Exhaust Air Heat Pump with CMEV
Notes on the use of the product
01. Household electrics must have a reliable earth
connection.
02. This product must be protected with a residual
current device of adequate rating.
03. Do not interfere with any permanent instruction,
labels or warning plate attached to the external
cover of a this heat pump.
04. This product must only be installed by
qualified
personnel
in
the
mechanical
and electrical industry.
05. Always comply with local wiring regulations.
06. Always engage with a trained professional
to relocate this product after it has been
professionally installed.
07. Maintenance and repair work must only
be
undertaken
by
trained
and
qualified
personnel.
08. The electrical connection to this product must
be via a 20A RCD/MCB or RCBO with a test
button function.
09. The
final electrical connection must be via
a double pole isolating switch located close
to the unit. The isolating switch must never
be covered up.
10. A One way isolating valve must be installed
on the cold water supply pipe for maintenance
purposes.
11. This appliance should never be used by children.
12. If the power supply cord is damaged, it must be
replaced by the manufacturer, its service agent
or similarly qualified personnel in order to avoid a
hazard.
13.
Do not operate this heat pump in a wet room
such as a bathroom or unless it is housed
in a separate cupboard within that room.
Refrigerant R290 Warning
→
This appliance uses R290 (propane) refrigerant, which
is a flammable gas and must be serviced by an autho
-
rized person.
→
WARNING
Risk
of
fire/flammable
material.
If the refrigerant is leaking, switch off the unit at the
mains and contact the service agent.
→
DO not
store chemicals or flammable materials near
this appliance.
→
NEVER
use a flammable spray such as hair spray,
paint, etc near this unit as this may cause a fire.
→
Avoid
risk of injury from contact with
refrigerant if you notice a leak.
→
If you suspect the refrigerant is leaking then:
→
Do not smoke.
→
Do not operate electrical equipment. Isolate
the device. Call the service agent.
→
End of life recycling. Please consult your local recy-
cling centre for advice.
The refrigerant must not enter the atmosphere.
Only have the refrigerant removed by qualified
professional.
The H20 is designed for internal installation only.
Where a system has been installed internally or in an
unventilated room, the following parameters must be
observed so that should any refrigerant leak, it will
not stagnate so as to create a fire or explosion hazard.
MINIMUM FLOOR AREA = 45m3, based off a charge
of 0.350Kg and allowable practical limit for R290
of 008Kg/M3 .
This unit is required
reliable earthing before
usage, otherwise might
cause death or injury.
WARNING
RISK OF FIRE