background image

17

ENGLISH

INSTALLER

Assembling the right-hand side panel (3 and 4)

Screw on the top right-hand side panel, the external right-hand profile and the right-hand front profile. Slot the top
right-hand side panel. Screw on the central spacers until obtaining the complete right-hand side panel.

STEEL CLADDING

Summary of Contents for Blade2 12 Up

Page 1: ...For all updates visit www edilkamin com UK Installation use and maintenance page 2 PELLET STOVE Blade2 12 Up ...

Page 2: ...with EU Regulation 305 2011 and harmonised EU standard EN 14785 2006 PELLET STOVE tradename EDILKAMIN model BLADE2 12 UP SERIAL NUMBER Nameplate reference Performance declaration DoP EK n 216 Nameplate reference And also declares that the BLADE Up wood pellet stove satisfies the requirements of the following European directives 2014 35 UE Low Voltage Directive 2014 30 UE Electromagnetic Compatibil...

Page 3: ...ribed The product s CE marking plate is located on the back kW Kg h bar Max fuel consumption Max Verbrauch von Brennmaterial Consommation max de combustible Consumo massimo kW kW kW Heat input Thermische Leistung eingefuhrt Puissance calorifique introduite Potenza termica introdotta Nominal heat output Gesamt Nennleistung Puissance normal total Potenza nominale totale Boiler output Leistung Wasser...

Page 4: ...e may catch fire and environmental damage may ensue cleaning the hearth when hot DO NOT CLEAN THE HEARTH WITH A VACUUM CLEANER WHILE IT IS HOT Risk of damage to the cleaner and smoke in the room cleaningthefumesductwithcleaningproducts DO NOT CLEAN THE PRODUCT WITH FLAMMABLE PRODUCTS Risk of fire and blowback cleaning the hot glass pane with unsuitable cleaning products DO NOT CLEAN THE GLASS WHIL...

Page 5: ... 34 5 34 5 17 5 17 5 19 17 5 34 5 Ø 8 cm uscita fumi 28 28 6 5 6 5 29 29 61 61 90 113 19 34 5 17 5 19 17 5 34 5 34 5 USER INSTALLER NOTE The names of Edilkamin offi cial authorised technical assistance centres and distributors are available ONLY at www edilkamin com Ducting length and vent outlet temperature depend on the conditions of use and installation It is therefore suggested to size the duc...

Page 6: ... 34 5 17 5 17 5 19 17 5 34 5 Ø 8 cm uscita fumi 28 28 6 5 6 5 29 29 61 61 90 113 39 19 34 5 17 5 19 17 5 34 5 34 5 USER INSTALLER NOTE The names of Edilkamin offi cial authorised technical assistance centres TAC and distributors are available ONLY at www edilkamin com Ducting length and vent outlet temperature depend on the conditions of use and installation It is therefore suggested to size the d...

Page 7: ...ale above 80 mm Air intake diameter 40 mm Hot air duct diameter 60 mm Weight including packaging steel soapstone 175 217 kg Energy efficiency class according to UE 2015 1186 regulation Class A G A TECHNICAL DATA USER INSTALLER A calorific value of 4 8 kW Kg has been used to calculate consumption The heatable volume is calculated based on the assumption of a heating demand of 33 Kcal m hour Accesso...

Page 8: ... 01 Pa Fumes flow rate 8 6 4 2 g s ELECTRICAL SPECIFICATIONS Power supply 230 Vac 10 50 Hz Nominal power absorbed 160 W Reduced power absorbed 35 W Power absorbed in stand by 3 W Power absorption during ignition 300 W Remote control frequency provided 2 4 GHz Protection Fusibile 4 AT 250 Vac 5x20 EDILKAMIN s p a reserves the right to modify the product without notification in the interests of impr...

Page 9: ...emica minima elmin 0 035 kW In standby elsb 0 003 kW F 2 7 0 dal 2022 NO NO con opzione di controllo a distanza SI F 3 1 0 dal 2022 Contatti Nome e indirizzo del fabbricante www edilkamin com EDILKAMIN S p A mail edilkamin com Via Mascagni 7 Direttore Generale 20045 Lainate MI ITALY Paolo Gusella Controllo della temperatura ambiente con rilevamento di finestre aperte Caratteristiche quando l appar...

Page 10: ...n a regulatory fashion recycling them in a regulatory fashion Edilkamin offers Blade in three versions SOAPSTONE BLADE Up STEEL BLADE Up Inside the product you will find the remote control warranty certificate this manual desiccating salts power cable two wall mounting brackets and two cable glands for mounting optional sensors to the back of the product The lever for opening the door is also on t...

