To Operate in Fan Mode: 

 

Use this function only when cooling is not desired, such as for room circulation or to 
exhaust air (remember to open the vent). You can choose any fan speed you prefer. 

 

In Fan mode, the display will show the actual room temperature. 

 

In Fan mode, you cannot adjust the set temperature. 

Energy Saver Feature 

  Press the Energy Saver button to initiate this feature. This feature is available in Auto, 

Cool or Dry modes. 

  In this mode, the fan will continue to run for three (3) minutes after the compressor 

shuts off.  The fan then cycles on for two (2) minutes, at ten (10) minute intervals, until 
the room temperature is above the set temperature at which time the compressor turns 
back on and cooling resumes. 

  The Fan Speed can be adjusted when using this feature. 

Timer (Auto Start/Stop) Feature 

  To initiate the Auto Start program, press the Timer button when the unit is 

off

  To initiate the Auto Stop program, press the Timer button when the unit is 

on

  Press or hold the Left (Decrease) or Right (Increase) button to change the Auto Time by 

½ hour increments up to 10 hours, and then one (1) hour increments up to 24 hours.  

  The selected time will register in five (5) seconds and the system will automatically 

revert back to display the previous temperature setting or room temperature when the 
unit is on. 

  Turning the unit on or off at any time or adjusting the timer setting to 0.0 will cancel the 

Auto Start/Stop program. 
 
 

 

Sleep Feature 

  Press the Sleep button to initiate this feature.   

  In this mode, the selected temperature will increase by 2°F (1°C) 30 minutes after the 

feature is selected.  The temperature will then increase by another 2°F (1°C) after an 
additional 30 minutes. 

  This new temperature will be maintained for six (6) hours before it automatically returns 

to the originally selected temperature.  This ends the Sleep feature and the unit will 
continue to operate as initially programmed. 

  The Sleep feature can be canceled at any time by pressing the Sleep button again. 

  The Sleep feature is only available in Auto or Cool modes. 

Filter Check Feature 

This feature is a reminder to clean the Air Filter for more efficient operation. The LED 
light will illuminate after 250 hours of operation. To reset after cleaning the filter, press 
the Filter Check button and the indicator light will turn off. 
 
 

 

Note: When the unit is powered off, there is no display.  

Summary of Contents for Koldfront CAC10000W

Page 1: ...dow Air Conditioner Owner s Manual For more information on other great EdgeStar and Koldront products on the web go to https www edgestar com To use the EdgeStar self diagnostic tool go to https suppo...

Page 2: ...his unit near flammable gases combustibles or in close proximity to heating appliances During operation do not remove any part of the outside casing Electrical Requirements A 115 volt 103 5 minimum 12...

Page 3: ...hould trip the plug and cut the power to the air conditioner If the plug does not trip and you are able to turn on the unit please contact EdgeStar support DO NOT USE YOUR WINDOW AIR CONDITIONER IF TH...

Page 4: ...PERATIONS 10 Using the Control Panel 10 Digital Display 10 To Turn the Unit On 10 To Change Temperature 11 To Adjust Fan Speeds 11 To Select Operating Mode 11 To Operate in Auto Mode 11 To Operate in...

Page 5: ...ngs label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service...

Page 6: ...2 Parts Identification Side View Front View CAUTION Make sure the drain plug is firmly installed before using the unit to prevent leaking...

Page 7: ...choose one that is near an electrical outlet that will be able to provide sufficient power to your unit See the power requirements listed on the product label printed on the side or the back of your...

Page 8: ...rt brace and test again 2 Measure 8 11 16 from the window jamb and lightly draw a line in pencil NOTE When choosing your window make sure power supply cord is within 6 feet of a grounded 3 prong outle...

Page 9: ...sealing strip on the inner track 5 Securely attach a siding protection board to the side of the house 6 Place the window platform with the platform tab against the inside of the window track Fasten t...

Page 10: ...ng three 8x3 8 screws item 17 in the parts supplies list per channel When fastening the screws start with the top screw and make sure that the curved ends on the long end of the channel face back towa...

Page 11: ...length so that the seal is even with the bottom of the side channel Remove the Front Panel 1 Remove the two 2 front retaining screws from the front frame 2 Gently pull the front out and lift up to rel...

Page 12: ...he window does not fit snugly against the window panel frame it can be secured with screws Using the partially plugged holes in the window panel frame drill 1 8 pilot holes for the screws Secure the w...

Page 13: ...front in the proper location Installing Air Conditioner Into a Casement Window Follow the steps listed below to install the air conditioner into the window 1 Using two 2 or more persons safely lift t...

Page 14: ...ot holes in the side window jambs Secure the side channels using two 8 32x3 4 self threading screws 4 Replace the front panel by reversing the steps in the Remove the Front Panel section Control Panel...

Page 15: ...elected temperature In this mode the fan speed cannot be adjusted It starts automatically at the appropriate speed to reach and maintain the selected temperature most efficiently To Operate in Cool Mo...

Page 16: ...nd then one 1 hour increments up to 24 hours The selected time will register in five 5 seconds and the system will automatically revert back to display the previous temperature setting or room tempera...

Page 17: ...air directional louvers side to side use the center handles as you move side to side Exhaust Control The Exhaust Control allows the air conditioner to either circulate inside air Closed or exhaust air...

Page 18: ...This button is used to enable the timer Press it twice to cancel the programmed Auto Start Start time See Timer Feature for operating details SPEED This button allows you to cycle through the followin...

Page 19: ...l the grove aligns with the lock symbol Note In order for the remote to function properly the distance between the remote and the air conditioner should not exceed 16ft 5m Electronics may interfere wi...

Page 20: ...ing the filter with a vacuum Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth da...

Page 21: ...ide Read and follow the guide below to get the best performance and efficiency from your window air conditioner Do not cover the air outlet exhaust while in use Use the timer to operate the unit befor...

Page 22: ...el cold enough Room temperature is below 62 17 Cooling will not occur until room temperature rises above 62 17 Temperature sensor behind the front grill and air filter is touching the cold evaporator...

Page 23: ...ner turns on and off frequently Dirty air filter air restricted Clean air filter Outside temperature is extremely hot Set FAN speed to a Higher setting to push more air through the coils Noise when un...

Page 24: ...duct Casement Window Air Conditioner Model CAC10000W Voltage Frequency 115V 60Hz Cooling Capacity BTUs 10000 Current 8 5A Color White Refrigerant R410A 17 64 oz Timer 24 Hour Dimensions W x D x H 14 1...

Page 25: ...on or commercial use Labor service transportation and shipping charges for the removal and replacement of defective parts beyond the initial 24 month period Products that have been modified to perform...

Reviews: