2018KCL(ip) SERIES SIGNAL MONITOR
OPERATIONS MANUAL
Eberle Design Inc.
Page 20
Green-Yellow Dual Enable:
Ch: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
X X X X X X X X X X X X X X X X . X
Yellow-Red Dual Enable:
Ch: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
X X X X X X X X X X X X X X X X . X
Green-Red Dual Enable:
Ch: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
X X X X X X X X X X X X . . . . . X
Clearance Enables (X=Enable):
Minimum Yellow Clearance Enable:
Ch: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
X X X X X X X X . . . . . . . . . .
Minimum Yellow Plus Red Clearance Enable:
Ch: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
X X X X X X X X X X X X X X X X . .
Yellow Disable (X=Disable):
Ch: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
. . . . . . . . . . . . . . . . . .
Unit Data:
Minimum Flash = 6 seconds
Watchdog Timing = 1 second
Watchdog Clear on PU = DISABLED
Red Cable Fault = ENABLED
Recurrent Pulse = ENABLED
SF#1 Polarity = NORMAL
Red Fail Fault Timing = 1200-1500 ms
LEDguard Thresholds = ENABLED
Dual Indication Fault Timing = 350-500 ms
AC Line Brownout = 98 +/- 2 Vrms
Pin EE Polarity = NORMAL
Config Change Fault = ENABLED
Flashing Yellow Arrows = <none>
Configuration Check Value = 5355 (0x14EB)
3.3 SIGNAL SEQUENCE EVENT LOG
The Signal Sequence event log graphically displays all signal states and Red Enable state
for up 30 seconds prior to the 2018KCL
fault trigger for the most recent five (5) Previous
Fault (PF) events.