AG114123 Rev. 2
13
User Preferences Menu
UNITS OF MEASURE
OPTIONS
ENGLISH
(inches) or
METRIC
(millimeters)
The selected units of measure apply to all numeric measurement
values in various menus.
AUDIO ALERTS
OPTIONS
ENABLED
or
DISABLED
This menu item allows you to disable or to enable the audible
alarms for the following conditions:
Error conditions, Power-up, Image complete
HORIZONTAL MAGNIFICATION
LIMITS
85.00% to 110.00%
Sets the size of the image in the horizontal direction from 85% to
110% of nominal.
VERTICAL MAGNIFICATION
LIMITS
85.00% to 110.00%
Sets the size of the image in the vertical direction from 85% to
110% of nominal.
I
MAGE OFFSET
LIMITS
-0.300”
to
+0.300”
(
-7.62mm
to
+7.62mm
)
The image may be shifted to the left with a negative (-) value, or to
the right with a positive (+) value by up to 0.300 inches. Press
PREV
to access the (+) and (-) sign.