ECR International H20I60 Installation, Operation & Maintenance Manual Download Page 12

12

Hot Water Can Scald!

Water heated to temperature for 

clothes washing, dish washing and 

other sanitizing needs can scald and 

cause permanent injury.

Children, elderly, and infirm or 

physically handicapped persons are 

more likely to be permanently injured 

by hot water. Never leave them 

unattended in bathtub or shower. Never 

allow small children to use a hot water 

tap or draw their own bath.
•  If anyone using hot water in the 

building fits the above description, 

or if state laws or local codes 

require certain water temperatures 

at hot water taps, you must take 

special precautions:

•  Use lowest possible temperature 

setting.

•  Install some type of 

tempering device, such as an 

automatic mixing valve, at 

hot water tap or water heater. 

Automatic mixing valve must 

be selected and installed 

according to manufacturer's 

recommendations and 

instructions.

Water passing out of drain valves may 

be extremely hot. To avoid injury:
•  Make sure all connections are tight.
•  Direct water flow away from any 

person.

Pipe Relief Valve 

Discharge to within 

6" of floor, see 
Section III Notes.

Pipe Relief Valve 

Discharge to within 

6" of floor, see 
Section III Notes.

FIGURE 4 - BOILER WATER PIPING WITH ZONE VALVES

FIGURE 3 - BOILER WATER PIPING WITH ZONE CIRCULATORS

Summary of Contents for H20I60

Page 1: ...Company ECR International Inc 2201 Dwyer Avenue Utica NY 13501 web site www ecrinternational com Information and specifications outlined in this manual in effect at the time of printing of this manual...

Page 2: ...can cause personal injury or death Read all instructions including all those contained in component manufacturers manuals before installing starting up operating maintaining or servicing the water hea...

Page 3: ...e gas supplier s instructions or if the supplier is unavailable contact the fire department IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances basic safety precautions to reduce th...

Page 4: ...l based on the expected water usage for the given site The average residence with one shower or more will require a Model 40 or larger The Model 30 should only be considered for residences with minima...

Page 5: ...42 7 1 34 0 26 0 3 4 1 150 100 H2OI50 60 8 0 52 0 22 5 3 4 1 150 110 H20I60 60 8 4 60 0 22 5 3 4 1 150 125 H20I60L 60 7 5 44 0 26 5 3 4 1 150 120 H2OI80 80 8 0 54 0 26 5 1 1 150 140 H2OI115 115 8 9 72...

Page 6: ...215 117 900 10 0 2 8 H2OI50 222 290 177 245 132 800 10 0 3 1 H20I60 240 311 186 257 139 400 10 0 3 2 H20I60L 220 284 166 230 124 500 10 0 2 9 H2OI80 257 328 185 256 138 600 12 0 3 7 H2OI115 309 388 2...

Page 7: ...ne The water heater is controlled with an additional zone valve Select a valve with a low pressure drop and assure minimum flow with adequate pipe sizing B Priority or Non Priority for Hot Water 1 Opt...

Page 8: ...iler system during service 2 Unions Allows for easy locating or removal 3 Vacuum breaker Protects water heater from collapse if a hot tank is valved off to service other components in the system 4 The...

Page 9: ...pen Drain the domestic water system 2 Position the water heater in the final location 3 Connect the cold water supply piping Install piping onto cold inlet connection Connect to cold water supply conn...

Page 10: ...hat uses Zone Valves refer to Figure 3 The water heater connection labeled BOILER SUPPLY should be piped to the boiler supply piping after the air purger and before the space heating circulator Mount...

Page 11: ...11 Figure 2 Typical Mixing Valve Install Figure 1 Domestic Water Piping Pipe Relief Valve Discharge to within 6 of floor see Section III Notes...

Page 12: ...temperatures at hot water taps you must take special precautions Use lowest possible temperature setting Install some type of tempering device such as an automatic mixing valve at hot water tap or wat...

Page 13: ...erature in the water heater If it is set too high the resulting hot water can cause painful scalding with possible serious and permanent injury The temperature at which this occurs varies with a perso...

Page 14: ...ing our ARM 4P Panel Product features include Build in transformer that will support up to 15 zones Transformer has electronic fuse protection 1 to prevent transformer overloading Data Port Terminal f...

Page 15: ...15 BOILER T T BOILER T T BOILER T T...

Page 16: ...er will prevent this problem Symptoms are identical to sediment buildup If repeated flushing does not resolve the problem chemical cleaning may be required Contact a qualified contractor VII Troublesh...

Page 17: ...0 1st HOUR CONTINUOUS GAL HR GAL HR GAL HR GAL HR GAL HR GAL HR RATING RATING Boiler flow 14 gpm Boiler flow 14 gpm RATING RATING RATING RATING 1st HOUR CONTINUOUS 1st HOUR CONTINUOUS 1st HOUR CONTINU...

Page 18: ...18...

Page 19: ...st price for a second coil REPLACEMENT PARTS Part Part No Description List Price T P Relief Valve TP 3 150 psi 210deg F 4 probe ANSI AGA Cert 22 35 Thermostat L4080 Honeywell L4080B 59 63 Thermostat W...

Page 20: ...the Product shall be ten 10 years from the date of manufacture of the Product WARRANTY COVERAGE FOR COMMERCIAL USAGE The following limited warranty set forth in this section shall apply to only the or...

Page 21: ...NTY ACT THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABIL...

Page 22: ...22 NOTES...

Page 23: ...23 NOTES...

Page 24: ...ECR International Inc 2201 Dwyer Avenue Utica NY 13504 4729 web site www ecrinternational com H2 O...

Reviews: