background image

13

12

Power supply should be used  AC 220V/20A above.
Necessarily Grounding is needed for your safety.

Grounding

This product is easy to carry mainly due to the caster attached
At carrying product, push the “locker of a caster” toward “OFF” direction and the caster moves.
The product is too heavy, necessarily more than 2 persons should carry the product. On the condition of loading and
carrying the product, necessarily use the lift-truck.
After installing a product, push “locker of a caster” toward “ON” direction. The caster are fixed, it prevents from the
product’s movement.

The product is too heavy, therefore at the condition of carrying product, 
necessarily more than 2persons carry. If you don't, it makes a product breakage 
and personal injury

On carrying product, segregate the powerplug from the outlet, otherwise it makes an 
electric shock

At the same place, carry and install the product in a short distance, use a caster.
At the caster, a locker is installed, on carrying product, you should unlock the locker 
of a caster.
The caster's locking or unlocking is fixed when you push the “lock(ON)” just like the 
right picture, the caster is locked and otherwise push “OFF” lever, the caster is 
unlocked. After carrying the product, lock the caster.

Lock(ON)

Unlock(OFF)

Unlock(OFF)

Lock(ON)

Product installation should be installed on the hard and balanced floor. At the condition of unbalanced status, a laminating 
quality can be down.

Grounding is necessary for your safety.  If the grounding isn't good, 
a static electricity happens excessively, it can be a main reason of a 
malfunction on operating of a laminator. A malfunction and electric 
leakage can make an electric shock.

Insert the powerplug inside firmly.
If you don't, it makes a fireflame by the overheating.

Upper Heating roller temperature 

indication panel

Shows the setting temperature of Heating 
roller and current temperature.
In the normal condition, setting temperature 
diplays but if you press “Measure indication   
button” of Function button, It shows the 
current temperature. A setting temperature 
change can be modified by pressing  the top 
button upwards or downwards.

This product has a self-detection system for   

overheating. If a heater's temperature rises 
too high, it displays “OH”, in this case you turn 
off the power supply of machine, contact your 
dealer.

Speed Display Window

It displays roller's rotation speed, Variation 
speed is “1~9”. Roller's rotation speed is 
modified by the “Speed setting button” being 
adjusted up or down.

Job Mode Display Window

Can memorize the different working condition 
from “1” to “9”, the displayed number means 
that the working condition of included current 
temp and speed memorized.
Working condition change can be adjusted by 
“Job button”.

Working Mode Display Window

“READY” indicates that a heated roller's temperature has reached the laminating temperature.
When “READY” displays on the control panel, you can start laminating.

Heating Display Window

“WAIT” means that the roller's temperature is not right(temperaute is low) against setting 

temperature. On the condition of “WAIT” displays, if you start laminating, a laminating can’t be 
made. If “WAIT” on display window flickers, a roller's temperature is very high against a setting 
temperature. When “WAIT” display flickers, at that time you start laminating, the laminating 
result can have a crease, curving.

EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500

Summary of Contents for EXCELAM-Q 1100RS

Page 1: ...INATION TECHNOLOGY Before operating the unit please read this manual thoroughly and retain it for future reference www gmp com USER SGUIDE EXCELAM Q 1100RS 1670RS EDNord Istedgade 37A 9000 Aalborg tel...

Page 2: ...ive a serious injury or loss of property WARNING Do not overload a power supply Do not connect or disconnect with wet hands as this will cause an electric shock Make sure plug is in the socket as it c...

Page 3: ...e injury Keep gears and chains free of all materials Do not touch the roller and heating plate with your hand as you could be burnt Warnung Wenn Sie dieses Symbol ignorieren Sie k nnen verletzen und s...

Page 4: ...Sie nicht das Gerat langezeit benutzen ausschalten Sie das Ger t and ziehen Sie den Stecker aus der Steckdose Wenn Sie das Ger t in eine neue Position bewegen ziehen Sie den Stecker aus der Steckdose...

Page 5: ...e of the main device Laminating procedure Laminating guide Product Maintenance Trouble shooting Specification GMP Subsidiaries SURELAMPLUS PCR800DBS 2 5mm T Wrench 1EA 3mm 4mm L Wrench 1EA User Guide...

Page 6: ...trol Panel Safety Cover Roller Pressure Bottom film tension handle Front Panel Power Cable Power Switch Foot Switch Cable Bottom Film Emergency Switch Bottom Film Tension Handle Back Trimmer Pull Roll...

Page 7: ...laminator A malfunction and electric leakage can make an electric shock Insert the powerplug inside firmly If you don t it makes a fireflame by the overheating Upper Heating roller temperature indica...

Page 8: ...ged speed 2 When rollers stop At time of roller s stop if you change the speed only the number is changed Press the Run button if you want to rotate the roller RUN Button Is for the purpose of roller...

Page 9: ...tallation of separator positioned at the end of right left can be made by pulling forwards to arrow direction and then by the back trimmer guide it can be installed After installation if you lay down...

Page 10: ...feed table 5 Install the safety cover 6 Install the pressure plate It is easy to work if you preheat the roller before readiness stage Necessarily film should be passed by sub roller Refer to film loa...

Page 11: ...same as hot laminating stage 2 of sequence 2 6 7 Rewind the film into the rewinder paper pipe 8 It is a readiness for ultra thin film laminating Stage 3 Readiness for laminating Ultra thin film neces...

Page 12: ...control is needed Stage 4 Laminating Is the same as the hot laminating stage 3 Caution at the cold laminating Laminating should be made below 30 It is easy to work when you use the foot switch on cold...

Page 13: ...l 50 80mic 2 3 5mil 100 150mic 4 6mil 175 250mic7 10mil Below 100g Above 100g Below 150g Above 150g Below 300g Above 300g 1mm Temp 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 Speed...

Page 14: ...s symptom caused by high temperature of pulling roller Operate cooling fan Decrease roller temperature Model Name EXCELAM Q 1100RS EXCELAM Q 1670RS Power Requirements Power Consumption Dimensions WxLx...

Page 15: ...nter for Distribution Marketing Service and Training Managing Director S G Ra Sales Director Dieter Georgi http www gmp germany de e mail Management germany m gmp com Sales germany s gmp com Address A...

Reviews: