background image

EdgeMarc 4610W Network Services Gateway Installation Guide 

 

 

Analog Voice 

Combinations of FXS and FXO ports are available on selected models. The FXO ports can 
be connected to PSTN for failover condition. Regular telephones or key systems can be 
connected to FXS ports. 

 

Security 

A stateful packet inspection firewall is used in combination with a voice over IP (VoIP) 
application layer gateway to provide comprehensive “media-aware” security. The 4610W 
also supports IPSec for secure site-to-site networking. 

 

VoIP  

The 4610W resolves NAT/FW traversal problems for SIP, MGCP and H.323 traffic. It 
allows a single public IP address to be used for multiple VoIP clients. VoIP survivability is 
also provided so that local SIP PSTN gateways are available for inbound and outbound 
calling during WAN link failures.  

 

Quality of Service  

The 4610W maximizes WAN link utilization while optimizing voice quality using 
prioritization and shaping.  

 

Call Quality Monitoring  

The 4610W provides passive call quality monitoring statistics for each VoIP call to enforce 
SLAs and resolve networking problems that negatively affect call quality.  

 

Future-proof Scalability  

The 4610W is a powerful, flexible platform that can be deployed initially as a low-cost WAN 
access router and then licensed through software for more advanced VoIP features and 
increased call performance. It is the ideal platform for service providers offering DIA, 
hosted VoIP and managed security services or enterprises migrating to converged voice 
and data networks. 

 

Power over Ethernet 
 

For selected models, the 4610W provides integrated power management and greater 
reliability through the transfer of electrical power, along with data, to remote devices over 
an Ethernet network.

 

 

Summary of Contents for 4610W

Page 1: ...Page 1 of 21 4610W Network Services Gateway Hardware Installation Guide Version 1 0 EWN015 05 B001 ...

Page 2: ...Canada technical specifications were met It does not imply that Industry Canada approved the equipment Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above condition...

Page 3: ...Getting Started 9 Physical Installation 9 Required Tools and Materials 9 Desktop Installation 10 Rack Mount Installation 10 Connecting the Power and Cables 10 Administration 11 Specifications 13 Warranty Information 14 Hardware Warranty 14 Certification and Compliance 15 WIRELESS LAN 15 FCC PART 68 NOTICE 15 INDUSTRY CANADA IC NOTICE 17 ...

Page 4: ...tion Denoted with an exclamation point icon cautions indicate situations in which proper procedures must be followed to avoid the risk of data loss or equipment damage Warning Denoted with a lightening bolt symbol warnings indicate situations in which proper procedures must be followed to avoid the risk of bodily injury Contact and Support Information Chapter or Appendix Description Chapter 1 Over...

Page 5: ...rthwestern Parkway Santa Clara CA 95051 http www edgewaternetworks com Phone 1 408 351 7200 General Email info edgwaternetworks com Sales Email sales edgewaternetworks com Edgewater Networks Inc Technical Assistance Center Phone 1 408 351 7200 ext 2 Support Email support edgewaternetworks com ...

Page 6: ...o HDLC cHDLC PPP MLPPP MLPPPoFR Frame Relay On board RJ 48 connector for easy direct connection T1 E1 framer and transceiver B8ZS HDB3 zero suppression Response to Inband Loop codes ANSI Manual payload loop through the GUI External transmit clock input and receive clock output headers Timing internal or external loop times from the network Provides long haul CSU or short haul DSU signaling Meets F...

Page 7: ...utbound calling during WAN link failures Quality of Service The 4610W maximizes WAN link utilization while optimizing voice quality using prioritization and shaping Call Quality Monitoring The 4610W provides passive call quality monitoring statistics for each VoIP call to enforce SLAs and resolve networking problems that negatively affect call quality Future proof Scalability The 4610W is a powerf...

