Exhaust Air Heat Pump with CMEV

Notes on the use of the product

01.  Household electrics must have a reliable earth 

 

connection.

02.  This product must be protected with a residual 

 

current device of adequate rating. 

03.  Do not interfere with any permanent instruction, 

labels or warning plate attached to the external 

cover of a this heat pump.

04. This  product must only be installed by 

qualified 

personnel 

in 

the 

mechanical

 

and electrical industry.  

05.  Always comply with local wiring regulations. 
06.  Always engage with a trained professional 

to relocate this product after it has been 

professionally installed. 

07.  Maintenance and repair work must only 

be 

undertaken 

by 

trained 

and 

qualified

 

personnel. 

08. The electrical connection to this product must 

be via a 20A RCD/MCB or RCBO with a test 

button function.  

09.  The

  final  electrical  connection  must  be  via

 

a double pole isolating switch located close 

to the unit. The isolating switch must never 

be covered up. 

10.  A One way isolating valve must be installed 

on the cold water supply pipe for maintenance 

 

purposes.  

11.  This appliance should never be used by children. 
12.  If the power supply cord is damaged, it must be 

replaced by the manufacturer, its service agent 

or  similarly  qualified  personnel  in  order  to  avoid  a 

 

hazard.

13. 

Do not operate this heat pump in a wet room 

such as a bathroom or unless it is housed 

in a separate cupboard within that room.

Refrigerant R290 Warning

 

This appliance uses R290 (propane) refrigerant, which 

is a flammable gas and must be serviced by an autho

-

rized person.

 

WARNING

 

Risk 

of 

fire/flammable 

material. 

 

If the refrigerant is leaking, switch off the unit at the 

mains and contact the service agent. 

 

DO not 

store chemicals or flammable materials near 

this appliance.

 

NEVER 

use  a  flammable  spray  such  as  hair  spray, 

paint, etc near this unit as this may cause a fire.

 

Avoid 

risk of injury from contact with 

 

refrigerant if you notice a leak.

 

If you suspect the refrigerant is leaking then:

 

Do not smoke.

 

Do  not operate electrical equipment. Isolate 

the device. Call the service agent. 

 

End of life recycling. Please consult your local recy-

cling centre for advice. 

The refrigerant must not enter the atmosphere.  

Only  have  the  refrigerant  removed  by  qualified 

 

professional. 

The H20 is designed for internal installation only. 

Where a system has been installed internally or in an 

unventilated room, the following parameters must be 

observed so that should any refrigerant leak, it will 

not stagnate so as to create a fire or explosion hazard. 

MINIMUM FLOOR AREA = 45m3, based off a charge 

of 0.350Kg and allowable practical limit for R290 

of 008Kg/M3 . 

This unit is required

reliable earthing before 

usage, otherwise might 

cause death or injury.

WARNING

RISK OF FIRE

S A F E T Y   P R E C A U T I O N S

Summary of Contents for EV-H20/180

Page 1: ...st Air Heat Pump with CMEV www ecovolt ie H20 Installation Manual INSTALLATION OPERATION MANUAL EXHAUST AIR HEAT PUMP FOR HOT WATER WITH CONTINUOUS MECHANICAL EXTRACT VENTILATION MODELS EV H20 180 EV...

Page 2: ...ailure to do so may result in the product not working according to its design This product must only be installed by qualified personnel in the mechanical and electrical industry Exhaust Air Heat Pump...

Page 3: ...3 Do not operate this heat pump in a wet room such as a bathroom or unless it is housed in a separate cupboard within that room Refrigerant R290 Warning This appliance uses R290 propane refrigerant wh...

Page 4: ...UPLEX SS TANK 180L 270L ErP A R290 REFRIGERANT HIGHEST EFFICIENCY IN IT S CLASS COMPLIANT 04 The maximum outlet water tem perature is 70 C using a combina tion of the heat pump and auxil iary heating...

Page 5: ...t ex changer EEV Electronic expansion valve the opening is regulated according to the discharge air temperature of compressor Fan Centrifugal fan with three speeds Tank Duplex stainless steel Heat Exc...

Page 6: ...INLET OUTLET PIPE G 3 4 FEMALE G 3 4 FEMALE RATED WATER TANK PRESSURE 8 bar 8 bar OUTER CASING RAL 9016 RAL 9016 FAN CENTRIFUGAL 3 SPEED CENTRIFUGAL 3 SPEED VENTILATION VERTICAL DISCHARGE VERTICAL DIS...

Page 7: ...void condensation when operational 08 Please ensure there is access to the front panel for maintenance Please note the clearance areas required for maintenance 09 Always allow extra room for pipe conn...

Page 8: ...NSTALLATION OF HEAT PUMP 01 Always leave enough space for installation and maintenance The below illustrations are guidelines only 02 The air inlet ducting is vented from wetrooms like a kitchen bathr...

Page 9: ...ocess until the tank is full and water begins to flow out of the safety relief valve 06 The correct cold water intake pressure is between 1 5BAR and 6 5BAR If the pressure is less than 1 5BAR a pressu...

Page 10: ...D MCB RCBO The circuit must be connected to a reliable earth electrode connected to the consumer unit The testing of the circuit and final connections are the responsibility of the trained installer N...

Page 11: ...is full with water Never operate if the tank is empty Follow the guidelines below to check the tank is full Open the cold water isolation valve and hot water outlet valve Hot water outlet Turn on a ho...

Page 12: ...disconnected the icon disappears Mode icon Power ON OFF Mode select Query Set menu Number keyboard Input numbers by different number keys Timer When timer is activated the icon appears When timer is...

Page 13: ...ill be activated Under this mode heat pump and electric heating element work simultaneously Timer mode Please refer to 3 5 3 for details All above modes could be accessible under timer mode Heat pump...

Page 14: ...ot suggested Both heat pump and electric heater will be turned on simultaneously by setting F13 to 0 adjustment is not suggested The reheat temperature could be set under F13 fast heating function adj...

Page 15: ...phone to be connected with WIFI Select Auto Scan also touch Configuring Wi Fi to input the WiFi name and password Now the phone will search the available devices 04 Turn on the controller Touch the b...

Page 16: ...uery Touch the button Temperature show the instant temperatures detected by different sensors Water inlet temp tank means the current water temperature Water outlet temp tank will not show any informa...

Page 17: ...EFRIGERANT OVER FILLING 2 BLOCKAGE OR AIR MIXED IN THE REFRIGERANT 3 PRESSURE SWITCH FAILURE 4 FAN DOESN T WORK NORMALLY 4 GAS EXHAUST TEMP PROTECTION 1 SENSOR FAILURE OR SENSOR CONNECTION WIRE FAILUR...

Page 18: ...ure sensor failure coil temperature sensor failure gas return temperature sensor failure the electric heating element will be automatically activated on above conditions which is not restricted by the...

Page 19: ...using the local isolator Unscrew the fixing screws That will allow the top casing to be removed Unclip the control wire to the touchscreen control panel and remove from the casing Using a vacuum clean...

Page 20: ...PARK DUBLIN 11 IRELAND AF TER SALE S ER VICE SHOULD YOU REQUIRE SERVICE ASSISTANCE WITH THE ECOVOLT H20 PLEASE LOG INTO OUR WEB SITE TO LOG YOUR SERVICE REQUEST THE FOLLOWING URL WILL TAKE YOU TO THE...

Reviews: