8
draw through the appliance to achieve good combustion. When this happens, the stove should not be
used.
IMPORTANT: -
As of October 2010, it is a legal requirement to use a Carbon Monoxide Detector in the same room as
the stove. This needs to incorporate a battery which lasts the life of the detector.
CLEANING/MAINTENANCE
When cold, the inside of the stove should be given a regular sweep out.
The flue and flue pipe will require cleaning with a suitable chimney brush, to minimise build-up of soot
and tar. Your chimney will also require periodic sweeping.
If the glass becomes stained from the inside, the air-wash vent may need opening more during use.The
high temperature paint which your stove is finished in should last many years with normal use, but
when it does eventually require re-finishing, black heat resistant paint in spray cans can be purchased
from most hardware stores. – Do not use regular paint which is not high temperature resistant. After
prolonged periods of not using the fire, the stove and flue system should be checked for blockages
prior to relighting. We recommend regular servicing and safety checks are carried out by a qualified
engineer. There must be no unauthorised modification of the appliance. Use only replacement parts
recommended by the
manufacturer.
MODELS WITH MIRROR GLASS: THIS GLASS HAS A SPECIAL COATING, DO NOT USE ANY ABRASIVE
MATERIAL TO CLEAN THE GLASS. Just use a clean cloth with warm water when the stove is cold, if you
clean the glass when it is still warm the glass can “craze”, crazing can also occur if incorrect fuels are
burnt on the stove. If fire bricks have just split, they do not need replacing. The bricks only need
replacing when they have fully crumbled away exposing the stoves rear or sides.
GUARANTEE
The main body of your stove is guaranteed for 5 years. This does not include glass, grates, door seals,
over-firing, and paint.
Incorrect use or installation not carried out by a registered HETAS installer will void the guarantee. The
only exceptions will be if the install has been signed off by the council. Please keep hold of the invoice
as this will be requested if a claim started, if this is not provided upon request we will not be able to
escalate your claim. The guarantee will begin from the sale date on the invoice and we do not cover
any cost incurred when removing faulty appliances or installing new ones, even if it has been proven
that the stove is faulty.
-
Ecosy+, Unit 24 – Folly farm, Ramsdell, Tadley, RG26 5GJ
Summary of Contents for Purefire Panoramic 5kw Slimline - SE
Page 9: ...9...
Page 10: ...10 Mechanical stop installed 18mm from the closed position for SE versions of this model...
Page 11: ...11...