Page 11: ...MES DISCHARGE Ø 8 cm cm AND AIR DUCT Ø 6 cm cm STEEL BLADE AND OILSTONE POSSIBLE FUMES DISCHARGE POSITIONS STEEL BLADE AND OILSTONE POSSIBLE AIR DUCT POSITIONS Unducted air exits the stove from the top Unducted air exits the stove from the top standard upper standard upper discharge female discharge female with the optional fumes discharge with the optional fumes discharge kit male kit male ...

Page 12: ...L MOUNTING Mount the stove to the wall with the provided plates a and the brackets b already installed onto the product or use an alternative mounting which ensures that the product is stable and secure Fix the plates to the wall with rawl plugs ...

Page 13: ...THE HOT AIR DUCT To change the direction of the ducting from rear to side summary of operations shown in figures 1 remove the rear cover plate 1 two bolts 2 remove and refit the white bend 2 dia 6 cm towards the side it locates into place 3 reposition the plate in the correct orientation ...

Page 14: ...n 1 Small hardware Countersunk hex screw M5x16 a n 15 Self tapping screw 4 2x9 5 c n 9 The above mentioned elements once they have been mounted will be positioned exploded as shown in the figure The above mentioned elements once they have been mounted will be positioned exploded as shown in the figure below The mounting operations are described in the figures appearing on the following pages below...

Page 15: ... MAKE SURE IT DOES NOT TIP OVER STEEL CLADDING Screw lower left side left outline left front outline inserting then the upper left side screws are used to fix the top Screw lower left side left outline left front outline inserting then the upper left side screws are used to fix the top side panel for a complete left side assembly side panel for a complete left side assembly Use screws a and inner ...

Page 16: ...ft side panel Remove the just laid down top before mounting to ease job if necessary Drawings are just a guideline useful for installing but not always related to the specific model Tight then 3 screws on the left side and 4 screws on the front of the structure ...

Page 17: ...de panel 3 and 4 Screw on the top right hand side panel the external right hand profile and the right hand front profile Slot the top right hand side panel Screw on the central spacers until obtaining the complete right hand side panel STEEL CLADDING ...

Page 18: ...ALLER STEEL CLADDING Insert the assembled right hand side panel Insert the assembled right hand side panel Fasten it to the top and Fasten it to the top and right hand sides with a right hand sides with a screw screw ...

Page 19: ...ctor 11 1 upwards air deflector 11 1 rose for the side fumes discharge 1 rose for the side fumes discharge 1 bag of fasteners 1 bag of fasteners 4 washers in case to adjust the top 4 washers in case to adjust the top BEFORE INSTALLING THE STONES SECURE IT TO THE WALL WITH THE PROVIDED BRACKETS TO MAKE SURE IT DOES NOT TIP OVER Levelling feet The product has 5 feet which can be adjusted with a scre...

Page 20: ...GLISH INSTALLER SOAPSTONE CLADDING Remove product outline replacing it with the new one as illustrated below Remove product outline replacing it with the new one as illustrated below COATING FITTING SEQUENCE ...

Page 21: ...Position the four metal side elements 7 8 9 10 from the bottom Each element snaps into place and then bolts on Each element snaps into place and then bolts on Locate the six stone components see figure below They are not adjustable Locate the six stone components see figure below They are not adjustable ...

Page 22: ...e product and its accessories Level the appliance The appliance may not be installed in a bedroom bathroom or in the same room as other equipment which draws air for combustion from the room itself or in any area with an explosive atmosphere Any extraction fans operating in the same room or area as the product may affect its draw In Italy check the compatibility pursuant to UNI 10683 and UNI 7129 ...

Page 23: ...pen to the sky be made of material rated fire reaction class A1 per UNI EN 13501 or analogous national regulations be certified with a chimney plate if metal be of uniform cross section or vary in cross section only immediately after the outlet not at some mid point of its length THE FUMES DUCT THE FUMES DUCT Further to the general prescriptions for the fumes duct and flue the fumes duct may not b...

Page 24: ... be spaced at least 2 m apart the chimney pot receiving the fumes from the solid fuel appliance or that from the higher storey must be at least 50 cm higher than the other it must extend beyond the back flow zone in Italy refer to UNI 10683 point 6 5 8 it must allow for maintenance of the chimney EXTERNAL AIR INTAKE In general we suggest two ways for ensuring a proper flow of combustion air Indire...

Page 25: ...st not come into contact with the flue pipes or other hot parts of the stove Power up the stove by shifting its switch from 0 to 1 There is a 4 A fuse on the socket with switch located at the rear of the stove switch fuse compartment power supply In certain countries specific regulations apply it is the installer s duty to ensure that the local regulations have been observed The technician who siz...

