SECTION 2:
SPECIFICATIONS
2-2
Acoustic Specifications
The acoustic specifications for the 8242XS unit are described in the following sub-sections.
SPECIFICATIONS
VALUE
Transmit source level
192 dB re 1
µ
Pascal-meter
Command codes
BACS commands
Transponder sensitivity
-80 dB re 1
µ
Pascal
Transponder SNR
> or = 44 dB re root Hz for jitter < +/-
0.5 milliseconds (3 σT).
Jitter =+/- 0.1 milliseconds for noise-free field
Interrogate frequency
11 kHz (standard unit)
Post filter bandwidth
330 Hz
Minimum interrogate pulse width
5 milliseconds
Reply frequency
Default 12 kHz
Transmit/Reply source level
192 dB re 1
µ
Pascal-meter
Reply pulse width
10 milliseconds (standard unit)
Turnaround time delay
12.5 milliseconds (standard unit)
Lockout time
1.0 seconds
Receiver sensitivity
-100 dB re 1
µ
Pascal-meter
Receiver SNR
> or = 36 dB re root Hz
Receiver type
Hard-limited (2000 Hz / 330 Hz bandwidths)
Table 2-2: Acoustic Specifications
BACS Command Structure
The BACS’ command structure consists of two 8-bit words separated by a 5-sec interval. Each word is
comprised of 8 bits from a 16-bit command. The 16-bit command is a 15 bit, 11 block cyclic code with an
overall parity bit appended to the end to form a 16-bit code with a minimum Hamming distance of 4 bits.
Two transitions are required within each word, and no repetitions of words are allowed in a command.
SPECIFICATION
VALUE
Coding
General to 8000 series – Binary FSK
Allowed tone pairs
Six (see
) for full breakdown of pairs
Structure
Two successive 8 bit words with a 5 sec. interval between them.
Each word comprised of 8 bits from a 16 bit command. The 16 bit command is a 15,
11 block cyclic code with an overall parity bit appended to the end to form a 16, 11
code with a minimum Hamming distance of 4 bits.
Additionally, two transitions are required within each word, and no repetitions of
words are allowed in a command.
Pulse width
22 milliseconds
Period
250 milliseconds
Total command time
9 seconds
Total lockout time
14 seconds re beginning
Total command
capacity per tone pair
2,000 or 12,000 commands for six tone pairs
Standard functions
Release, Disable Transponder, Enable Transponder
Table 2-3: BACS Command Structure Specifications
Summary of Contents for 8242XS
Page 18: ......
Page 22: ...SECTION 2 SPECIFICATIONS 2 4 Figure 2 2 ICD 8272 XS Short 0010816 ...
Page 23: ...2 5 Figure 2 3 ICD 8242XS Long 0011329 ...
Page 24: ......
Page 68: ...SECTION 5 MAINTENANCE 5 18 Figure 5 17 8242XS MART Main Sub Assembly 0002737 ...
Page 72: ...SECTION 5 MAINTENANCE 5 22 Figure 5 19 8242XS Acoustic Release Transducer Assembly 0003226 ...
Page 73: ...5 23 Figure 5 20 8242XS Release Mechanism Sub Assembly Page 1 of 2 002780 ...
Page 78: ...APPENDIX A REMOTE RELEASE A 2 Figure A 1 8242XS Remote Release 0018268 ...
Page 80: ...B 2 Figure B 1 8242XS Tandem Kit Drawing 0006657 ...