8.
TROUBLESHOOTING
Drinking water has a milky or
cloudy appearance that goes
away after a few minutes
Air in the system
Some air in the system is normal for a few days
after the system was installed.
In some cases, air bubbles may appear due to
supply water being significantly lower temperature
than your home’s ambient temperature
Water has a taste and/or odor
Carbon post-filter has expired
Replace the post-filter
Preservative solution in the
membrane has not been flushed
out
Drain all the water from the tank and let the
system re-fill it
Contamination in reverse osmosis
system
Sanitize the system per instructions in section 7
Contamination in pressure tank
Replace the tank or sanitize per instructions in
paragraph 7.1
Pressure tank holds too little
water
Tank bladder is overpressurized
Pressure in empty tank should be 0,4-0,6 bar (6-9
psi). Make sure pressure in your tank is in line with
the above figures
No water is dispensed from
faucet albeit tank is full
Tank bladder is underpressurized
Pressure in empty tank should be 0,4-0,6 bar (6-9
psi). Make sure pressure in your tank is in line with
the above figures
Tank valve is closed
Open tank valve
Summary of Contents for RO 5-100