7
First use troubleshooting.
When the stove is new the paint is very tacky where the stove is curing. The door locks very tight and
when opened can pull away the fire rope from its chamber. If the instructions are followed above this
should not happen. However, if it does the rope will need to be stuck back in place with “heat resistant
fire rope glue” After a few burns the paint will be cured and this should no longer happen.
Refuelling
Every stove will work slightly differently depending on the chimney, or flue system it is attached to. It can
take time to get use to the stove and how best to run and control it in each situation.
When refuelling it is necessary to set the air control fully open for a period of 1 to 3 minutes in order to
sustain flames on the new refuel charge –
nominal power output, your stove will require refuelling approximately every hour.
d to maximise the
efficiency of the stove
shed on the newly charged logs
-establish the fire and follow the
“Ignition” procedure above.
fuel.
vents.
– If there is insufficient burning material in the firebed to light a new
fuel charge, excessive smoke emission can occur.
Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel
charge will ignite in a reasonable period. If there are too few embers in the fire bed, add suitable
kindling to prevent excessive smoke.
Fuel overloading - The maximum amount of fuel specified in this manual should not be exceeded,
overloading can cause excess smoke.
Operation with door left open – Operation with the door open can cause excess smoke. The appliance
must not be operated with the door left open except as directed in the instructions.
WARNING- The high temperature paint covering the stove will give off some fumes during the initial
few uses of the stove. The fumes are non-toxic, but some people may find them unpleasant – Ensure
the area is well ventilated during this period.
This stove is suitable for intermittent burning, and should not be used constantly for extended periods.
Under certain abnormal weather conditions, e.g. down draughts, it may be difficult to get sufficient