3-5 

 

3.0: 

 

SETUP AND ACTIVATION 

The setup of a particular system depends upon the configuration. However, the following general 

guidelines may be used for most systems. Further instructions can be found in the product's hardware 

and Discover software manuals.  

3.1

 

Unpacking and Inspecting 

Carefully unpack the Starmux IV and check the packing list to ensure that all items are present. If any items 

are missing, report it to 

E

DGE

T

ECH 

C

USTOMER 

S

ERVICE

. Likewise, if any items have been damaged during 

shipping, do not install them. Instead, contact EdgeTech for further instructions. 

Save the original packaging that the system came with, as these containers can and should be used when 

the system is not used for extended periods of time. 

3.2

 

Installing the Starmux IV 

The  Starmux IV should be located and set up in a dry, sheltered environment that is protected from 

weather and water spray. All configurations  require an environment where the temperature is 

consistently between 0–45°C (32–113°F) and humidity no greater than 90%. Avoid areas of direct sunlight, 

especially in tropical environments, as heat buildup could damage the equipment, and glare could hinder 

the user's ability to see the LCD and status indicators.  

The Starmux IV should be physically located in an area that provides unimpeded access and is within the 

physical and electrical limits of the network, device, tow cabling, and power source it is attached to. Please 

avoid severe bends, particularly with the tow cable. The Starmux IV should also be located in a place that 

allows users to communicate directly with the deck crew handling the towfish.  

If  mounting  the  Starmux IV in  a 19-inch rack, ensure that there is ample room behind the rack for 

connecting the cables. Support the rack's components using appropriate mounting brackets and secure 

the front panels using standard 19-inch rack front panel mounting hardware. A drawing with dimensions 

and weights can be found in the 

M

ECHANICAL 

D

RAWINGS

 section of this manual. 

3.3

 

Starmux IV Control, Indicator, and Connection Configurations 

Starmux IV configuration front and rear panel pictures with marked control, indicator, and connections 

are provided below, along with tables describing them. 

Summary of Contents for STARMUX IV

Page 1: ...EdgeTech 4 Little Brook Road West Wareham MA 02576 Tel 508 291 0057 Fax 508 291 2491 www EdgeTech com STARMUX IV U S E R H A R D W A R E M A N U A L 0023786_REV_C August 2022...

Page 2: ...re issued in strict confidence on the condition that they not be copied reprinted or disclosed to a third party either wholly or in part without the prior written consent of EdgeTech Any reproduction...

Page 3: ...xtreme care should be taken when handling them Standard handling precautions involve using anti static protection materials and grounding straps for personnel WARNING High voltage may be present in al...

Page 4: ...if applicable At times however direct replacements may not exist When this happens EdgeTech will provide the necessary drivers with the replacement part if applicable EdgeTech may also change certain...

Page 5: ...ject to change and should be used for reference only Liability EdgeTech has made every effort to document the Starmux IV in this manual accurately and completely However EdgeTech assumes no liability...

Page 6: ...he items have not been misused or abused in any manner nor have repairs been attempted without EdgeTech Customer Service s approval iii Written notice of the failure within the warranty period is forw...

Page 7: ...tly to the customer New software releases consist of the following Software enhancements that are not on the price list Software fixes and changes Product integration Documentation updates to online h...

Page 8: ...ply only to the material being returned from outside the continental United States Follow them carefully to prevent delays and additional costs 1 All shipments must be accompanied by three copies of y...

Page 9: ...as each carton s contents are clearly numbered and identified on the invoice 4 Small items can be shipped prepaid directly to EdgeTech by FedEx DHL UPS Airborne etc 5 If the equipment is the property...

Page 10: ...roducts We encourage you to contact EdgeTech Customer Service to offer any suggestions or to request technical support NOTE Please have your system Serial Number available when contacting Customer Ser...

Page 11: ...plications for over 50 years The company has responded to the scientific naval and offshore communities needs by providing equipment such as sub bottom profilers side scan sonar acoustic releases USBL...

Page 12: ...RES xiv LIST OF TABLES xv 1 0 OVERVIEW 1 1 1 1 Applications 1 1 2 0 SPECIFICATIONS 2 2 2 1 Mechanical Drawings 2 3 3 0 SETUP AND ACTIVATION 3 5 3 1 Unpacking and Inspecting 3 5 3 2 Installing the Star...

