Eddyfi Technologies Inuktun 2-Function Manipulator User Manual Download Page 14

 

2-Function Manipulator 

 

Document: UMDK007857.docm  

Revision: A08 

Created by: 

CWS;PV 

Date: 26 Sep 2019 

IPN: 3044246-A08 

Source Location: C:\ePDM\ISLEng\products\dk-manipulators\manuals\UMDK007857.docm

 

 

Page 14 of 15 

 

U

ser

 M

a

nual

 

Warranty Repairs 

Warranty conditions are specified in the Warranty section. Should any conditions of the 

manufacturer’s 

warranty be breached, the warranty may be considered void. All returned items must be sent prepaid to 
Eddyfi Technologies at the above address. 

Factory Returns To Canada 

Some sub-assemblies of your Eddyfi Technologies product are not field-serviceable and may need to 
return to the factory for repair. Warranty claims must return to the factory for evaluation. 

To return an item for evaluation or repair, first contact Eddyfi Technologies at our toll-free number or e-
mail address. Eddyfi Technologies will supply a Return Merchandise Authorization (RMA) number with 
detailed shipping and customs instructions. Items shipped without an RMA number will be held at Eddyfi 
Technologies until the correct paperwork is completed. If cross-border shipments are not labelled as per 
the instructions, the items may be held by customs and issued additional fees. 

All returned items must be sent prepaid unless other specific arrangements have been made. 

When the product or system is being shipped anywhere by courier or shipping company, it must be 
packaged in the original packaging it was received in. This measure greatly reduces the consequences of 
rough handling and subsequent shipping damage. 

Eddyfi Technologies cannot be held responsible for damages due to improper packaging. Shipping 
damage may have significant impact on repair turnaround times. 

Product/System Drawing Package Availability 

Mechanical assembly and electrical wiring diagram drawing packages for your equipment are available in 
PDF format upon request. Printed copies may also be purchased from Eddyfi Technologies. Contact your 
local sales contact for more information. 

 

 

Summary of Contents for Inuktun 2-Function Manipulator

Page 1: ...2569 Kenworth Road Suite C Nanaimo BC V9T 3M4 CANADA 1 250 729 8080 info eddyfitechnologies com www eddyfitechnologies com INUKTUN 2 FUNCTION MANIPULATOR...

Page 2: ...l 3 Description 3 Specifications 3 Safety 4 System Setup 5 Working Environment 5 Connector Handling 5 Changing Jaw Sets 7 Maintenance 10 Cleaning 10 Cutter Blades 10 Post Deployment 10 Sharpening 10 C...

Page 3: ...t necessarily replace specific regulations codes standards or requirements of others such as government regulations This manual copyright 2019 by Inuktun Services Ltd All rights reserved Description T...

Page 4: ...V Jaw 5 10 18 40 0 2 9 0 63 0 1 7 0 37 17 5 6 9 7 Parallel 11 25 23 50 0 2 8 0 61 0 1 6 0 35 5 7 2 3 7 Sampler 5 10 18 40 0 3 0 0 66 0 1 6 0 36 45ml 1 5oz 7 Min and Max closing forces are at the tip a...

Page 5: ...be thoroughly washed down with fresh water after every use Use only standard line pressures pressure washing may damage o ring seals Connector Handling With regard to system reliability connectors are...

Page 6: ...Document UMDK007857 docm Revision A08 Created by CWS PV Date 26 Sep 2019 IPN 3044246 A08 Source Location C ePDM ISLEng products dk manipulators manuals UMDK007857 docm Page 6 of 15 User Manual FIGURE...

Page 7: ...different operating requirements The jaws are easily interchangeable To uninstall the V Jaw Parallel Jaw and the Sampler follow the steps listed below installation is the opposite of removal 1 Close t...

Page 8: ...jaw assembly from the drive unit by gently sliding it forward off the actuator shaft Note on installation and adjustment for plastic jaw sets Some adjustment may be required for smooth operation Reve...

Page 9: ...event loss of parts FIGURE 5 TRIDENT SCREWS Installation and removal of the Cutter is also like the other jaw sets Once the side plate screws are removed extract the standard end clip from the actuato...

Page 10: ...ure to leave a perfectly straight edge irregularities or loss of perpendicularity could result in compromised cutting ability For replacement blades contact your Eddyfi representative Compensation Oil...

Page 11: ...se Schaeffer s ISO 22 food safe hydraulic oil Failure to top up the oil can result in air inside the housing loss of pressure compensation and failure at depth FIGURE 7 BELLOWS PISTON AND OIL PORT Dis...

Page 12: ...made one of three jaw sets Sampler V or Parallel Jaws may be used instead by doing the following 1 Using one of the jaws fasten the centre actuator end block onto the actuator shaft with the mount cl...

Page 13: ...tly from your local office When ordering parts always make sure to quote the sales order acknowledgement SOA number and or the serial number of the system component in question Inuktun Services Ltd Ca...

Page 14: ...RMA number with detailed shipping and customs instructions Items shipped without an RMA number will be held at Eddyfi Technologies until the correct paperwork is completed If cross border shipments a...

Page 15: ...nection to improperly wired AC receptacles 5 Track belts tethers view ports and other components subject to wear through abrasion are warranted to be free from defects in material and workmanship for...