background image

 

8

 

4.  Operation  

                                                      

 

 

Preparation and Connections

 

 

            

 

 

Connect 

power cord to socket on ActivO’s rear panel (bottom) and only 

then connect it to the power source socket. 

 

     

6.1

 

Controller settings

 

 

 

 

 

OZONE IS A POWERFUL OXIDIZER.  USE THIS EQUIPMENT  WITH CARE  

AND IN UNINHABITED AREAS ONLY. READ ALL OPERATING  

INSTRUCTIONS BEFORE USING THIS MACHINE. 

 

RE-OCCUPY  TREATED  ROOM  ONLY  AFTER  PRESET  OPERATING  TIME  HAS 

ELAPSED  AND  THE  AMBER  FLASHING  LIGHT  HAS  STOPPED  FLASHING 

INDICATING THAT THE MACHINE IS NO LONGER IN OPERATION. 

 

DO NOT ATTEMPT TO ENTER THE ROOM WHILE MACHINE  

IS IN OPERATION; VENTILATE ROOM AFTER USE 

 

      

 CAUTION 

Summary of Contents for ActivO POCS-500

Page 1: ...ActivO ActivO ActivO ActivOTM User Manual for Europe 2008 Activated by ...

Page 2: ...l Specifications 6 Operation 8 Controller settings 8 Activation Deactivation and Total Operating Time 13 Maintenance and Service 14 Troubleshooting 15 Warranty 16 UNPACKING Open top flaps of carton Gently place carton on its side Lift unit up slightly and then pull out by rolling on its wheels Place handle on top panel and fasten 3 hex screws on each side Handle Front Grill Panel ...

Page 3: ... with ozone generated from the air using Ecozone s multi patented technology at a particularly high rate in order to reach homogeneous conditions and a high concentration level within the shortest possible time In the second stage any after treatment residual ozone is decomposed into oxygen so as to leave the treated room well within the regulated levels 2 Declaration of Conformity Model No POCS 5...

Page 4: ...a ventilation inlet and a ventilation outlet DO NOT BLOCK inlet outlet or place foreign objects in their vicinity which may block air flow Place unit in the CENTER of the room DO NOT disconnect cable cord from mains socket before the operation of the system is completed This unit is supplied with a earthed cable Attempting to bypass the earth or to connect the unit to an un earthed socket is stric...

Page 5: ...5 ...

Page 6: ...ctivation Deactivation Cycles Cycle time Minimum 15 minutes Maximum 48 hours With special input code 72 hours ozone generation only Control Digital keyboard Display LCD 16 Digits Safety Circuit breaker overload switch 4A Amber Flashing Light Indicator ActivO in operation Red Fault Indicator Buzzer Alarm operation has begun operation has ended Differential Pressure Regulator air flow obstructed Doo...

Page 7: ...s Indoor use only Temperature 0 ºC to 35 ºC Humidity maximum relative humidity 95 ECOZONE Technologies has a policy of continuous product improvement and reserves the right to modify or change this specification at any time without notice ...

Page 8: ...UL OXIDIZER USE THIS EQUIPMENT WITH CARE AND IN UNINHABITED AREAS ONLY READ ALL OPERATING INSTRUCTIONS BEFORE USING THIS MACHINE RE OCCUPY TREATED ROOM ONLY AFTER PRESET OPERATING TIME HAS ELAPSED AND THE AMBER FLASHING LIGHT HAS STOPPED FLASHING INDICATING THAT THE MACHINE IS NO LONGER IN OPERATION DO NOT ATTEMPT TO ENTER THE ROOM WHILE MACHINE IS IN OPERATION VENTILATE ROOM AFTER USE CAUTION ...

Page 9: ...oose between the following 4 room sizes Small for room volumes below 30m3 Medium for room volumes between 30m3 and 60m3 Large for room volumes between 60m3 and 120m3 X Large for room volumes from 120m3 to 500m3 The display will now prompt Set Time Select the Short Intermediate Long time cycle by pressing the respective button on keypad O Note Select length of cycle to correspond with the odour lev...

Page 10: ...ssing the Up or Down blue arrow buttons to extend or to shorten the operation cycle time respectively Please refer to reference chart on page 13 Up to extend cycle time Down to shorten cycle time Note Time is indicated on LCD in hours and minutes h hours and m minutes For example 3 hours and 20 minutes would be indicated so 3 h 20 m ...

