Table 3 R15 C Performance Data
Model
R15
Cooling
Sensible
Heat
Ratio
EER
Indoor Air
Flow
Fresh Air
Inlet
Flow
Shipping
Weight
Btuh (kW)
CFM (L/s)
CFM (L/s)
lbs (Kg)
R_ _C 09
9,000 (2.6)
0.75
8.98
400 (189)
35 (17)
140 (64)
R_ _C 12
11,500 (3.7)
0.70
8.45
400 (189)
35 (17)
140 (64)
R_ _C 15
14,000 (4.1)
0.64
7.92
425 (200)
35 (17)
140 (64)
R_ _C 18
15,500 (4.5)
0.64
7.6
425 (200)
35 (17)
140 (64)
PERFORMANCE DATA
Table 4 R50 C Performance Data
Model
R50
Cooling
Sensible
Heat
Ratio
EER
Indoor Air
Flow
Fresh Air
Inlet
Flow
Shipping
Weight
Btuh (kW)
CFM (L/s)
CFM (L/s)
lbs (Kg)
R_ _C 09
9,000 (2.6)
0.75
8.98
400 (189)
35 (17)
140 (64)
R_ _C 12
11,500 (3.5)
0.70
8.45
400 (189)
35 (17)
140 (64)
R_ _C 15
14,000 (4.5)
0.64
7.92
425 (200)
35 (17)
140 (64)
R_ _C 18
15,500 (4.5)
0.64
7.6
425 (200)
35 (17)
140 (64)
Table 5 R60 C/H Performance Data
Model
R60
Cooling
Sensible
Heat
Ratio
EER
Heat Pump
COP
Indoor Air
Flow
Fresh Air
Inlet
Flow
Shipping
Weight
Btuh (kW)
Btuh (kW)
CFM (L/s)
CFM (L/s)
lbs (Kg)
R_ _C 09
9,000 (2.6)
0.78
8.98
N/A
N/A
400 (189)
35 (17)
140 (64)
R_ _H 09
8,800 (2.6)
8.93
8,100 (2.4)
2.69
400 (189)
R_ _C 12
11,500 (3.5)
0.70
8.45
N/A
N/A
400 (189)
35 (17)
140 (64)
R_ _H 12
11,400 (3.3)
8.37 10,500 (3.1)
2.63
400 (189)
R_ _C 15
14,000 (4.5)
0.64
7.92
N/A
N/A
425 (200)
35 (17)
140 (64)
R_ _H 15
13,300 (3.9)
7.97 12,000 (3.5)
2.59
425 (200)
R_ _C 18
15,500 (4.5)
0.64
7.6
N/A
N/A
425 (200)
35 (17)
140 (64)
Table 6 R65 C Performance Data
Model
R65
Cooling
Sensible
Heat
Ratio
EER
Indoor Air
Flow
Fresh Air
Inlet
Flow
Shipping
Weight
Btuh (kW)
CFM (L/s)
CFM (L/s)
lbs (Kg)
R_ _C 09
9,000 (2.6)
0.78
8.98
425 (200)
35 (17)
140 (64)