2-3
BACS Command Coding
BACS command coding is described in the following table:
TONE PAIR NUMBER
“0” (VALUE IN kHz)
“1” (VALUE IN kHz)
1
9.5
9.9
2
9.5
10.3
3
9.5
10.7
4
9.9
10.3
5
9.9
10.7
6
10.3
10.7
Table 2-4: Allowed BACS Tone Pair Breakdown
Standard Command Functions
Functions for the three standard commands are given in the table below:
COMMAND
FUNCTION
ENABLE
Enable Transponder
DISABLE
Disable Transponder
RELEASE
Activate mechanical release
Table 2-5: Standard Command Functions
Environmental Specifications
TEMPERATURE
VALUE
Operating
-10
°
C to +40
°
C (14
°
F to 104
°
F)
Storage (Batteries Removed)
-20
°
C to +85
°
C (-4
°
F to 185
°
F)
Table 2-6: Environmental Specifications—Temperature
Battery Types
SPECIFICATIONS
VALUE
Welded Alkaline pack
2 years & 40,000 replies
Replaceable Alkaline
2 years & 100,000 replies
4 years & 200,000 replies
Replaceable Lithium
4.5 years & 250,000 replies
9 years & 500,000 replies
Table 2-7: Battery Type Specifications
Mechanical Drawings
Mechanical Drawings for the 8242XS are shown below:
Summary of Contents for 8242XS
Page 18: ......
Page 22: ...SECTION 2 SPECIFICATIONS 2 4 Figure 2 2 ICD 8272 XS Short 0010816 ...
Page 23: ...2 5 Figure 2 3 ICD 8242XS Long 0011329 ...
Page 24: ......
Page 68: ...SECTION 5 MAINTENANCE 5 18 Figure 5 17 8242XS MART Main Sub Assembly 0002737 ...
Page 72: ...SECTION 5 MAINTENANCE 5 22 Figure 5 19 8242XS Acoustic Release Transducer Assembly 0003226 ...
Page 73: ...5 23 Figure 5 20 8242XS Release Mechanism Sub Assembly Page 1 of 2 002780 ...
Page 78: ...APPENDIX A REMOTE RELEASE A 2 Figure A 1 8242XS Remote Release 0018268 ...
Page 80: ...B 2 Figure B 1 8242XS Tandem Kit Drawing 0006657 ...