background image

PRODUCT MANUAL 

PROTOCOL FOR NUMERIC DISPLAYS 

ASCII 

CODE 

 

VALUE 

(Decimal) 

FUNCTION 

STX 

‘Start  of  text’,  also  known  as  a  ‘control  B’,  this 
character must be the first character of each message 
 

AD1 
AD2

 

48-57 
48-57 

These two ASCII decimal digits represent the address 
of the display as set on the display.  See appendix C 
for address setting information 
 

DATA 

48-57 

Numeric value to be displayed in ASCII decimal digits.  
It  is  also  permissible  to  include  space  characters 
(character  value  32  decimal),  minus  sign  characters 
(character  value  45  decimal),  and  one  decimal  point 
character (character value  46 decimal) with the digits. 
 

ETX 

‘End of text’, also known as a control C, this character 
must be the last character of each message 

Example:

 

To set the display that has an address of ‘01’ to a value 

of “123456”, the following 

<^B>011234<^C> 

NOTE: the <>’s not to be included in the message. 

 

Or from a terminal program such as PCPLUS, Hyper-

terminal,  or  a  TELNET  screen  if  the  display 
has the Ethernet Option. 

 
The character sequence to be sent will be: 
 

‘Ctrl+B’  “01”  “1234”  ‘Ctrl+C’  (a  total  of  eight 
characters) 

 

The leading zeros will remain blank in all cases. 

 

 
 
 
 
 
 

135 South Church Street 

 

Unit A 

 

Addison, Ill. 60101 

 

Attn:  Repair department 

 
Our telephone number is: 
 

(630) 628-0658 

Our FAX number is: 
 

(630) 628-0936 