SPLIT-TYPE ROOM AIR CONDITIONER

EDCM

TEMPERATURE

Room Temperature

 Outdoor Temperature

MODE

COOLING

OPERATION

HEATING

OPERATION

DRYING 

OPERATION

17 ºC ~ 32º C

(62º F~ 90º F)

0º C~ 30º C

(32ºF ~ 86º F)

10º C~32º C

(50º F~ 90º F )

0º C ~ 50º C

(32º F ~ 122º F)

0 ºC ~ 50 ºC

(32º F ~ 122 ºF)

(-15 ºC ~ 50 ºC

5º F ~ 122º F:

for models with low 

temperature cooling 

system)

-15 ºC ~ 30 ºC

(5º F ~ 86ºF)

This function is only available under COOL (AUTO COOL, FORCED 

COOL) and DRY mode.

Before select the function, it is recommended to run the air 

conditioner under Cooling operation for about half an hour. 

Once the Self Clean function is activated, all TIMER setting will be 

cancelled.

During Self Clean operation, when press the SELF CLEAN button on 

the remote controller again will stop the operation and turn off the 

unit automatically.

CLEAN AIR function (on some models)

This air conditioner is equipped with ionizer or Plasma Dust 

Collector (Depending on specific configuration of the model). 

With the anions generated by Ionizer, the air circulation of 

the air conditioner fills the room with refreshing, natural and 

healthy air. The Plasma Dust Collector generates a high voltage 

ionization zone, through which the air is converted to plasma. 

Inside the air most of the dust, smoke, and pollen particles are 

captured by the electrostatic filter.

Anti-mildew function (Optional)

When turns off the unit on COOL, DRY, AUTO (Cool) mode, the 

air conditioner will continue operating for about 7-10 minutes 

(depending on models) at LOW fan speed. If turns off on HEAT 

mode, the unit will continue operating for about 30 seconds at 

LOW fan speed. This will help to dry up the condensed water 

inside the evaporator, and prevent the breeding of mildew.

Under Anti-mildew operation, do not restart the air conditioner 

until the unit is completely off.

Vertical swing function (Optional)

After the AC starts up, users can control the vertical louver 

swing by the remote controller.

This manual does not include Remote Controller Operations, see the <<Remote 

Controller Instruction>> packed with the unit for details.

Optimum performance will be achieved within these operating 

temperatures. If air conditioner is used outside of the above 

conditions, certain safety protection features

might come into operation and cause the unit to function 

abnormally.

If the air conditioner runs for a long time in cooling mode and the 

humidity is high(over 80%) , condensed water may drip out of the 

unit. Please sets the vertical air flow louver to its maximum angle 

(vertically to the floor), and set HIGH fan mode.

Suggestion: 

For the unit adopts an Electric Heater, when the 

outside ambient temperature is below 0OC(32OF), we strongly 

recommend you to keep the machine plugged in order to 

guarantee it running smoothly.

MANUAL OPERATION

OPERATING TEMPERATURE

Units are equipped with a switch to run emergency operation 

mode. It can be accessed by opening the front panel. This switch 

is used for manual operation in case the remote controller fails 

to work or maintenance necessary.

The unit must be turned off before operating the manual control 

button. If the unit is operational, continue pressing the manual 

control button until the unit is off.

1

2

1

2

3

Open and lift the front panel up to an angle until it remains fixed 

with a clicking sound. For some models, please use suspension bars 

to prop up the panel.

One press of the manual control switch will lead to the forced AUTO 

operation. If press the switch twice within five seconds, the unit will 

operate under forced COOL operation.

Close the panel firmly to its original position.

CAUTIONS

This switch is used for testing purposes only. You had better not 

choose it.

To restore the remote controller operation, use the remote 

controller directly.

AUTO/COOL

AUTO/COOL

OPERATING INSTRUCTIONS

NOTES

NOTE

NOTE

NOTE

Summary of Contents for EDCM series

Page 1: ...EDCM OWNER S MANUAL SPLIT TYPE ROOM AIR CONDITIONER Thank you for purchasing this ecox product Before using this machine please read this manual and retain it for future reference EDCM EACM EDCM ...

Page 2: ...ISPOSAL Do not dispose of this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities The municipality has established collection systems where electronic waste can be disposed of at least free of charge to the user When buying a...

Page 3: ...res Never pull the plug out by pulling on the cable Hold the plug firmly and pull it out of the plug socket otherwise there is a risk of damaging the cable Do not operate your air conditioner in a wet room such as a bathroom or laundry room Remove all dirt from the power plug and plug it firmly Soiled plugs can cause fire or an electric shock In the event of any abnormalities such as smell of burn...

Page 4: ... too long with the doors or windows open or if the humidity is very high If the air conditioner is to be used in conjunction with other heaters the air should be refreshed periodically otherwise there is a risk of lack of oxygen Always pull out the power plug if the unit is not going to be used for any lengthy period of time Collections of dust can cause fire Always switch off the air conditioner ...

Page 5: ...in the machine So we strongly suggest that the open angle of the horizontal louver should not be set too small in case the condensed water forms and drops from the horizontal louver SELF CLEAN function Optional Function used after the Shut Down of cooling operation to clean the Evaporator and keep it as fresh for the next operation The unit will operate as following sequence FAN ONLY mode at Low f...

Page 6: ...etely off Vertical swing function Optional After the AC starts up users can control the vertical louver swing by the remote controller This manual does not include Remote Controller Operations see the Remote Controller Instruction packed with the unit for details Optimum performance will be achieved within these operating temperatures If air conditioner is used outside of the above conditions cert...

Page 7: ...perate the air conditioner for long periods with the air flow direction set downward in cooling or dehumidifying mode Otherwise condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings When the air conditioner is started immediately after it was stopped the horizontal louver might not move for approximately 10 seconds Open angle of t...

Page 8: ... highest comfort level Do not adjust the unit to excessive temperature levels Close doors and windows on COOL or HEAT modes or performance may be reduced Use TIMER ON button on the remote controller to select a time you want to start your air conditioner Do not put any object near air inlet or air outlet as the efficiency of the air conditioner may be reduced and the air conditioner may stop runni...

Page 9: ...it in cool place For the models with plasma do not touch the plasma within 10 minutes after you open the panel Install the air freshening filter back into position Insert the upper portion of air filter back into the unit taking care that the left and right edges line up correctly and place filter into position Replacement of air filter and air freshening filter Remove the air filter Remove the ai...

Page 10: ...e plastic parts in the unit when the temperature is changing A noise may be heard due to louver restoring to its original position when power is turned on Dust is blown out from the indoor unit This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit A peculiar smell comes out from the indoor unit This is caused by the indoor unit giving...

Page 11: ...e unplugged Fuse may have blown Battery in remote controller may have been exhausted The time you have set with timer is incorrect Inappropriate temperature setting Air filter is blocked Doors or windows are open Air filter or outlet of indoor or outdoor unit has been blocked Compressor 3 minutes protection has been activated Wait for power to be restored Check that plug is securely in wall recept...

Page 12: ...EDCM AF_ECX_ING_EDCM_MU_141114 ...

Reviews: