Deutronic Elektronik GmbH
Deutronicstr. 5, D - 84166 Adlkofen
Tel.: +49 8707 920-0
Fax: +49 8707 1004
E-Mail: [email protected]
http://www.deutronic.com
D-IBM2900
Stand: 08.03.2022
Seite 21 von 25
Overview
Error pattern
Possible Cause
Remedy
No output voltage
during battery
operation (LED HV ON
off)
Press the emergency off button
Unlock the (emergency) off
button
Input plug connector connected
Check whether the input
connector is plugged in and
locked. There is a jumper of
Pin5/Pin6 in the connector, if
this is interrupted, the HV
output is switched off -> Plug
in and lock input connector,
check jumper Pin5/Pin6 if
necessary.
Error battery module(s)
Check battery module, if
necessary replace
DBL charger at D-
IBM2900 without
function although LED
HV-ON at D-IBM2900 is
on
Input plug at the DBL charging device
is not locked
Check the connection and lock
the plug
DBL charging device
Change DBL charging device
Malfunction error output Defective error output
Replace D-IBM2900
SOC display is not
working AND HV-ON
shines.
Micro controller for the SOC display
defective
Replace D-IBM2900
D-IBM2900 is not
charged
Missing supply
Upstream fuse, check voltage
(Emergency) Off switch pressed
Unlock (emergency) off switch