Exhaust Air Heat Pump with CMEV

III. OPERATION INSTRUCTION

 

When the system is off, touch the button “ON/OFF”, the system will turn on. 

 

When the system is on, touch the button “ON/OFF”, the system will turn off.

 

When the screen is in sleep mode, simply touch it to wake it up for operation. 

 

No operation on the controller for 5 minutes, the screen will enter sleep mode. 

Only the current water temperature will be displayed. 

3.1 Turn ON/OFF 

 

Heating mode: Touch the button “MODE” to select different working modes. 

Also the working mode will be showed on the top right corner of screen.

 

Only heating mode is accessible by “MODE” button for H20. Please refer to below 

for accessing other working modes.

 

→ Eco mode: When the Water temperature is set ≤ 55

o

C, only heat pump works.

 

Hybrid mode: When 55

o

C water temperature setting≤max 70

o

C, heat pump heats the water to 55

o

C. 

and stop working, then the electric heating element continues heating the water to set temperature.

 

Bo

oster mode: Touch the button “SET”→touch the button “User Para”→Touch the button “F13”, then this

 

mode will be activated. Under this mode, heat pump and electric heating element work simultaneously.

 

Timer mode: Please refer to 3.5.3 for details. All above modes could be accessible under timer mode.

 

Heat pump failure mode: When heat pump system fails, electric heating element will work automatically.

 

Low ambient temperature mode: When the ambient temperature is less than 5

o

only electric heating element is allowed to work.

3.2 Select working mode

 

Touch the icon           

      on the home Page to enter water 

temperature setting → Touch the button “+”, “-” to adjust water

 

temperature setting → Touch the button “OK”

 

to confirm water temperature setting.

 

The max water temperature the heat pump can achieve is 55

o

C, 

It is recommended not to raise the temperature above this.

 

The max water temperature that electric heating element 

could achieve is 70

o

C.

 

Based on above, DO NOT set water temperature over 70

o

C.

3.3 Set water temperature

 

Touch the icon                               on the home page to enter real-clock  

setting → Input the real time→Press the button “Return” to confirm 

 

the time and return to home Page.

 

Touch the button “SET” on the home page to enter real-clock  

setting → Touch the button “Clock” to calibrate the real date and time.

3.4  Real-Clock Setting

THERE ARE TWO WAYS TO ACCESS REAL-CLOCK SETTING.

Summary of Contents for EV-H20/180

Page 1: ...st Air Heat Pump with CMEV www ecovolt ie H20 Installation Manual INSTALLATION OPERATION MANUAL EXHAUST AIR HEAT PUMP FOR HOT WATER WITH CONTINUOUS MECHANICAL EXTRACT VENTILATION MODELS EV H20 180 EV...

Page 2: ...ailure to do so may result in the product not working according to its design This product must only be installed by qualified personnel in the mechanical and electrical industry Exhaust Air Heat Pump...

Page 3: ...3 Do not operate this heat pump in a wet room such as a bathroom or unless it is housed in a separate cupboard within that room Refrigerant R290 Warning This appliance uses R290 propane refrigerant wh...

Page 4: ...UPLEX SS TANK 180L 270L ErP A R290 REFRIGERANT HIGHEST EFFICIENCY IN IT S CLASS COMPLIANT 04 The maximum outlet water tem perature is 70 C using a combina tion of the heat pump and auxil iary heating...

Page 5: ...t ex changer EEV Electronic expansion valve the opening is regulated according to the discharge air temperature of compressor Fan Centrifugal fan with three speeds Tank Duplex stainless steel Heat Exc...

Page 6: ...INLET OUTLET PIPE G 3 4 FEMALE G 3 4 FEMALE RATED WATER TANK PRESSURE 8 bar 8 bar OUTER CASING RAL 9016 RAL 9016 FAN CENTRIFUGAL 3 SPEED CENTRIFUGAL 3 SPEED VENTILATION VERTICAL DISCHARGE VERTICAL DIS...

Page 7: ...void condensation when operational 08 Please ensure there is access to the front panel for maintenance Please note the clearance areas required for maintenance 09 Always allow extra room for pipe conn...

Page 8: ...NSTALLATION OF HEAT PUMP 01 Always leave enough space for installation and maintenance The below illustrations are guidelines only 02 The air inlet ducting is vented from wetrooms like a kitchen bathr...

Page 9: ...ocess until the tank is full and water begins to flow out of the safety relief valve 06 The correct cold water intake pressure is between 1 5BAR and 6 5BAR If the pressure is less than 1 5BAR a pressu...

Page 10: ...D MCB RCBO The circuit must be connected to a reliable earth electrode connected to the consumer unit The testing of the circuit and final connections are the responsibility of the trained installer N...

Page 11: ...is full with water Never operate if the tank is empty Follow the guidelines below to check the tank is full Open the cold water isolation valve and hot water outlet valve Hot water outlet Turn on a ho...

Page 12: ...disconnected the icon disappears Mode icon Power ON OFF Mode select Query Set menu Number keyboard Input numbers by different number keys Timer When timer is activated the icon appears When timer is...

Page 13: ...ill be activated Under this mode heat pump and electric heating element work simultaneously Timer mode Please refer to 3 5 3 for details All above modes could be accessible under timer mode Heat pump...

Page 14: ...ot suggested Both heat pump and electric heater will be turned on simultaneously by setting F13 to 0 adjustment is not suggested The reheat temperature could be set under F13 fast heating function adj...

Page 15: ...phone to be connected with WIFI Select Auto Scan also touch Configuring Wi Fi to input the WiFi name and password Now the phone will search the available devices 04 Turn on the controller Touch the b...

Page 16: ...uery Touch the button Temperature show the instant temperatures detected by different sensors Water inlet temp tank means the current water temperature Water outlet temp tank will not show any informa...

Page 17: ...EFRIGERANT OVER FILLING 2 BLOCKAGE OR AIR MIXED IN THE REFRIGERANT 3 PRESSURE SWITCH FAILURE 4 FAN DOESN T WORK NORMALLY 4 GAS EXHAUST TEMP PROTECTION 1 SENSOR FAILURE OR SENSOR CONNECTION WIRE FAILUR...

Page 18: ...ure sensor failure coil temperature sensor failure gas return temperature sensor failure the electric heating element will be automatically activated on above conditions which is not restricted by the...

Page 19: ...using the local isolator Unscrew the fixing screws That will allow the top casing to be removed Unclip the control wire to the touchscreen control panel and remove from the casing Using a vacuum clean...

Page 20: ...PARK DUBLIN 11 IRELAND AF TER SALE S ER VICE SHOULD YOU REQUIRE SERVICE ASSISTANCE WITH THE ECOVOLT H20 PLEASE LOG INTO OUR WEB SITE TO LOG YOUR SERVICE REQUEST THE FOLLOWING URL WILL TAKE YOU TO THE...

Reviews: