48
AG114123 Rev. 2
Leveling the System
When installing or moving the system,
you must level the system at
its new location
as explained below. See Figure 4-5 for the location
of the leveling feet in the pedestal.
Step 1. Unplug the power cable from the power conditioner. Leaving one
end of the cable plugged into the Mako CTP, gently coil the
power cable and store it on the shelf in the pedestal.
Step 2. Disconnect the SCSI cable from the PC attached to the Mako CTP.
Leaving the SCSI cable connected to the Mako CTP, gently coil
the power cable and store it on the shelf in the pedestal.
Figure 4-5 Levelling Feet Location
Step 3. Retract all four levelling feet so the system rides on its wheels and
place the system in its new location.
Step 4. Turn all four levelling feet of the platesetter down until they just
touch the floor.
Step 5. Continue to turn leveling feet until the system is level, front to back
and side to side.
LEVELLING FEET
FRONT