10. HEALTH AND ENVIRONMENT SAFETY INFORMATION

11. PURCHASING

12. TRANSPORTATION AND STORAGE

  13. WARRANTY

This product does not produce any chemical, electrochemical, or radiological impact on the envi-

ronment. The product is not recognized to have any hazardous impact on human body, and meets 

requirements of relevant sanitary legislation for its intended scope of use.

Ideally,  the  product  should  be  purchased  from  authorized  dealer.  Before  making  the  purchase, 

check integrity of packaging, absence of mechanical damage and other defects, completeness of 

the system (without opening the plastic bags), availability of user documentation, particularly this 

manual and warranty card.

The product can be shipped by any means of transport (except unheated during cold seasons in 

colder climates) in accordance with the rules of goods transportation applicable to each type of 

transport. Observe handling labels when handling and shipping the product. The product should be 

stored indoors protected from mechanical damage, moisture, and aggressive chemicals, in vendor’s 

original packaging, at an ambient temperature in the range of 5…40 °C (41...104 °F) and relative 

humidity up to 80%, not closer than 1 m (3.3 ft) to any heating appliances.

Thank you for purchasing Ecosoft reverse osmosis system! We hope that this product will serve you 

long and let you and your family enjoy high quality pure drinking water.
The product vendor guarantees that the system has no manufacturing defects, and no defects will 

arise within warranty period from the date of purchase provided that the technical requirements 

and operating conditions specified in this manual are strictly adhered to.
Please carefully read this Instruction manual, warranty liabilities, check that warranty card is filled 

and complete with a proof of purchase (cash receipt, invoice, or installer’s receipt). Warranty card 

will not be valid if the product model, date of purchase, and dealer’s stamp are not present and 

clear. Carefully read the installation and operation parts of the manual before installing or use ser-

vices of a qualified professional.
The vendor shall not be held liable for any property damage or other loss, including lost profits, 

accidental or due to use or inability to use this product. Liability of the vendor shall not exceed 

value of the product.

Summary of Contents for ROBUST 1000

Page 1: ...ECOSOFT ROBUST 1000 ROBUST 3000 FOR REVERSE OSMOSIS SYSTEMS ECOSOFT ROBUST 1000 ROBUST 3000 INSTALLER AND USER GUIDE...

Page 2: ...del 36 3 2 ECOSOFT RObust with pressure tank 37 3 3 ECOSOFT RObust with pressure tank and ultraviolet lamp 37 4 Installation steps 38 4 1 Installation conditions and package completeness check 38 4 2...

Page 3: ...etrate through cellular membrane Ecosoft RObust is a high recovery direct flow operation capable reverse osmosis system The system can be equipped with a pressure tank for increasing purified water fl...

Page 4: ...r line or pressure tank if installed passing through the carbon post filter Purified water line may go to purified water faucet or be connected with some other consumer appliance High pressure switch...

Page 5: ...auge no 2 shows pressure between two membranes Permeate goes to the purified water line or pressure tank if installed passing through the carbon post filter Purified water line may go to the purified...

Page 6: ...fied water Using the system with feed water above 30 86 F is advised against 2 SPECIFICATIONS AND COMPONENTS 2 1 TECHNICAL SPECIFICATIONS Parameter Value RObust 1000 RObust 3000 Purified water flow ra...

Page 7: ...m 0 5 Total iron mg L ppm 0 3 Total manganese mg L ppm 0 1 COD mg O2 L ppm O2 5 Total microbial count TMC CFU per 1 mL 100 E coli CFU per 100 mL None 1 If feed water quality does not meet specified re...

Page 8: ...is prohibited 2016 INSTALLER AND USER GUIDE FOR REVERSE OSMOSIS SYSTEM ECOSOFT ROBUST 1000 ROBUST 3000 4 Feed adapter 6 Purified water faucet 7 Feed valve 1 Filter rack with booster pump 5 Drain saddl...

Page 9: ...o connection Inlet Run red tube from feed water outlet to the inlet port in port rack CAUTION The additional accessories should be used for the installation of RObust 3000 reverse osmosis system These...

Page 10: ...included in the system components Purified water Run blue tube from purified water port to purified water faucet Drain Run black tube from drain port to drain saddle installed on drain pipe Pressure t...

Page 11: ...alist company for assistance selecting the appropriate product for normalizing the offending constituents 3 Before proceeding with the installation ensure there is enough space for the assembled syste...

Page 12: ...eed valve tube connection Slip red tube through the nut and connect it to the feed valve tube connection then screw compression nut back on till snug Connect the other end of the red tube to the inlet...

Page 13: ...ath sink surface 7 3 Put compression nut on the free end of the blue tube then put on the ferrule and the insert inside the tube 7 4 Push the end of the blue tube inside the shank bottom a few centime...

Page 14: ...s to rinse membranes and other parts of the system Do not open tank valve at this time Close the purified water faucet and check all connections for leaks CAUTION Inspect the system for leaks every da...

Page 15: ...that pre filter is clogged and need to be replaced as soon as possible Delayed replacement of pre filters can result in damage or failure of the membranes In order to avoid this it is recommended to r...

Page 16: ...aler s service If pressure on the 2nd pressure gauge is over 7 bar 101 5 psi this could be due to pressure regulator failure or the RO system s high pressure switch fault Contact your dealer s service...

Page 17: ...water becomes free of carbon particles close feed water valve Plug the tubes back in the inlets in membrane housings Secure connections with locking clips 8 Open feed valve and plug the system in the...

Page 18: ...ble cause Method of handling Fitting leak Tube is not connected tightly Remove and reinstall the tube properly Filter housing leak O ring seal is missing or mis aligned Check that the O ring seal is c...

Page 19: ...ace membranes The system has switched off but continues to send water to drain Solenoid valve failure Replace the solenoid valve Protect the system from de bris and particulates if present in feed wat...

Page 20: ...Contamination of pressure tank Sanitize pressure tank Pressure tank may become contaminated if filters or membranes are used beyond their service life Pressure tank is not full when the system switche...

Page 21: ..._________________________________________________________Signature___________ Date__________ Installer____________________________________________________________________ Signature___________ Date____...

Page 22: ...e No claims were made as attested to by signa tures below ROBUST RO SYSTEM MAINTENANCE REPORT FORM Step Result Remarks Date of service Specification of service Used consumables product name lot date o...

Page 23: ...ored indoors protected from mechanical damage moisture and aggressive chemicals in vendor s original packaging at an ambient temperature in the range of 5 40 C 41 104 F and relative humidity up to 80...

Page 24: ...this manual and use of consumables from other vendors Claims of water quality issues including taste odor and other properties will only be accepted with water test report issued by an accredited lab...

Page 25: ......

Reviews: