WARNING: Wet timber should not be used as this will create excess tar deposits in the chimney and
stove and could increase the risk of chimney fire. Timber which is not of a suitable moisture content
will also create more smoke and harmful emissions, and will damage the stove and flue system.
AIR INLET CONTROLS
Base leaver - This controls the Secondary/Airwash and Tertiaryburn system. When pushed to the right
this feeds more air through the stoves rear. The air is fed over the fire re burning the initial smoke
produced from the stove. The air is also warmed and fed over the glass helping to keep it clean. When
pushed to the left this is restricted.
SE/DEFRA version
On the smoke exempt appliance this air vent is set such that the closure plate does not seal fully, thus
allowing some constant air supply into the stove.
TOOLS
The glove is provided for adjusting the air inlets and for opening the door when the stove is hot, as
these knobs will heat up when in use. The tool handle provided is for removing the ash-pan.
NOTE – all parts of the stove will become hot during use and care needs to be taken to avoid injury