34
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2016
INSTALLER AND USER GUIDE FOR REVERSE OSMOSIS SYSTEM ECOSOFT ROBUST 1000, ROBUST 3000
1) Filter rack with booster
pump
2) Pre-filters and post-filter
3) Reverse osmosis
membranes
2.3 SYSTEM COMPONENTS
2.2 FEED WATER REQUIREMENTS
Parameter
Value
1
pH
6.5…8.5
TDS, mg/L (ppm)
<1500
Total hardness, °dH
ppm CaCO
3
<30
<500
Active chlorine, mg/L (ppm)
<0.5
Total iron, mg/L (ppm)
<0.3
Total manganese, mg/L (ppm)
<0.1
COD, mg O
2
/L (ppm O
2
)
<5
Total microbial count (TMC), CFU per 1 mL
<100
E. coli, CFU per 100 mL
None
1
If feed water quality does not meet specified requirements, membrane and filter service life may decrease. If
aiming to purify raw water (well water/ground water etc.), it is recommended to carry out detailed water anal-
ysis. If any constituents exceed the above limitations, it is advisable to install a special filter upstream of your
reverse osmosis system. Consult professional water treatment specialist for proper selection of an appropriate
filter for your water.