How to choose a ventilation or a filtration box ?  

 

Ventilation boxes

 are connected to the safety cabinet with a connecting kit (including a connecting sleeve, 2 hose clamps and 1 meter 

of  flexible  sheath)  ;  the  fan  included  in  the  box  extracts  the  toxic  vapors  contained  in  the  cabinet,  and  reject  it  to  the  outside  of  the 

building thanks to the roof or wall extraction.   

 

If you cannot reject the vapors to the outside, you need a filtration box.  

 

Filtration boxes

 are equipped with an activated carbon filter, which purifies the toxic vapors in the box, and rejects it in the room in a 

healthy fashion. Filtration boxes are delivered with the activated carbon filter that you need to renew once a year.  

 

Running without any mechanic ventilation 

It  is  possible  for  your  safety  cabinet  to  run  without  mechanical  ventilation.  However,  your  cabinet  has  to  be  placed  in  a  location  that 

provides its own ventilation system (at least 5 times the volume of the location, per hour).  

The cabinet itself and a radius of 2,5 meters directly around is a dangerous area subject to explosions.  

 

On the other hand, if the ventilation system of your cabinet is not running, you have to indicate it, by putting an etiquette on the cabinet, 

saying “Safety cabinet not connected to the mechanic ventilation” (etiquette is not provided). 

 

 

7.  SAFETY CONTROLS 

 

Your safety cabinet is a safety equipment. As to guarantee its perfect efficiency, you have to check the equipment regularly.  

 

Summary of Contents for MC90

Page 1: ...Range 2 MC90 Operating instructions ECOSAFE Date du document 29 04 2019 Version 01 0 Instruction manual For safety cabinet Model MC90 ...

Page 2: ...ONTENT 1 Description Use Page 2 2 Technical features Page 2 3 Installation and commissioning Page 2 4 Internal equipments Page 3 5 Storage Page 3 6 Ventilation Page 3 7 Safety controls Page 4 8 Spare parts Page 5 9 Recycling Page 5 10 Warranty Page 5 11 Control sheet for the user Page 7 ...

Page 3: ...ters for versatile storage Leakproof 2 51 mm bottom sump Dual vents with flame arresters 4 self leveling feet Grounding connector External dimensions H 1650 x W 1100 x D 860 mm Internal dimensions H 1560 x W 1020 x D 780 mm Storage capacity 340 liters Retention capacity 40 liters Loading capacity 159 KG per shelf Weight 220 KG 3 INSTALLATION AND COMMISSIONING Installation The safety cabinet has to...

Page 4: ...se The doors open by pulling the handle towards you 4 INTERNAL EQUIPMENTS The cabinet is provided with 2 shelves This must be fixed at the chosen height thanks to the rack and pinion Take care not to exceed the loading capacity per shelf of 159 KG The cabinet also has an integrated retention tank which has a retention capacity of 40 liters 5 STORAGE Your safety cabinet is exclusively destined to s...

Page 5: ... a healthy fashion Filtration boxes are delivered with the activated carbon filter that you need to renew once a year Running without any mechanic ventilation It is possible for your safety cabinet to run without mechanical ventilation However your cabinet has to be placed in a location that provides its own ventilation system at least 5 times the volume of the location per hour The cabinet itself...

Page 6: ...arious elements such as the steel can be recycled Ensure to respect the national and local waste disposal terms Those elements should not be mixed with household waste 10 WARRANTY Your equipment holds a 12 months warranty against every manufacturing defect limited to ordinary conditions of use from the date indicated on the delivery note Our warranty can be applied only in case of manufacturing de...

Page 7: ...mal attrition of the equipment In case of a bad installation of the equipment In case of damage caused by the corrosion The activation of the warranty won t extend the term Our warranty stops if the customer has not notified us in a 7 days term after seeing the fault date that the customer has to prove ...

Page 8: ...y The locking system of the doors works correctly The mechanic ventilation system is running correctly if applicable The ventilation system is not obstructed The air inlet and outlet are clean The standardized pictogram on the door is in good condition and visible The door hinges are lubricated The locking system is lubricated The containment sump is clean Remarks Date By Signature ...

Reviews: