Line Commands
4-15
4
exec-timeout
This command sets the interval that the system waits until user input is detected.
Use the
no
form to restore the default.
Syntax
exec-timeout
[
seconds
]
no exec-timeout
seconds
- Integer that specifies the timeout interval.
(Range: 0 - 65535 seconds; 0: no timeout)
Default Setting
• CLI: No timeout
• Telnet: 10 minutes
Command Mode
Line Configuration
Command Usage
• If user input is detected within the timeout interval, the session is kept open;
otherwise the session is terminated.
• This command applies to both the local console and Telnet connections.
• The timeout for Telnet cannot be disabled.
• Using the command without specifying a timeout restores the default setting.
Example
To set the timeout to two minutes, enter this command:
password-thresh
This command sets the password intrusion threshold which limits the number of
failed logon attempts. Use the
no
form to remove the threshold value.
Syntax
password-thresh
[
threshold
]
no password-thresh
threshold
- The number of allowed password attempts.
(Range: 1-120; 0: no threshold)
Default Setting
The default value is three attempts.
Command Mode
Line Configuration
Console(config-line)#exec-timeout 120
Console(config-line)#
Summary of Contents for ES3628C
Page 2: ......
Page 4: ...ES3628C F3 1 0 18 E032005 R01 149100005100H...
Page 38: ...Introduction 1 10 1...
Page 48: ...Initial Configuration 2 10 2...
Page 281: ...IP Routing 3 233 3 Web Click Routing Protocol RIP Statistics Figure 3 133 RIP Statistics...
Page 326: ...Configuring the Switch 3 278 3...
Page 652: ...Command Line Interface 4 326 4...
Page 666: ...Glossary Glossary 8...
Page 672: ...Index 6 Index...
Page 673: ......
Page 674: ...ES3628C E032005 R01 149100005100H...