MMU-16LE
SmartMonitor
Operations Manual
Eberle Design Inc.
Page 25
Section 4
ECcom Interface
4.1 EDI ECCOM MONITOR REPORTS
The EDI
ECcom
software package (
Version 3.5.8 or greater is required
) interfaces a
Computer or System to the MMU-16LE. The
ECcom
program will display the Status (S),
Previous Fault (PF) event log, AC Line (AC) event log, Manual Reset (MR) event log,
Configuration (CF) event log, and Signal Sequence logs. All events are time stamped with
the time and date of the event.
Operation of the
ECcom
software package is described in
EDI ECcom Software
Operations Manual
and will not be covered in this manual. The EDI ECcom software is
available at no charge from the EDI web site at
www.EDItraffic.com
.
4.1.1 GENERAL DATA
Monitor ID#: a four digit (0000-9999) ID number may be assigned to the monitor.
Monitor Name: a thirty character name may be assigned to the monitor.
Time and Date: each event is marked with the time and date of occurrence.
Event Number
4.1.2 CURRENT STATUS (S)
: identifies the record number in the log. Event #1 is the most recent event.
Fault Type: the fault type description.
Field Status: the current or latched RYGW field status and RMS voltages.
Cabinet Temperature: the current or latched temperature if the monitor.
AC Line Voltage: the current or latched AC Line voltage and frequency.
Control Input Status
4.1.3 PREVIOUS FAULT (PF) EVENT LOG
: the current or latched state and RMS voltage of the Red Enable input
and Load Switch Flash bit.
Fault Type: the fault type description.
Field Status: the latched field status, RMS voltages, and fault channel status at the time of
the fault.
Cabinet Temperature: the latched temperature at the time of the fault.
AC Line Voltage: the AC Line voltage and frequency at the time of the fault.
Control Input Status
4.1.4 AC LINE (AC) EVENT LOG
: the latched state and RMS voltage of the Red Enable input and Load
Switch Flash bit.
Event Type: describes the type of AC Line event that occurred.
Power-up: AC on, monitor performed a cold start
Brown-out: AC Line < drop-out level
Restore: AC restored from AC brown-out or AC interruption, no cold start
AC Line Voltage
: the AC Line voltage at the time of the event.