![ECOUS EP2200i Owner'S Manual Download Page 24](http://html1.mh-extra.com/html/ecous/ep2200i/ep2200i_owners-manual_2355651024.webp)
23
APPLICATION RANGE
When using the generator, please make sure total load is under the range of
generator rated output, or the generator may be damaged.
AC
Power factor
1
0.8-0.95
0.4-0.75
(Efficiency 0.85)
2200i
1800VA
1440VA
612VA
2500i/2500iC
2100VA
1680VA
714VA
NOTE:
The overload alarm indicator ① is on (red)
When total watts exceed the application range.
(See page 15 for more details.)
NOTICE:
Make sure the total load is in the range of generator rated output
otherwise generator damage will occur.
The simultaneous usage of AC and DC power is possible, but total watts
should not exceed the rated output, otherwise generator damage will
occur.