Exhaust Air Heat Pump with CMEV

I. SPECIFICATION

MODEL

WEIGHT (KG)

DIMENSIONS (MM

)

POWER SUPPLY

EV-H20/180

83

620×1524

220V-240V/ 50Hz

EV-H20/270

94

620×1943

220V-240V/ 50Hz

II. APPEARANCE

III. FEATURES

ECOVOLT H20 EXHAUST AIR HOT WATER:

01.  Quality built duplex stainless steel 

water cylinder with 50mm factory 

fitted  rigid  insulation.  Lowstand

-

ing losses for energy efficiency in 

the storage of hot water.

02.  Quality highl

y  efficiency  micro

 

-channel heat exchanger wrapped 

in close contact with the cylinder 

for thermal conductivity. 

  

03.  No contact between the refriger-

ant piping and the water for addi-

tional safety

G E N E R A L   I N F O R M AT I O N

DUPLEX SS TANK

180L & 270L

ErP A++

R290

REFRIGERANT

HIGHEST EFFICIENCY IN IT’S CLASS

COMPLIANT

04.  The maximum outlet water tem-

perature is 70⁰C using a combina

-

tion of the heat pump and auxil-

iary heating element. For efficient 

heating using the heat pump only 

it is recommended that the hot wa-

ter temperature limit is set for 52⁰C.

 

 

 

 

 

 

 

 

 

05.  The heat pump uses extracted 

stale air from wet rooms delivered 

by rigid or semi-rigid ducting and 

connected using different meth-

ods as below. The air intake duct-

ing should be kept to a maximum 

combined length of 20 meters. 

For high performance buildings it 

is recommended to install a sup-

ply duct connected to the outside 

with an inline damper connected 

to the damper signal cable. This 

method will take energy from the 

outside air as well as the internal 

wet rooms. 

06.  Automatic and program modes 

available. 

Summary of Contents for EV-H20/180

Page 1: ...st Air Heat Pump with CMEV www ecovolt ie H20 Installation Manual INSTALLATION OPERATION MANUAL EXHAUST AIR HEAT PUMP FOR HOT WATER WITH CONTINUOUS MECHANICAL EXTRACT VENTILATION MODELS EV H20 180 EV...

Page 2: ...ailure to do so may result in the product not working according to its design This product must only be installed by qualified personnel in the mechanical and electrical industry Exhaust Air Heat Pump...

Page 3: ...3 Do not operate this heat pump in a wet room such as a bathroom or unless it is housed in a separate cupboard within that room Refrigerant R290 Warning This appliance uses R290 propane refrigerant wh...

Page 4: ...UPLEX SS TANK 180L 270L ErP A R290 REFRIGERANT HIGHEST EFFICIENCY IN IT S CLASS COMPLIANT 04 The maximum outlet water tem perature is 70 C using a combina tion of the heat pump and auxil iary heating...

Page 5: ...t ex changer EEV Electronic expansion valve the opening is regulated according to the discharge air temperature of compressor Fan Centrifugal fan with three speeds Tank Duplex stainless steel Heat Exc...

Page 6: ...INLET OUTLET PIPE G 3 4 FEMALE G 3 4 FEMALE RATED WATER TANK PRESSURE 8 bar 8 bar OUTER CASING RAL 9016 RAL 9016 FAN CENTRIFUGAL 3 SPEED CENTRIFUGAL 3 SPEED VENTILATION VERTICAL DISCHARGE VERTICAL DIS...

Page 7: ...void condensation when operational 08 Please ensure there is access to the front panel for maintenance Please note the clearance areas required for maintenance 09 Always allow extra room for pipe conn...

Page 8: ...NSTALLATION OF HEAT PUMP 01 Always leave enough space for installation and maintenance The below illustrations are guidelines only 02 The air inlet ducting is vented from wetrooms like a kitchen bathr...

Page 9: ...ocess until the tank is full and water begins to flow out of the safety relief valve 06 The correct cold water intake pressure is between 1 5BAR and 6 5BAR If the pressure is less than 1 5BAR a pressu...

Page 10: ...D MCB RCBO The circuit must be connected to a reliable earth electrode connected to the consumer unit The testing of the circuit and final connections are the responsibility of the trained installer N...

Page 11: ...is full with water Never operate if the tank is empty Follow the guidelines below to check the tank is full Open the cold water isolation valve and hot water outlet valve Hot water outlet Turn on a ho...

Page 12: ...disconnected the icon disappears Mode icon Power ON OFF Mode select Query Set menu Number keyboard Input numbers by different number keys Timer When timer is activated the icon appears When timer is...

Page 13: ...ill be activated Under this mode heat pump and electric heating element work simultaneously Timer mode Please refer to 3 5 3 for details All above modes could be accessible under timer mode Heat pump...

Page 14: ...ot suggested Both heat pump and electric heater will be turned on simultaneously by setting F13 to 0 adjustment is not suggested The reheat temperature could be set under F13 fast heating function adj...

Page 15: ...phone to be connected with WIFI Select Auto Scan also touch Configuring Wi Fi to input the WiFi name and password Now the phone will search the available devices 04 Turn on the controller Touch the b...

Page 16: ...uery Touch the button Temperature show the instant temperatures detected by different sensors Water inlet temp tank means the current water temperature Water outlet temp tank will not show any informa...

Page 17: ...EFRIGERANT OVER FILLING 2 BLOCKAGE OR AIR MIXED IN THE REFRIGERANT 3 PRESSURE SWITCH FAILURE 4 FAN DOESN T WORK NORMALLY 4 GAS EXHAUST TEMP PROTECTION 1 SENSOR FAILURE OR SENSOR CONNECTION WIRE FAILUR...

Page 18: ...ure sensor failure coil temperature sensor failure gas return temperature sensor failure the electric heating element will be automatically activated on above conditions which is not restricted by the...

Page 19: ...using the local isolator Unscrew the fixing screws That will allow the top casing to be removed Unclip the control wire to the touchscreen control panel and remove from the casing Using a vacuum clean...

Page 20: ...PARK DUBLIN 11 IRELAND AF TER SALE S ER VICE SHOULD YOU REQUIRE SERVICE ASSISTANCE WITH THE ECOVOLT H20 PLEASE LOG INTO OUR WEB SITE TO LOG YOUR SERVICE REQUEST THE FOLLOWING URL WILL TAKE YOU TO THE...