1.4   What are the service intervals?

Every 24 months

we advise you to do maintenance service 

(water resistance, movement accuracy 

test).

Every 5 years

we advise you to do a complete mainte-

nance service (complete movement revi-

sion, water resistance, accuracy and 

functionality complete revision).

Who should I contact for a 

maintenance service or battery 

replacement?

We recommend that you contact an au-

thorized Edox retailer, as they are the only 

certified specialists equipped with the 

tools and apparatus required carrying out 

the work and the necessary checks in a 

professional  manner.  Furthermore,  only 

these certified specialists can guarantee 

that their work is carried out in accord-

ance with Edox’ strict quality standards. 

Make sure that right after each battery 

change the watch has been water-re-

sistant tested.

1.5  Environmental protection

Collection and treatment of end of life 

Quartz watches*

This product should not be disposed of 

with household waste. It has to be re-

turned to a local authorized collection 

system.  By  following  this  procedure  you 

will contribute to the protection of the en-

vironment and human health. The recy-

cling of the materials will help to conserve 

natural resources.

*valid  in  EU  member  states  and  in  any 

countries with corresponding legislation.

2.  PRECISION TOLERANCES

Mechanical watches

The mechanical Edox watch with an auto-

matic movement does not need to be 

wound by hand. 

The motion of your wrist makes the rotor 

(oscillating weight or mass) turn, thereby 

winding up the mainspring of the watch 

movement. 

The everyday activity of life is sufficient in 

itself to wind up an automatic Edox watch 

and it will run continually, even if it is re-

moved at night. However, if not worn for 

approximately 40 hours, it will stop. To 

make the watch work again, turn the 

crown clockwise about 20 times. Now set 

the time and if possible the date, etc.

2.1  Mechanical watches accuracy

Depending on the movement, the daily 

tolerance of a mechanical watch can be of 

30 seconds. If you notice a bigger toler-

ance rate, you can have your watch ad-

justed at a service center in your country, 

free of charge within the guarantee peri-

od.

2.2   Chronometer watches accuracy

Every Edox Chronometer comes with a 

rating certificate issued after an official 

test  by  the  Swiss  Official  Chronometer 

Testing Institute (COSC). The accuracy of 

the watch movement is tested electroni-

cally at the COSC during 15 days in differ-

ent positions and at different 

temperatures. The average daily rating 

must not exceed -4/+6 seconds per day.

Only Edox watches which have success-

fully  undergone  the  official  COSC  rating 

procedure qualify as chronometers.

3.   GENERAL INFORMATIONS

3.1  Helium escape valve

Decompression system which allows he-

lium to escape from inside the watch 

when the watch is worn for professional 

use  in  pressure  chambers.  (Long-term 

underwater work, crude oil exploration, 

etc.)

Important: The Edox helium valve opens 

and closes automatically (for the models 

wearing  the  new  automatic  Helium  es-

cape valve). The models wearing a non-

automatic Helium escape valve must have 

the valve screw down in order to guaran-

tee the water resistance of the watch. 

Unscrew the Helium escape valve only to 

release the gas from the watch. Do not 

unscrew it under water in order to prevent 

water entering the mechanism.

3.2  Tachymeter scale 

Some Edox Chronograph watches have a 

tachymeter scale. With this scale it is pos-

sible to measure the speed. The distance 

is  1  km.  To  measure  the  elapsed  time 

press the start/stop button when the vehi-

cle (power-boat) passes the starting and 

the final point or target. The figure shown 

by the hand on the tachymeter scale indi-

cates the average speed in kilometers. If 

for instance a car covers a 1 km distance 

in 30 seconds, you can consider it to an 

average speed of 120 km per hour.

Summary of Contents for Watch

Page 1: ...Instruction Manual ...

Page 2: ...OMATIC WATCHES 5 4 3 HAND WINDING WATCHES 6 4 4 QUARTZ CHRONOGRAPH 7 4 5 QUARTZ WATCHES 8 4 6 CHRONORALLY MOVEMENT 10 4 7 INSTRUCTION ON HOW TO SHORTEN A RUBBER STRAP 12 Edox 011 4 Edox 012 4 Edox 013 7 Edox 015 7 Edox 019 7 Edox 10 7 Edox 21 8 Edox 23 9 Edox 26 9 Edox 27 9 Edox 28 8 Edox 30 4 Edox 33 9 Edox 34 9 Edox 36 10 Edox 37 5 Edox 38 8 Edox 45 4 Edox 47 5 Edox 48 9 Edox 56 9 Edox 57 9 Edox...

