Eddyfi Technologies Inuktun 2-Function Manipulator User Manual Download Page 10

 

2-Function Manipulator 

 

Document: UMDK007857.docm  

Revision: A08 

Created by: 

CWS;PV 

Date: 26 Sep 2019 

IPN: 3044246-A08 

Source Location: C:\ePDM\ISLEng\products\dk-manipulators\manuals\UMDK007857.docm

 

 

Page 10 of 15 

 

U

ser

 M

a

nual

 

Maintenance 

Cleaning 

In order to ensure the Manipulator functions well, it should always be thoroughly cleaned after every use.  
Always use fresh water at standard line pressure (700kPa/100psi max).  Always make sure to drain any 
water from the bellows port (small hole) on the front of the housing.  Failure to clean properly could result 
in premature corrosion of components. 

Cutter Blades 

Post-Deployment 

The cutter blades are made from specially coated steel that will resist corrosion in salt water. However, 
due to the extremely corrosive nature of seawater on even the noblest materials, the blades should be 
properly cared for after use: 

1.  Cleanse with freshwater after every use. 
2.  Dry the blade and apply machine oil or grease to all surfaces. 

Failure to care for the blade as described above will result in premature degradation. 

Sharpening 

If the cutter blades need to be re-sharpened, they can be sharpened numerous times using standard 
methods.  Always make sure to leave a perfectly straight edge 

– irregularities or loss of perpendicularity 

could result in compromised cutting ability.  For replacement blades contact your Eddyfi representative. 

Compensation Oil 

The Manipulator unit is pressure compensated with light, food safe oil to ensure reliable operation at 
depth. If a new manipulator has been sitting on the shelf for an extended period of time, or has recently 
been shipped via air, it is possible some of this oil may “weep” out of the o-ring grooves.  This can be 
alarming as it will appear as though the unit is leaking; in most cases, though, it is nothing to worry about. 

To verify if there is a leak in the unit, perform the following procedure (this same process should be 
repeated annually to ensure the integrity of the housing seals): 

1.  Wash the Manipulator body with hot soapy water (dish detergent work best) and heat the body up 

to 40°C to 50°C (Approx. 104°F - 122°F). The soap will remove any oil, and the hot water should 
help with moving the oil from the cracks.  

2.  Allow the unit to dry 
3.  Place the dried unit on a facial tissue (or similar) in a warm area; if oil marks or slicks appear on 

the tissue within a few minutes it could indicate a failure of one of the housing seals. Contact your 
customer service representative to arrange for repairs. 

At least once a year, check the quality of the oil by completing the following steps. 

Summary of Contents for Inuktun 2-Function Manipulator

Page 1: ...2569 Kenworth Road Suite C Nanaimo BC V9T 3M4 CANADA 1 250 729 8080 info eddyfitechnologies com www eddyfitechnologies com INUKTUN 2 FUNCTION MANIPULATOR...

Page 2: ...l 3 Description 3 Specifications 3 Safety 4 System Setup 5 Working Environment 5 Connector Handling 5 Changing Jaw Sets 7 Maintenance 10 Cleaning 10 Cutter Blades 10 Post Deployment 10 Sharpening 10 C...

Page 3: ...t necessarily replace specific regulations codes standards or requirements of others such as government regulations This manual copyright 2019 by Inuktun Services Ltd All rights reserved Description T...

Page 4: ...V Jaw 5 10 18 40 0 2 9 0 63 0 1 7 0 37 17 5 6 9 7 Parallel 11 25 23 50 0 2 8 0 61 0 1 6 0 35 5 7 2 3 7 Sampler 5 10 18 40 0 3 0 0 66 0 1 6 0 36 45ml 1 5oz 7 Min and Max closing forces are at the tip a...

Page 5: ...be thoroughly washed down with fresh water after every use Use only standard line pressures pressure washing may damage o ring seals Connector Handling With regard to system reliability connectors are...

Page 6: ...Document UMDK007857 docm Revision A08 Created by CWS PV Date 26 Sep 2019 IPN 3044246 A08 Source Location C ePDM ISLEng products dk manipulators manuals UMDK007857 docm Page 6 of 15 User Manual FIGURE...

Page 7: ...different operating requirements The jaws are easily interchangeable To uninstall the V Jaw Parallel Jaw and the Sampler follow the steps listed below installation is the opposite of removal 1 Close t...

Page 8: ...jaw assembly from the drive unit by gently sliding it forward off the actuator shaft Note on installation and adjustment for plastic jaw sets Some adjustment may be required for smooth operation Reve...

Page 9: ...event loss of parts FIGURE 5 TRIDENT SCREWS Installation and removal of the Cutter is also like the other jaw sets Once the side plate screws are removed extract the standard end clip from the actuato...

Page 10: ...ure to leave a perfectly straight edge irregularities or loss of perpendicularity could result in compromised cutting ability For replacement blades contact your Eddyfi representative Compensation Oil...

Page 11: ...se Schaeffer s ISO 22 food safe hydraulic oil Failure to top up the oil can result in air inside the housing loss of pressure compensation and failure at depth FIGURE 7 BELLOWS PISTON AND OIL PORT Dis...

Page 12: ...made one of three jaw sets Sampler V or Parallel Jaws may be used instead by doing the following 1 Using one of the jaws fasten the centre actuator end block onto the actuator shaft with the mount cl...

Page 13: ...tly from your local office When ordering parts always make sure to quote the sales order acknowledgement SOA number and or the serial number of the system component in question Inuktun Services Ltd Ca...

Page 14: ...RMA number with detailed shipping and customs instructions Items shipped without an RMA number will be held at Eddyfi Technologies until the correct paperwork is completed If cross border shipments a...

Page 15: ...nection to improperly wired AC receptacles 5 Track belts tethers view ports and other components subject to wear through abrasion are warranted to be free from defects in material and workmanship for...

Reviews: