32
33
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2014
ENG
REVERSE OSMOSIS SYSTEM INSTALLER AND USER GUIDE
6.
Disconnect the tube going to the storage tank from the union tee
before the carbon post-filter, and into 3
rd
pre-filter’s outlet.
7.
Put a disinfection tablet in the 1
st
sump. Fill the sump with water and screw on.
8.
After 15 minutes, open tank valve
6
.
9.
Open the feed valve
5
for 5 minutes.
10.
Close the tank valve
6
and leave the tank filled with chlorine solution for 1-2 hours.
11.
Open tank valve
6
and drain all water from the tank to the sink. Disconnect it from the third pre-filter and restore the
original tubing of the system.
12.
Put cartridges in sumps and install the sumps on their heads. Then, open tank valve 6 and feed valve
6
.
13.
Drain the tank and re-fill for at least three times (until chlorine odor cannot be smelt).
7.
SANITIZATION OF REVERSE OSMOSIS FILTER
Summary of Contents for RO 5-100