Page 26: ...tic painted wood coal bark or other such materials in the stove Do not use the stove as an incinerator Caution Using fuels other than those specified can damage the appliance 1 When doing so DO NOT rest the bag of pallets on the top grille since the plastic bag may melt and damage the appliance s paint 2 Use the gloves when loading the stove while it is operating and hence hot to the touch FIRST I...

Page 27: ...ovided if for reasons of use or installation the set ventilation does not allow the necessary heat dissipation the maximum ventilation is automatically started The product also has the following supplementary functions Function Modes in which it can be acti vated What it does Stand By automatic crono when the desired temperature is reached the prod uct switches off and then back on again when the ...

Page 28: ...oduct The Mind APP T M Ä useful for all functions at home with direct connection or outside the home with internet connection and registration If necessary a few functions can also be managed from a SAVE PANEL placed on the product T M Ä By purchasing the Edilkamin optional elements VOICE CONTROL SYSTEMS Alexa or Google Home USER INSTRUCTIONS USER ...

Page 29: ...and after a further 10 the display switches off If any button is pressed with the display on the counter resets If any button is pressed while the display is off the display and the backlighting will switch on and the counter will reset This only refers to the remote control not the product itself In normal use the remote control s batteries should last a year This duration is for illustrative pur...

Page 30: ...roblem on the board In any case contact the TAC The relative function is active Relax airKare EasyTimer Crono EasyTimer and Crono cannot be activated simultaneously Reserve indicator It switches on if the function is active The arrows switch on in sequence to signal that the tank must be filled Presence of flame and stove power USER INSTRUCTIONS FOR USE REMOTE CONTROL POWER ON POWER LEVEL 1 POWER ...

Page 31: ...ET POINTS Setting of the various SET POINTS temperature power fan speed Automatic or Manual mode the product s air power depends on the room temperature or is set by the user Indicates that the product has switched off after the target has been reached with stand by mode active DOES NOT indicate that the function is enabled FAN OFF SPEED 1 SPEED 2 SPEED 3 SPEED 4 SPEED 5 AUTOMATIC Setting Indicate...

Page 32: ...y wait without taking any action During switch off the display shows the message SHUTDOWN If time programming is active the status and programming are displayed alternately 3 seconds on the status bar During the switch on the display will show the status CLEANING SWITCH ON etc The ON OFF button is used to manually start the on or off phase SHUTDOWN ...

Page 33: ...mple press any button and the display will activate then press the button flame symbol The setting can be confirmed with the button or by waiting 5 without pressing any button After confirming SET will stop flashing AUTOMATIC and MANUAL setting Press the AUTO MAN button to switch from manual to automatic mode or conversely Example press a button and activate the display then press the button NOTE ...

Page 34: ...r of the fan being edited appears F1 The fan speed can be increased or decreased with or in the following sequence 1 2 3 4 5 AUTO for the front fan 1 OFF 1 2 3 4 5 AUTO for ducted fans 2 and 3 with button with button You can confirm the setting with the button and then move to the next fan if present only for PLUS ducted versions otherwise you can exit the fan setting page and SET will stop flashi...

Page 35: ... without pressing any button to exit the fan setting and SET will stop flashing even if there are other fans Pressing the button to confirm will take you to the next fan Fan 3 if present Waiting 5 without pressing any button takes you back to the home page with the modified SET Pressing the button to confirm will take you to the next fan Fan 2 if present Pressing the or button modifies the fan spe...

Page 36: ...relative room set point and display the room temperature After setting the installation room temperature or with the room power in manual mode wait 5 without pressing any button and SET will flash then you will exit the settings page Otherwise if you confirm with the button you can set the room set point for zone 2 if the probe is present and active indicated on the bottom bar Press OK to move to ...

Page 37: ...t reduces its power output and after a few minutes switches the fan off too NOTE While the Relax function is active it is not possible to increase the power to level P5 USER AIRKARE FUNCTION This function is available as a standard feature on certain models and as an optional feature on other models check which model you have The function if available can be activated with the product either on or...

Page 38: ... time can be set with hour intervals By activating the Easy Timer function with the product off the user sets the switch on time Pressing the OK button or after 5 without pressing any button the countdown will start with 5 minute intervals The Easy Timer function can be deactivated by press ing the dedicated button The display will show an arrow above the button and the countdown To vary the timer...

Page 39: ...room temperature otherwise at the power setting Pressing the button allows for switching from Crono in Temperature and Crono to Power and vice versa Briefly pressing the button activates or deactivates the timer programmed in advance from the app or remote control NOTE The timer is programmed from the MENU The timer button is only used to activate deactivate the function ...