Page 11: ...boards rubber under the keys floor squeegees tubes for bicycles crepe soles for shoes rubber bands various gloves Latex smoked sheets underlay and more The common sense rule when in doubt about whether the item contains natural rubber remove the item before treating the space Or alternatively smear the item s surface with Vaseline or equivalent before exposing it to ozone Before starting operation...

Page 12: ...tach 4 diameter ducting to ActivO Outlet page 5 When using ActivO in this manner there will be no ozone deactivation However ozone in the crawl space will deactivate naturally typically in 3 6 hours The display will prompt you to Get Out of Room and the amber Hazard light will begin flashing You must leave the room immediately Windows and doors should be closed to prevent ozone leakage Outside the...

Page 13: ...ion Complete and the amber light should have stopped flashing After the operation has ended and before moving the machine elsewhere be sure to disconnect the power cord from the power socket STOP RESET O CAUTION In the event indications do not correspond to the above leave the room immediately and call for ECOZONE service If at any time you need to reset the keyboard settings press STOP button red...

Page 14: ...0 Medium 60m 3 6 22 30 34 24 60 268 90 360 Large 120m 3 20 38 60 126 52 180 1318 120 1440 X Large 120m 3 178 120 300 598 120 720 2698 180 2880 Keyboard Controlled Maximum Change From Default Time Up Up Down Short Inter Long Time minutes G D T G D T G D T Room Volume Small 30m 3 17 11 30 70 18 90 28 60 90 Medium 60m 3 21 22 45 154 24 180 88 90 180 Large 120m 3 50 38 90 666 52 720 598 120 720 X Larg...

Page 15: ...a special Ozone Filtering Unit This Unit assures that upon completing the odour treatment cycle there will be no residual ozone left inside the room The efficiency of this Unit will degrade in time and therefor it is mandatory to replace it after every 1 000 hours of operation If you have a good pair of hands and follow these instructions carefully this 3 step procedure should take you about 1 hou...

Page 16: ...n 6 screws in frame around dust filter 25 so you can slide filter out Do not remove the earth cable connected to the grill c Gently slide filter up and out of its frame see picture d Place the filter under warm tap water and wash out dust It is ok to use a mild liquid soap if needed to loosen the dust Rinse and dry ok to use hair dryer e Slide Dust Filter back into its frame and retighten loosened...

Page 17: ...screws exposed in white circles in picture below shown after removal of Singlets Handle unit carefully e Clean the units under warm tap water especially the gaps between the tubes You may use a soft brush to remove any accumulated dirt Use care not to wet the electrical connector f Dry the Singlet units with a soft towel Continued Next Page Note the tubes used in the ActivO are unlike tubes used i...

Page 18: ... Replace the front grill making sure the dust filter is on the inside of the unit Make sure the earth cable to the grill is completely inside the unit b Re screw the 6 screws around the frame of the panel Step 4 Replacing Ozone Filtering Unit 17 a Open all screws at 3 locations connecting the used Ozone Filtering Unit 17 b Remove the used Ozone Filtering Unit and replace it by the new Unit c Screw...

Page 19: ...er cord Wait for Ready prompt Press STOP button red on keypad Press hard RESET button yellow on keypad Red light fault indication is ON and the display indicates one of the following fault codes a AL Presso Stat b AL Micro Switch Make note of fault code indicated on the display Disconnect power cord CALL ECOZONE service Display shows Needs Service This notification will appear every 500 hours of u...

Page 20: ...st first return the ActivO to ECOZONE together with proof of purchase from an authorized dealer of ECOZONE a Dealer either directly or through the Dealer from whom Purchaser purchased the ActivO for examination by ECOZONE of entitlement under the terms of this warranty All shipping handling travel service call and or other incidental and or related charges are fully payable by Purchaser only and a...

Page 21: ... MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE Contact information Ecozone Technologies Ltd Hasharon Industrial Park P O B 5014 Kadima 60920 Israel Phone 972 98 91 24 41 Fax 972 98 91 24 45 info ecozone technologies com www ecozone technologies com ...

Reviews: