see chapter 8 Signalling / LED and
Signal Lamp).
The supply of the load or the charging process will be stopped and the load detection
will be deactivated by pressing the ‘STOP’ button.
-
Additional to the display the operating status of the charger can be displayed via LED
1 to 3 or with a powerful glowing external signal lamp option (on request). Further
information regarding accessories you will find under www.deutronic.com.
-
Beside the optical signalisation it is possible to show the operating status of the
charger with the help of an external control (e.g. PLC). Therefore three potential-free
relays are available on the 25 pole interface. Also through this interface you can use a
remote OFF function as further option.
Further details regarding all available interface functions and the optional software
tools from Deutronic for updates, configuration and diagnostic tasks you will get on
request via Deutronic.