Page 40: ...ions from the techni cian Therefore we do not report the complete explana tion in this document DISPLAY INFO SOFTWARE DATA ALARMS PELLET FALL PELLET SENSOR TECHNICAL MENU SET TEMPERATURE The set point digits contain the progressive number of the menu item while the status bar includes the description of the menu item in large letters NOTE Depending on the version the order of the items may vary To...

Page 41: ...s with the and buttons and enter the item with the button After entering the Stand by function the display will show the name of the function on the first line of the status bar and the current value on the second line OFF if deactivated ON if active The and buttons can be used to modify the value from Off function deactivated to On activated and the button can be used to confirm Pressing the butt...

Page 42: ...S PELLET LOADING Allows you to load pellets after the pellet tank has been completely emptied Useful for the technician during the initial start up Available only in the OFF status Any attempt to activate the function in other statuses will not be allowed To access the function from the main menu as indicated in the Menu section above press the MENU button You can scroll the menu items with the an...

Page 43: ... RH shows the start of the time slot Use the and buttons to scroll the time with 1 2 hour steps by moving the cursor and displaying the pre set level Choose the day of the week by scrolling the and buttons you will simultaneously see the programme for that day and confirm with the button OK SAVE BUTTON ...

Page 44: ...can be used to modify the temperature levels OFF T1 and T2 or the power levels OFF P1 and P5 After reaching 23 30 you must go backwards If you shift by pressing and holding the or buttons for more than 2 you copy the previous level onto the next level with a 1 2 h frequency per second The level can be copied also with backward shifts ...

Page 45: ...he main page USER INSTRUCTIONS The copied day of the week flashes and you can shift to the next day using the and buttons USER NOTES The switching on and off of the product can be forced with the timer active by pressing the ON OFF button for 2 Only with the Stand by function active will the product switch off once the set temperature has been reached Confirm with the button ...

Page 46: ... is the lowest temperature T2 the highest Use the and buttons to move to set point T2 setting To access the function from the main menu as indicated in the Menu section above press the MENU button You can scroll the menu items with the and buttons and enter the item with the button Modify the values with the and buttons and confirm with the button Pressing the button automatically takes you to the...

Page 47: ...e MENU button You can scroll the menu items with the and buttons and enter the item with the button After entering the Date Time function the display will show the name of the function on the first line of the status bar and the current value of the first setting 12 24 hours on the second line You can switch from 12 to 24 hours using the and buttons and confirm with the button You reach the AUTO S...

Page 48: ...enu as indicated in the Menu section above press the MENU button You can scroll the menu items with the and buttons and enter the item with the button Modify the language using the and buttons then exit and confirm with the button Pressing the button automatically takes you to the first level The following functions must be taken into account only following indications from the technician Therefor...

Page 49: ...ttons and and confirm with OK button STBY BRIGHTNESS Indicates the backlight percentage of the display be fore entering energy saving mode TIME ON Indicates the time the display remains illuminated STANDBY TIME Indicates the amount of time the display remains illumi nated before entering power saving mode BEEP Allows to enable an acoustic signal when the buttons are pressed OFF if deactivated ON i...

Page 50: ...agnostic meaning of the messages and values and may ask you to read them to him her if you experience problems INSTALLER Pressing the button automatically takes you to the first level To access the function from the main menu as indicated in the Menu section above press the MENU button You can scroll the menu items with the and buttons ...

Page 51: ...only under the guidance of the Technical Assistance Centre Leonardo indicates the target value set and read To be read only under the guidance of the Technical Assistance Centre Fan1 indicates the output voltage To be read only under the guidance of the Technical Assistance Centre Ignition plug spark plug indicates whether the ignition component is on or off Useful in the ignition phase to underst...

Page 52: ...icates the firmware version of the electronic board basic board the firmware version of the control panel the database associated by the Technical Assistance Centres with the products To be read only under the guidance of the Technical Assistance Centre ...

Page 53: ...USER INSTRUCTIONS To access the function from the main menu as indicated in the Menu section above press the MENU button You can scroll the menu items with the and buttons and enter the item with the button Pressing the button automatically takes you to the first level DATA N ACC 236 DATA WORKING HOURS 236 ...

Page 54: ...ian The meaning of the abbreviations is in the dedicated paragraph The alarms are arranged from the most recent to the oldest Exit with the button PELLET SENSOR Allows you to set ON or OFF of the pellet level sensor PELLET FALL Allows to set the auger motor in continuous cycle or in steps To be carried out ONLY UNDER THE GUIDE OF A TECHNICIAN PELLET FALL PELLET FALL CONTINUES SENSOR ...