Page 13: ...xiii 3 4 4 Connecting a FSK Trigger 3 13 3 5 Activating the Unit 3 14 4 0 MAINTENANCE 4 15 5 0 TROUBLESHOOTING 5 16...

Page 14: ...nd Connections 3 6 Figure 3 2 Labeled Front Panels of Starmux IV Rackmount 3 8 Figure 3 3 Labeled Rear Panels of Starmux IV Rackmount 3 9 Figure 3 4 Starmux IV and Optional EdgeTech Computer Ethernet...

Page 15: ...1 Starmux IV Front and Rear Panel Controls Indicators and Connection Descriptions 3 7 Table 3 2 EdgeTech 2U Computer Controls Indicators and Connections Descriptions 3 10 Table 3 3 Reserved IP Number...

Page 16: ...oting tips It should be used with EdgeTech Discover Software and EdgeTech Hardware Manuals to support your EdgeTech system Download links for the latest manual for this product and others can be found...

Page 17: ...Kg 32 lb 70 3 kg 155 lb Operating Temp 0 45 C 32 113 F 0 45 C 32 113 F Storage Temp 10 60 C 14 140 F 10 60 C 14 140 F Operating relative humidity 5 90 non condensing 5 90 non condensing Non operating...

Page 18: ...2 3 2 1 Mechanical Drawings Figure 2 1 Starmux IV ICD 0022246...

Page 19: ...2 4 Figure 2 2 Starmux IV in 6U Case ICD...

Page 20: ...no greater than 90 Avoid areas of direct sunlight especially in tropical environments as heat buildup could damage the equipment and glare could hinder the user s ability to see the LCD and status in...

Page 21: ...and Rear Panel Controls Indicators and Connections Digital Current Meter Display LAN LINK Fish Power Cable Fault Indicator Lights Starmux Power Switch Sea Cable Connector Data Ethernet Port Grounding...

Page 22: ...PANEL STARMUX IV Line VAC Connector Connection for the AC power cord Line Power Switch Rocker switch Switches AC power to the POWER switch on the front panel of the Starmux Digital Link AC Fuse 5A Fu...

Page 23: ...Labeled Front Panels of Starmux IV Rackmount Digital Current Meter Display Starmux Power Switch DVD RW Drive LAN LINK Fish Power Cable Fault Indicator Lights USB Connectors CPU Power and Reset Power I...

Page 24: ...r Panels of Starmux IV Rackmount USB Connectors AC Fuse Sea Cable Connector Data Ethernet Connector Grounding Lug Power Switch Power Switch Ethernet Connectors Video Card PC COM 1 PC COM 3 FSK Sync Co...

Page 25: ...Video card Video card with 4 Mini DP Display Connectors Provides video display to the monitor COM 1 NAV Connector DB 9 female connector RS 232 serial port that connects to the navigation system when t...

Page 26: ...ional displays 3 4 1 Connecting the Starmux IV to a Computer The Starmux IV Topside digital link and computer are physically connected by an Ethernet cable plugged into the Starmux s rear panel Data E...

Page 27: ...ault Gateway The Obtain DNS Server Address Automatically radio button is automatically selected by Windows so the Preferred DNS Server and Alternative DNS Server fields do not need to be populated SYS...

Page 28: ...ure 3 6 Starmux IV Rear Panel Tow Cable Connector 3 4 4 Connecting a FSK Trigger The Starmux IV comes standard with a FSK Frequency Shift Keyed Trigger BNC connection on the rear panel which is typica...

Page 29: ...e power switch on the rear panel of the Starmux IV Digital Link This switch can be left in the ON position at all times if desired 3 Turn ON the power switch on the front panel 4 The PWR light should...

Page 30: ...ust out with canned air may prevent overheating and aid in extending the unit s life Beyond this no maintenance is required WARNING Do not open the Starmux IV without first disconnecting the AC power...

Page 31: ...al link and the external topside processor Check the LAN connections between the STARMUX IV unit and the topside processor The indicator is dark Open the unit and check the indicator LED and wiring Th...

Page 32: ...ternal topside Check that under Configuration pull down Network the displayed address is 192 9 0 101 with Port set to 1700 The tow vehicle is faulty Verify the tow vehicle using a different digital li...