The display shows which program  is running and, alternating, the 

 

 

 

 

speed or the remaining time of this program.  

 

 

 

 

 

 

 

 

 

The shaker can be stopped at any time by pressing the OK key.  

 

 

 

 

Press the OK key again to restart the shaker.  

 

 

 

 

 

 
 

 

 

 

The stored values and the program flow remain stored also after  
the shaker is switched off. If the shaker is operated in a different 
mode, the values of mode C remain stored.  

 

 

 

 

 

 

 

 

 

Switch the device on and press the OK key to restart the shaker. 

 
 
 

 

 

 

To change or delete the program flow, press the key  

 or 

 until 

    „Rem“ 

appears 

on 

the 

display. 

 

 

 

 

With the OK key the programs are deleted from left to right. 

 
 
 

 =

 

 =

 

flashes

 

flashes

 

Rem

 

STOP

32-- 

  P5 

532

 

150

 

 

 

 

 

 

 

 

4.3   Changing the motion 

 

 

Multi-Purpose Shaker KL 2 

 

 

The motion can be changed by means of the coupling lever at the right side: 

The coupling lever must audibly snap into its final position. 

 

- Pull out coupling lever 

 

-> 

orbital motion 

- Push in coupling lever 

 

-> 

to-and-fro motion 

 

 

ATTENTION: 

 

Change the motion only when the device is running 

   with 

minimum 

speed! 

 

 

 

Changing the shaking motion at high speed can cause 

   damages 

to 

the 

device. 

 
 

 

Universal shaker SM 30 

 

The motion can be changed by actuating the lever at the front of the shaking plate: 

 

  Move the shaking plate forward by hand until the right front edge of the 

  shaking plate corresponds with the mark on the housing.   

  Loosen the star-shaped knob at the front of the shaking plate. 

  Move knob to the far left position => to-and-fro motion 

  Move knob to the far right position => orbital motion  

  After having chosen the motion, tighten the star-shaped knob again. 

 

Edmund Bühler GmbH   ALLGEM\BED.SMG/BEDSME/TXTE.DOC – 01/08 

16

Summary of Contents for KS 15 control

Page 1: ...Operating Instructions B hler Shakers Edmund B hler GmbH ALLGEM BED SMG BEDSME TXTE DOC 01 08 1...

Page 2: ...2 SM 30 C and TL 10 16 4 3 1Change of the Angle of Inclination Orbital Shaker TL 10 17 4 4 Adjustment of the Counterweight TiMix 5 TiMix 5 control 17 4 5 Exchange of the Rack Systems of KS 15 TiMix 2...

Page 3: ...all claims under warranty end immediately in case of damages which result from misuse and or abuse 4 The devices were carefully checked for perfect functioning and condition before delivery 5 Necessar...

Page 4: ...hes Coloring and decoloring of gels Thanks to their different motions and high loading capacities and especially their variable Combifix rack systems the B hler shakers of the Edmund B hler GmbH offer...

Page 5: ...r models VKS 75 are designed for operation at the ground Compare operating voltage on the rating plate at the back of the device with your supply voltage If they match connect the device ATTENTION The...

Page 6: ...200 250 300 350 400 420 The Operation Panel has two control knobs With the left one the required speed can be adjusted speed range see Technical Data The right control knob is for the timer function...

Page 7: ...the function forward direction 6 Mode key for choosing the function backward direction 7 Display Actual speed running time large display 8 Display Set speed running time small display at the upper rig...

Page 8: ...symbol is blinking Operating Mode A When the device is switched on the speed is 0 both set value and actual value The timer function is not active If a time was programmed the speed is 0 when the tim...

Page 9: ...ol knob to the right the display shows SV Set Value When turning the control knob slowly the value can be changed by seconds when turning it fast in minute steps When values above 60 minutes are enter...

Page 10: ...turning the control knob to the right If the value for the time is 0 the device starts Press keys or for entering the running time Adjust the required time with the control knob the display shows SV...

Page 11: ...e Mode keys With the Mode keys you can change between the functions Add Del or Rem Run Stop Prog and Rpt The meaning of these functions is described below 248 3 P4 Add 248 3 Rem 248 3 RUN 120 P0 STOP...

Page 12: ...d In segments 7 and 8 the next program to be integrated in the program flow is displayed The pogram can be selected with the control knob and integrated in the program flow by pressing the OK key Maxi...

Page 13: ...switched on if Rpt yes You can choose between yes and no with the control knob 4 How to edit programs Within each program you can program one speed and one running time During programming the number o...

Page 14: ...amp can be defined Press key or until PROG appears on the display The number of the program is shown at the upper right side PO Confirm program No P0 with the OK key The speed appears on the display E...

Page 15: ...program which shall run first e g P5 Confirm with OK then select the next program and confirm again with OK In this way max 5 programs can be lined up 532 Now you can choose whether this program flow...

Page 16: ...motion can be changed by means of the coupling lever at the right side The coupling lever must audibly snap into its final position Pull out coupling lever orbital motion Push in coupling lever to and...

Page 17: ...actly in the direction of the finder sleeve 2 see fig 1 Switch the shaker off turn the shaking plate 9 by hand into the furthest position at the right then the adjustment spindle 3 and the counterweig...

Page 18: ...Edmund B hler GmbH ALLGEM BED SMG BEDSME TXTE DOC 01 08 18...

Page 19: ...and remove the rack system Fasten the shaking plate to the respective drillings with the same screws and put the rubber mat on the shaking plate Microplate Shaker TiMix 5 The TiMix 5 shakers can be c...

Page 20: ...ite plastic part POM At the bottom side of the 2 storey top frame there are metal rails On these rails there are outer drillings for fastening the frame and in the middle two drillings close to each o...

Page 21: ...d after removal of the fuse insert ATTENTION Before removal of the fuse insert disconnect the mains plug 5 2 Motor Protection The capacitor drive is equipped with a thermal overload protection In case...

Page 22: ...apply for all shakers type SM 30 EN 61 326 1 2006 05 EN 61 000 3 2 2006 04 EN 61 000 3 3 1995 01 A1 2001 06 A2 2005 11 EN 61 326 1 2006 05 Hechingen January 2008 EDMUND B HLER GMBH 7 0 Warranty The E...

Reviews: