5
ECOWATER
S Y S T E
M S
Planning Installation
FIGURE 1 -- TYPICAL INSTALLATION DRAWINGS
floor drain
floor drain
NOTE
: Faceplate and support
not shown for clarity of drawing.
Tie or wire valve drain hose in place,
to keep
over floor drain.
valve drain
valve drain hose
brine tank
overflow
hose
brine tank
overflow hose
TWO TANK,
MODEL
CABINET
MODEL
1--1/2”
airgap
120V, 60Hz
outlet
transformer
(supplied)
to timer
to timer
1--1/2”
airgap
INLET
INLET
OUTLET
OUTLET
3-- valve
bypass system
inlet
valve
outlet
valve
bypass
valve
HARD
WATER
HARD
WATER
CONDITIONED
WATER
bypass valve
#7214383
INLET -- OUTLET PLUMBING OPTIONS
S
ALWAYS INSTALL either an EcoWater Systems
bypass valve #7214383, or a 3 valve bypass sys-
tem. Bypass valves allow you to turn off water to
the softener for repairs if needed, but still have
water in house pipes.
OTHER REQUIREMENTS
S
A drain is needed for regeneration discharge wa-
ter. A floor drain is preferred, close to the EcoWa-
ter Systems conditioner. A laundry tub, stand-
pipe, etc., are other drain options.
FIGURE 2 -- DRAIN OPTIONS
STANDPIPE
1--1/2”
airgap
drain
hose
1--1/2”
airgap
drain
hose
LAUNDRY TUB
S
A 120V--60Hz, grounded, continuously ‘‘live’’,
electrical outlet is needed within 10’ of the Eco-
Water Systems conditioner.
NOTE
: Codes in the state of Massachusetts require installation by a licensed plumber. For installation, use
plumbing code 248--CMR of the Commonwealth of Massachusetts.