background image

General Notes

 

 
 
Dear customer, 
 
Thank you for choosing a 

Bühler 

high-quality product for supporting you in your work. 

 
The 

Bühler 

shakers were developed for the use in laboratories. 

 
If you pay attention to the following points, the device will reward you with long life and 
optimal operation. 
 
 
 

1) Read the operating instructions carefully before initial operation. 
 
2) The user must acquaint himself with the safety instructions and operating 

conditions in order to avoid damage / injuries to material and personnel. 

  
3) Liability and all claims under warranty end immediately in case of damages 

which result from misuse and / or abuse. 

 
4) The devices were carefully checked for perfect functioning and condition before 

delivery. 

 
5) Necessary servicing or repair work may only be done by personnel of the 

Edmund Bühler GmbH 

technical service department, their authorized agents or 

personnel trained by 

Edmund Bühler GmbH

 
6) For shipping, the device must be adequately and safely packed. If possible, use 

the original packing. 

 
7) If the device is returned to 

Edmund Bühler

 for repair, it should be cleaned and 

free of any harmful substances or residues.  

 
These operating instructions are protected by copyright. 

Edmund Bühler GmbH   ALLGEM\BED.SMG/BEDSME/TXTE.DOC – 01/08 

3

Summary of Contents for KS 15 control

Page 1: ...Operating Instructions B hler Shakers Edmund B hler GmbH ALLGEM BED SMG BEDSME TXTE DOC 01 08 1...

Page 2: ...2 SM 30 C and TL 10 16 4 3 1Change of the Angle of Inclination Orbital Shaker TL 10 17 4 4 Adjustment of the Counterweight TiMix 5 TiMix 5 control 17 4 5 Exchange of the Rack Systems of KS 15 TiMix 2...

Page 3: ...all claims under warranty end immediately in case of damages which result from misuse and or abuse 4 The devices were carefully checked for perfect functioning and condition before delivery 5 Necessar...

Page 4: ...hes Coloring and decoloring of gels Thanks to their different motions and high loading capacities and especially their variable Combifix rack systems the B hler shakers of the Edmund B hler GmbH offer...

Page 5: ...r models VKS 75 are designed for operation at the ground Compare operating voltage on the rating plate at the back of the device with your supply voltage If they match connect the device ATTENTION The...

Page 6: ...200 250 300 350 400 420 The Operation Panel has two control knobs With the left one the required speed can be adjusted speed range see Technical Data The right control knob is for the timer function...

Page 7: ...the function forward direction 6 Mode key for choosing the function backward direction 7 Display Actual speed running time large display 8 Display Set speed running time small display at the upper rig...

Page 8: ...symbol is blinking Operating Mode A When the device is switched on the speed is 0 both set value and actual value The timer function is not active If a time was programmed the speed is 0 when the tim...

Page 9: ...ol knob to the right the display shows SV Set Value When turning the control knob slowly the value can be changed by seconds when turning it fast in minute steps When values above 60 minutes are enter...

Page 10: ...turning the control knob to the right If the value for the time is 0 the device starts Press keys or for entering the running time Adjust the required time with the control knob the display shows SV...

Page 11: ...e Mode keys With the Mode keys you can change between the functions Add Del or Rem Run Stop Prog and Rpt The meaning of these functions is described below 248 3 P4 Add 248 3 Rem 248 3 RUN 120 P0 STOP...

Page 12: ...d In segments 7 and 8 the next program to be integrated in the program flow is displayed The pogram can be selected with the control knob and integrated in the program flow by pressing the OK key Maxi...

Page 13: ...switched on if Rpt yes You can choose between yes and no with the control knob 4 How to edit programs Within each program you can program one speed and one running time During programming the number o...

Page 14: ...amp can be defined Press key or until PROG appears on the display The number of the program is shown at the upper right side PO Confirm program No P0 with the OK key The speed appears on the display E...

Page 15: ...program which shall run first e g P5 Confirm with OK then select the next program and confirm again with OK In this way max 5 programs can be lined up 532 Now you can choose whether this program flow...

Page 16: ...motion can be changed by means of the coupling lever at the right side The coupling lever must audibly snap into its final position Pull out coupling lever orbital motion Push in coupling lever to and...

Page 17: ...actly in the direction of the finder sleeve 2 see fig 1 Switch the shaker off turn the shaking plate 9 by hand into the furthest position at the right then the adjustment spindle 3 and the counterweig...

Page 18: ...Edmund B hler GmbH ALLGEM BED SMG BEDSME TXTE DOC 01 08 18...

Page 19: ...and remove the rack system Fasten the shaking plate to the respective drillings with the same screws and put the rubber mat on the shaking plate Microplate Shaker TiMix 5 The TiMix 5 shakers can be c...

Page 20: ...ite plastic part POM At the bottom side of the 2 storey top frame there are metal rails On these rails there are outer drillings for fastening the frame and in the middle two drillings close to each o...

Page 21: ...d after removal of the fuse insert ATTENTION Before removal of the fuse insert disconnect the mains plug 5 2 Motor Protection The capacitor drive is equipped with a thermal overload protection In case...

Page 22: ...apply for all shakers type SM 30 EN 61 326 1 2006 05 EN 61 000 3 2 2006 04 EN 61 000 3 3 1995 01 A1 2001 06 A2 2005 11 EN 61 326 1 2006 05 Hechingen January 2008 EDMUND B HLER GMBH 7 0 Warranty The E...