Page 55: ...ct to seize up Information on how to use these functions is only available to technicians in the appropriate web area After entering the Technical Menu the first item FLAME TYPE will appear You can enter the Flame Type setting using the button while the and buttons can be used to modify the correction value Pressing the button automatically takes you to the first level FLAME TYPE for the TECHNICIA...

Page 56: ...e Pellet Type setting with button and the value can be modified with button and Use the button to exit and return to the Technical Menu In correct installation conditions with the Service Centre parameters appropriately adjusted with quality pellets the pellet load is adjusted MEDIUM HIGH LOW USER INSTRUCTIONS INSTALLER ...

Page 57: ...up to the item PARAMETERS You enter the Parameters with button the first parameter is displayed Scroll through the parameters with and and the value can be modified with buttons and If you entered the Technician Menu with the Installer Password only the Installer parameters appear otherwise all the parameters appear ...

Page 58: ...o activate the speed of the ducting fan at maximum ON OFF NUMBER OF FANS enables or disables the possibility for the end customer to operate the fan if present ROOM INPUT allows to choose which item the end customer reads and adjusts on the Home display It depends on the type of plant PROBE room probe standard in the product THERMOSTAT enables the thermostat which can be installed in place of the ...

Page 59: ...59 ENGLISH SET TEMPERATURE Allows the correction of the reading of some temperature probes To be carried out ONLY UN DER THE GUIDE OF A TECHNICIAN ADJ ROOM1 ADJ TEMP RADIO USER INSTRUCTIONS INSTALLER ...

Page 60: ...cuum up hot ash this damages the vacuum cleaner and may cause a fire DAILY MAINTENANCE figure 1 facing page This must be done with the appliance switched off and cold Open the door and extract the two part grate 1 and ash drawer Empty out the ash drawer 2 and grate into a non flammable container Vacuum out the interior of the hearth the bed and the compartment around the grate into which the ash f...

Page 61: ...61 ENGLISH MAINTENANCE 4 2 1 USER Position correct Position incorrect deflector Cross section ...

Page 62: ...amin of all liability for any resulting damages This also invalidates the warranty on the basis of tampering Do not make unauthorised modifi cations DISPOSAL At the end of its service life dispose of the product as required by regulations REPAIRS To be performed only by Edilkamin technical assistance centres authorised distributors The names of Edilkamin technical assistance centres TAC and offi c...

Page 63: ...t cleaned regularly as explained above ignition may involve a slight detonation If white smoke forms in the combustion chamber for a long time disconnect the mains supply and wait 30 minutes before opening the door and emptying out the burning pot alternating SHUTDOWN MESSAGES AND THEIR SOLUTIONS In case of an alarm an alarm code will appear instead of the room temperature While the product switch...

Page 64: ...here are pellets in the tank and burning pot Try switching it on with a solid ecological igniter contact the technician beforehand and follow the instructions of the igniter supplier very carefully The operation must be regarded purely as a trial under the technician s guidance A05 Shutdown due to air flow rate sensor breakage Contact the technician A06 displays when the logic board determines tha...

Page 65: ...UTION A12 Room temperature probe failure The product is operating in manual mode Contact the technician A14 Ducting room temperature probe if present fault The product is operating in manual mode Contact the technician A20 Gearmotor fault switch off Contact the technician ...

Page 66: ...f operation The product is working but it must be serviced by an authorised Edilkamin technician LACK OF COMMUNICATION In case of a prolonged lack of communication between the stove and the remote control the Bluetooth transmission icon will disappear as well as the icons transmitted by the circuit board to the remote control Only the room temperature and the time will remain visible The Wi Fi tra...

Page 67: ...el sensor is installed and has been activated When the level sensor intervenes the circuit board emits a single beep in any switch on or work status and the moving reserve symbol will appear on the display The arrows will light up in sequence to signal the need for pellet loading The ignition frequency is roughly 0 5 seconds ...

Page 68: ...t be restarted After reloading the pellets the stove must be restarted manually If the pellets are reloaded and there is an ignition request coming from the timer the stove will restart If the sensor intervenes with the stove OFF or in Initial Cleaning mode following manual emptying of the tank the final symbol will immediately appear and the stove cannot be switched on during the ignition phase t...

Page 69: ...69 ENGLISH ...

Page 70: ...70 ENGLISH ...

Page 71: ...71 ENGLISH ...

Page 72: ...cod 942422 GB 05 22 B w w w e d i l k a m i n c o m 942422 GB The names of Edilkamin offi cial authorised technical assistance centres TAC and distributors are available ONLY at www edilkamin com ...

Reviews: