- 36
-
ENGLISH
GENERAL INFORMATION
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by quali
¿
ed personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
3) In case of problems with the electrical grid, consult an electrician to evaluate the installation of a UPS of at least 800
Vac. Power variations greater than 10% can cause problems for the product.
The above data are indicative and are those resulting during certi
¿
cation on the part of the noti
¿
ed body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
SAFETY DEVICES
• THERMOCOUPLE:
Placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on de
¿
ned parameters.
• VACUUM GAUGE:
Positioned on the smoke extractor, which detects the vacuum value (compared to the installation environment) in the combustion
chamber.
• SAFETY THERMOSTAT:
Trips when the temperature inside the stove is too high. It stops pellet loading, causing the stove to go out.
ELECTRICAL CHARACTERISTICS
Power supply
230 Vac +/- 10% 50 Hz
Average power consumption
120 - 150 W
Power consumption during ignition
400 W
Remote control frequency
2,4 GHz
Protection on electronic circuit board
T2A, 250 Vac, 5x20 Fuse
THERMO TECHNICAL CHARACTERISTICS
according to EN 14785
(for other values, see DoP on page 35)
Nominal power
Reduced power
Thermal power output
8
2,5
kW
Yield / Ef
¿
ciency
91,5
92,5
%
Emissions CO 13% O
2
0,013
0,051
%
Fume temperature
133
80
°C
Fuel consumption
1,8
0,6
kg/h
Hopper capacity
15
kg
Draught
12 - 5
10 - 3
Pa
Autonomy
7
20
hours
Heatable volume *
210
m
3
Smoke outlet pipe diameter (male)
80
mm
Air intake pipe diameter (male)
40
mm
Weight including packaging (steel/ceramic/ollare stone)
178/197/202
kg
TECHNICAL DATA FOR SIZING THE FLUE
which must, in any case, comply with the guidelines of
this sheet and the installation rules for each product
Nominal power
Reduced power
Thermal power output
8
2,5
kW
Temperature of fumes on exit from the discharge pipe
160
96
°C
Minimum draught
0 - 5
Pa
Fume
À
ow capacity
5,7
3,2
g/s
*
The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and subse-
quent changes together with an expected heat output of 33 Kcal/m³ per hour.