![EDWANZ group Deutronic DBL-MPC4 Series Manual Download Page 13](http://html.mh-extra.com/html/edwanz-group/deutronic-dbl-mpc4-series/deutronic-dbl-mpc4-series_manual_2365867013.webp)
Deutronicstr. 5, D - 84166 Adlkofen, Germany
Tel.: +49 (0) 8707 920-0
Fax: +49 (0) 8707 1004
E-mail: [email protected]
http://www.deutronic.com
DBL Operating Instructions / MPC4
Last updated: 03.12.2020
Page 13 of 26
5.5.4. Charge Menu (parameters for the CHARGEMODE)
Picture 6 – charge menu
Parameter
Description
Figures / range of adjustment
U in [V]
Charging voltage
[2 ... 17] V (or max. 20 V on type DBL800-14)
U
tri
in [V]
Trickle voltage
[U
min
... U
charging voltage
] V
U
min
in
[V]
Starting voltage
[5 … U
tri
] V
Required minimum voltage of the battery - this
defines the voltage limit which must be
exceeded by the battery before starting to
charge [1].
I
max
in [A]
Current limit
[(I
tri
+ I
re
) ... I
max
] A
The lower limit is dynamic and depends on the
configured values I
tri
and I
re
.
The possible maximum to reach depends on the
power class of the device (see data sheet). [2]
ATTENTION: The current limit has to be
checked and if necessary adapted to the
connected equipment (e.g. charging cable and
clamps)
I
tri
in [A]
Trickle charging
current
[1 ... 20] A; Limiting value from which the DBL
switches to trickle charge.
I
re
in [A]
Recharge current
[0.5 … 30] A; Threshold (Delta-Value) above I
tri
,
from which on the DBL switches back to
CHARGEMODE.