Solution-8 Installation Manual
Page 27
Electronics Design & Manufacturing
ISSUE401.DOC
Zone Configurations
Locations 164 - 195
0
...
0
Each zone has four programming locations allocated to it. The first of these locations contains the character for
the zone option (1 to 12), the second of these locations contains the character for the zone type (0 to 3). The third
location contains the channel number for the alarm reporting and the fourth location contains the expansion code.
Example:
To program Zone 1 as a delay-1, lockout siren, lockout dialler : Enter '4' into location 164 and a '1' into location
165. To make Zone 1 report on channel one to a high speed receiver, program a '1' into location 166 and a '9' into
167.
Channel
The code entered in this location will determine on which channel alarms will be reported. For 3+1 or 4+1
formats this location has no effect.
Expansion
If you do not require alarm reports from a zone, program its expansion code to '0'. The dialler will not be
triggered by alarms on a zone that has an expansion code of '0.' The zone will function normally otherwise.
In the 3+1 and 4+1 formats this location selects the actual code to be sent.
If you want the zone to report an alarm then you must specify a digit other than '0' (zero) for the expansion code.
When using HI-SPEED expanded format, program a '9' as the expansion code, this will ensure correct
transmissions.
If you are using 4+2 format, the expansion code will be sent first as the 10s digit and the channel number will
follow as the units digit.
Zone
Location
Default
Number
Number
Option
Type
Channel
Expansion
Zone 1
164 to 167
1
1
1
9
Zone 2
168 to 171
1
0
2
9
Zone 3
172 to 175
1
0
3
9
Zone 4
176 to 179
1
0
4
9
Zone 5
180 to 183
1
0
5
9
Zone 6
184 to 187
1
0
6
9
Zone 7
188 to 191
1
0
7
9
Zone 8
192 to 195
1
3
8
9
Note:
The Zone configuration table is presented on the previous page.