![ECR International R15C Installation, Operation & Maintenance Manual Download Page 43](http://html.mh-extra.com/html/ecr-international/r15c/r15c_installation-operation-and-maintenance-manual_2356109043.webp)
ELECTRICAL SPECIFICATIONS
Power Supply
Volt 1–60
Compressor
Indoor Fan
Motor
Outdoor Fan
Motor
Electric Heat
Unit Electrical Ratings
Volt
Min
RLA
LRA
FLA
Hp
FLA
Hp
Htr
#
Volt
W
HA
TCA
THA
MCA MOCP Plug
115V
104
8
45.6
1.4
0.09
1.6
0.125
N/A
N/A
N/A
N/A
11.0
N/A
13.0
20
HARD
WIRE
208/
230V
197
4
22.2
0.6
0.08
0.71
0.09
0
N/A
N/A
N/A
5.3
N/A
6.3
15
3
208
2454
11.8
12.4
15.5
20
230
3000
13
13.6
17.1
4
208
3271
15.7
16.3
20.4
25
230
4000
17.4
18
22.5
5
208
4089
19.7
20.3
25.3
30
230
5000
21.7
22.3
27.9
265V
240
3.32
18.8
0.67
0.08
0.71
0.9
0
N/A
N/A
N/A
4.7
N/A
5.5
15
3
265
3983
15
15.7
19.6
20
4
265
5310
20
20.7
25.9
30
5
N/A
N/A
N/A
N/A
N/A
N/A
Table 16 R60 - 12,000 BTU Electrical Specifications
Table 17 R60 - 9,000 BTU Electrical Specifications
Power Supply
Volt 1–60
Compressor
Indoor Fan
Motor
Outdoor Fan
Motor
Electric Heat
Unit Electrical Ratings
Volt
Min
RLA
LRA
FLA
Hp
FLA
Hp
Htr
#
Volt
W
HA
TCA
THA
MCA MOCP Plug
208/
230V
197
5.6
29
0.6
0.08
0.71
0.09
0
N/A
N/A
N/A
6.9
N/A
8.3
15
HARD
WIRE
3
208
2454
11.8
12.4
15.5
20
230
3000
13
13.6
17.1
4
208
3271
15.7
16.3
20.4
25
230
4000
17.4
18
22.5
5
208
4089
19.7
20.3
25.3
30
230
5000
21.7
22.3
27.9
265V
240
4.6
20
0.67
0.08
0.71
0.9
0
N/A
N/A
N/A
6.0
N/A
7.1
15
3
265
3983
15
15.7
19.6
20
4
265
5310
20
20.7
25.9
30
5
N/A
N/A
N/A
N/A
N/A
N/A
43
Made in USA