MMU-16LE
SmartMonitor
Operations Manual
Eberle Design Inc.
Page 36
PPLT5 Arrow Suppression Channel Groups
Phase
Type 16
Type 12
Red, Yellow, & Green Arrow
1, 3, 5, 7
1, 3, 5, 7
Yellow & Green Ball
13, 14, 15, 16
9, 10, 11, 12
This screen enables each channel pair for PPLT Arrow Suppression monitoring. If a
channel pair is not enabled, both associated channels operate in a normal fashion.
6.4 SET-UP WIZARD
Menu Path: MENU / SET-UP WIZARD
Menu Path: MENU / SET VIEW CONFIG / SET-UP WIZARD
The built-in Set-up Wizard configures the monitor enhanced-feature programming using a
series of simple intersection related questions. It allows a technician to accurately and
completely program the MMU-16LE
SmartMonitor
®
enhanced functions without the need
for understanding the complexities of monitor enhanced configuration parameters.
A channel is described as “OTHER” in the Wizard process until it has been assigned to a
UNUSED, PED, VEH+PED, or PP-TURN function.
6.4.1 UNUSED CHANNELS
This step selects the channels of the MMU-16LE
SmartMonitor
®
that are not connected to a
load switch, that is, unused. This selection can eliminate the need to connect the Red input
of an unused channel to AC+. The NEXT button moves the
▼
symbol to the next channel
number. The SELECT button will toggle from the OTHER state to the UNUSED state. A
channel that is selected for UNUSED is indicated by the
and
and
icons
illuminated.
Designating a channel as UNUSED does not affect the Conflict programming on the
Program Card.
When all UNUSED channels have been selected, the EXIT button will display the
navigation choices of NEXT, CANCEL, and EDIT. The NEXT choice continues the Wizard
operation with the next programming step. The CANCEL choice will exit from the Wizard
operation with no changes to the configuration data base. The EDIT choice will return to the
Unused Channels step.
6.4.2 PEDESTRIAN CHANNELS
This step selects the channels of the MMU-16LE
SmartMonitor
®
that are connected to a
pedestrian load switch that drives the Walk and Don’t Walk signal display.
In Nema TS-2
Type 16 mode, the Wizard will ask if the Don’t Walk signal is to be monitored. Answering
YES will configure the MMU-16LE
SmartMonitor
®
to respond to a Red Fail or Dual
Indication (R+G) fault if the Don’t Walk signal fails.
In Nema TS-1 Type 12 operation, this step is not required as the Walk input is
programmed to the associated vehicle monitor channel (R, Y, G, W).
The NEXT button moves the
▼
symbol to the next channel number. The SELECT button
will toggle from the OTHER state to the PED state. A channel that is selected for PED is
indicated by the
(and
) icons illuminated.
When all PED channels have been selected, the EXIT button will display the navigation
choices of NEXT, CANCEL, and EDIT. The NEXT choice continues the Wizard operation
with the next programming step. The CANCEL choice will exit from the Wizard operation
with no changes to the configuration data base. The EDIT choice will return to the
Pedestrian Channels step.