Page 3: ...x watches bought from non authorized retailers since Edox is not able to check if the watches were handled and stocked correctly Any further claim against Montres Edox Vista SA for example for damages addi tional to the above described warranty is expressly excluded except mandatory statutory rights the purchaser may have against the manufacturer The above manufacturer s warranty Is independent of...

Page 4: ...ockwise about 20 times Now set the time and if possible the date etc 2 1 Mechanical watches accuracy Depending on the movement the daily tolerance of a mechanical watch can be of 30 seconds If you notice a bigger toler ance rate you can have your watch ad justed at a service center in your country free of charge within the guarantee peri od 2 2 Chronometer watches accuracy Every Edox Chronometer c...

Page 5: ...ect Lighter than the steel it possesses the main characteristics cor rosion resistance dilation etc Its proper ties make titanium a material determinedly adapted to the modern tech nologies and intended for fields of appli cation such as the aeronautics the automobile the surgery the electronics 3 8 Stainless steel 316L The stainless steel used for Edox cases and bracelets appears among the best a...

Page 6: ...ositioned against the case the crown ensures that the watch is water resistant Occasional winding if the watch has not been worn for more than 42 hours or more wind it up with the crown in posi tion 1 2 Time setting hours minutes and sec onds Pull the crown out to position 3 The seconds hand will stop Turn the crown forwards or backwards Synchronise the seconds by pushing the crown back to positio...

Page 7: ...hes should be wound daily preferably in the morning To do this turn the crown forward until you feel resist ance After this operation the watch will work approximately 35 hours after being fully wound up Edox 92 Venus movement The hand setting is effected in the same manner as for any other watch That is to say by pulling the winding crown and then turning same to the right or to the left The date...

Page 8: ...ting of the 12 hours hand to zero crown in position 2 and pusher A After setting the hands to their original positions return to crown position 1 Edox 015 Watch functions The crown has 3 positions 1 Normal position wearing posi tion when the crown is positioned against the case the crown ensures that the watch is water resistant 2 Correcting the date pull the crown out to position 2 turn the crown...

Page 9: ...on A Stop Press Button A Reset to zero Press Button B Time keeping Timing lap times Start Press Button A Display the lap time Press Button B Catching up on the time lapsed Start Press Button B Stop Press Button A Reset to zero Press Button B Adjusting the chronograph hands to the zero position When one or more of the chronograph hands are not in the correct zero position and must be adjusted Pull ...

Page 10: ...ormal position wearing posi tion when the crown is positioned against the case the crown ensures that the watch is water resistant 2 Correcting the date pull the crown out to position 2 turn the crown forwards and push it back to position 1 3 Time setting hours minutes and sec onds Pull the crown out to position 3 The seconds hand will stop Turn the crown forwards or backwards Synchronise the seco...

Page 11: ...4 at 9h Hand 5 at 6h AT Penalty Penalties Additional Time Hand 4 at 9h Has the following functions modes Time display of time Race timing recording for one or more races Replay display of timings for recorded races Total Time or T Time display of cumulative total of recorded times Countdown or CTDown countdown display Chrono chronograph display Useful tips With this calibre developed exclusively f...

Page 12: ... the recording to be cancelled Press push piece B for 5 seconds Hands 1 and 2 will position to zero and this re cording will then be cancelled definitively Display of recorded race times Replay mode Press push piece C to position Hand 4 in Replay mode Press push piece A according to the number of recorded races in order to review the recorded times Display of total recorded time Total Time mode Pr...

Page 13: ...total accumulated time in Total Time mode and the Race and Replay modes are reset to zero Adjusting the hands Push piece A enables you to adjust the various hands Push piece B enables you to change the hand to be adjusted Press push piece C to position Hand 4 in Time mode Pull push piece C Press push pieces A and B simultaneously for 5 seconds Hands 1 and 2 will position themselves at 12h Press pu...