background image

 

 

under Section 16 of the Environmental Better regulation Act (Northern Ireland) 2016.    In Wales 

appliances are exempted by regulations made by Welsh Ministers.   

 

Further information on the requirements of the Clean Air Act can be found here: 

https://www.gov.uk/smoke-control-area-rules

   

 

The Ecosy+ Purefire Panoramic 5kW Slimline - SE has been recommended as suitable for use in smoke 

control areas when burning seasoned wood logs. The appliance has a factory-fitted modification to the 

secondary air control to prevent closure beyond 18mm open.   

 

Your local authority is responsible for implementing the Clean Air Act 1993 including designation and 

supervision of smoke control areas and you can contact them for details of Clean Air Act requirements. 

 

Please note the following advice on minimising smoke emissions : 

 

Refuelling on to a low fire bed 

If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke 

emission can occur. Refuelling must be carried out onto a sufficient quantity of glowing embers and 

ash that the new fuel charge will ignite in a reasonable period. If there are too few embers in the fire 

bed, add suitable kindling to prevent excessive smoke. 

 

Fuel overloading 

The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause 

excess smoke. 

 

Operation with door left open 

Operation with the door open can cause excess smoke. The appliance must not be operated with the 

appliance door left open except as directed in the instructions. 

 

Dampers left open 

Operation with the air controls or appliance dampers open can cause excess smoke. The appliance 

must not be operated with air controls, appliance dampers or door left open except as directed in the 

instructions. 

 

 

FUEL 

Wood- All types of wood are suitable provided they are well seasoned, UNTREATED, and have a 

moisture level between 12% and 20%. For soft woods, typically they will need to have been left in 

suitable storage for 9+ months for the moisture to evaporate. For hardwoods, this will usually be 18 

.

 

It is recommended that logs should be no more than 5” or 125mm in diameter and 10” 25cm 

in length. If you are unsure of the moisture content of your fuel, then you can buy a moisture meter 

which will indicate the moisture levels in your fuel. Liquid fuels must NEVER be used. 

Summary of Contents for Purefire Panoramic 5kw Slimline - SE

Page 1: ...noramic 5kw Slimline Standard and SE versions Installation and Operating Instructions Version 1 1 20 10 2017 Wood burning Stove Model Ecosy Purefire Panoramic 5kw Slimline SE Dimensions 560mm wide 314...

Page 2: ...s not require an ash pan or multi fuel grate INSTALLATION Installation of your stove must comply with relevant local and national Building Regulations and fire safety standards We would always suggest...

Page 3: ...at the passageways for exhaust gases remain free from obstruction OPERATING INSTRUCTIONS Regulations All National and local regulations including those referring to national and European standards nee...

Page 4: ...fuel charge will ignite in a reasonable period If there are too few embers in the fire bed add suitable kindling to prevent excessive smoke Fuel overloading The maximum amount of fuel specified in thi...

Page 5: ...ed over the fire re burning the initial smoke produced from the stove The air is also warmed and fed over the glass helping to keep it clean When pushed to the left this is restricted SE DEFRA version...

Page 6: ...d in temperature and log size and load A stove thermometer will be a valuable tool in helping you to achieve this safely and also to ensure an efficient burn rate in future Starting a large fire too s...

Page 7: ...nd follow the Ignition procedure above fuel vents If there is insufficient burning material in the firebed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out...

Page 8: ...by a qualified engineer There must be no unauthorised modification of the appliance Use only replacement parts recommended by the manufacturer MODELS WITH MIRROR GLASS THIS GLASS HAS A SPECIAL COATIN...

Page 9: ...9...

Page 10: ...10 Mechanical stop installed 18mm from the closed position for SE versions of this model...

Page 11: ...11...

Page 12: ......

Reviews: