MMU-16LE
SmartMonitor
Operations Manual
Eberle Design Inc.
Page 29
5.2.2.4 CLEAR LOGS
This menu category provides a means to clear the following logs:
Previous Failure (PF) log
AC Line (AC) event log
Monitor Reset (MR) log
Configuration (CF) log
The ALL selection will clear all four event logs.
5.2.2.5 SET CLOCK
The built-in time of day and date clock can be set from this menu item. Note that in Type 16
mode, the Controller Unit synchronizes the clock of the MMU-16LE
SmartMonitor
®
once per
second via Port 1 SDLC communications. The day and date clock will automatically adjust
for Daylight Savings time. The week and month that this occurs can be programmed via the
ECcom interface (see
EDI ECcom Software Operations Manual
).
- WARNING -
AFTER RUNNING THE SET-UP WIZARD ALL PARAMETERS SHOULD BE
REVIEWED FOR CORRECTNESS AND CONSISTENCY WITH THE CABINET
PROGRAMMING AND INTERSECTION GEOMETRY.
SOME CHANGES TO THE WIZARD RESULTS MAY BE REQUIRED DEPENDING
ON CABINET WIRING OR OTHER CONSIDERATIONS.