Page 8: ...ents oversubscription of priority queue Security Stateful packet inspection firewall VoIP aware firewall dynamically provisioning and closing of UDP ports used for VoIP calls IPSec 3DES SHA 1 NAT PAT server that hides enterprise LAN topology Passive Call Quality Monitoring Per call statistics that include Mean Opinion Score MOS average and minimum jitter latency and packet loss Alarms for poor MOS...

Page 9: ...he factory default settings This will reset all passwords and erase all prior configurations The default LAN address will be set to 192 168 1 1 C Erase Button Caution Using the Erase button as outlined above means any configuration made to the 4610W will be lost Additionally the VoIP ALG registration code must be re entered in the 4610W Erasing the configuration means that IP phones installed behi...

Page 10: ...en connecting the 4600 PoE to an existing T1 E1 WAN router cable or xDSL modem I V 90 Dial In Console Used to establish a local console session with the 4610W using a PSTN connection The connection is established by calling into the 4610W from a dial up modem The web interface is not available using this option Off Indicates that the system is not on or the T1 cble is not connected Solid Green Ind...

Page 11: ...0 terminal or emulation program The cable required is a straight through 8 wire cable The serial port uses a baud rate of 9600 8 data bits 1 stop bit and no parity This port is used for debug or local diagnostic purposes only Primary configuration of the 4610W is performed from a web browser as covered in VOS User Manual B Power Connector Accepts the plug from the supplied power cord to connect th...

Page 12: ...d by the manufacturer Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connectio...

Page 13: ...with screws Connecting the Power and Cables The 4610W comes with an AC power cord and power adapter for connecting the unit to the AC outlet Warning Always connect the AC power cord to an AC outlet suitable for the power supply that came with the unit in order to reduce the risk of damage to it Connect one end of the AC power cord to the power adapter and the other one to the AC outlet Connect plu...

Page 14: ...68 1 1 for the LAN port To connect to the 4610W device follow these steps 1 Assign static IP address 192 168 1 2 with subnet 255 255 255 0 to a PC 2 Connect the PC to LAN port 4 of the 4610W device 3 Launch a web browser on the PC and enter the URL string 192 168 1 1 Press Return The login window appears 4 Enter the username root and the password default to log into the system The initial 4610W de...

Page 15: ...k Services Gateway Installation Guide 12 5 Select Network and start configuring the 4610W device Note For secure network management change the default user name and password as described in the VOS for EdgeMarc User Manual ...

Page 16: ...l Ports 1xRS 232 Dimensions Height 1 75 44 45 mm Width 16 93 430 02 mm Depth 13 19 335 03 mm Weight 6 5 lb 2 95 kg Power 48V 3 5A external plug pack Total Power Budget up to 112W 8W power band Warranty 1 Year Environmental Operating Temperature 5 to 40 C Humidity 20 to 80 non condensing For the latest information please visit the following URL http www edgewaternetworks com and look for EdgeMarc P...

Page 17: ...conforming Hardware from Edgewater and return the nonconforming Hardware to Edgewater s designated repair facility freight prepaid with a statement describing the nonconformity Edgewater s exclusive obligations with respect to nonconforming Hardware shall be at Edgewater s option to advance replace such Hardware if it is determined to be defective or to refund to End user the purchase price paid f...

Page 18: ...harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice is not practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilitie...

Page 19: ...commission public service commission or corporation commission for information If your home has specially wired alarm equipment connected to the telephone line ensure the installation of Model 4610W equipment does not disable your alarm equipment If you have questions about what will disable alarm equipment consult your telephone company or a qualified installer ...

Page 20: ...f connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by a user to this equipment or equipment malfunctions may give the telephone communications company cause to request the user ...

Page 21: ...Edgewater Networks Inc 2895 Northwestern Parkway Santa Clara CA 95051 Phone 408 351 7200 info edgewaternetworks com Copyright 2010 Edgewater Networks Inc All rights reserved Converged Networking Simplified ...

Reviews: