9
ULTRAVIOLET (UV) LAMP AND SLEEVE ASSEMBLY
1
1. Locate canister number 4 (shown on previous page).
With the
plastic cover
removed, remove the threaded
retainer
on the top of the ultraviolet (UV) canister. (See
figure 1 & 2).
2
2. Open the carton containing the
UV lamp
and
the
quartz sleeve
. Remove the
quartz sleeve
from its packing. (Be sure not to remove UV bulb
from packing yet).
5
5. Place the threaded
retainer
over the top of the
sleeve
and gently tighten the cap until it is snug and the top of
the
sleeve
is properly seated in the cap. Do not over-
tighten as the
sleeve
may break (See figure 4).
6
6. Check the seat at the top of the
sleeve
by
reaching into the middle of the
retainer
and
rubbing a finger along the inside of the glass.
There should be a slight gap between the glass
and the
cap
. If an uneven gap is present, do
not attempt to tighten the
cap
further as the
sleeve
will break. The uneven gap indicates
that the
sleeve
is misaligned. STOP and repeat
step #3 taking care to insure proper seating and
alignment of the sleeve.
7
7. Remove the
UV lamp
from the packing and clean
thoroughly with rubbing alcohol to remove all traces
of oil and grease. Be careful not to touch the glass
lamp
area with your fingers as this will leave oils on
the
lamp
, causing the
lamp
to fail prematurely.
8
8. Carefully slide the
UV lamp
through the
retainer
and into the
quartz sleeve
making
sure that the lamp prongs are at the top
(See figure 5).
9
9. Plug the ballast into the top of the
UV lamp
(See figure 6).
10
10. Place the
plastic cover
over the
retainer
to
protect the top to the
UV lamp
. The
lamp
should
be seated low enough in the
sleeve
so that when
the
plastic cover
is in place, there is clearance
between it and the cabinet top (See figure 7).
Plug ballast into properly grounded 110-120 Volt
household receptacle.
3
3. The
quartz sleeve
resembles a large test tube.
Remove the sleeve from the packing and place it
into the top of the UV canister and carefully lower it
into place. Be sure the
sleeve
is straight and slides
fully into the receiving tube at the bottom of the
canister. The sleeve will be fitted with a black O-ring
and a plastic washer near the top. These should be
positioned about 1/2 inch from the top of the tube.
All water should be removed from the canister before
proceeding with this step (See figure 3).
4
4. Check that the bottom of the
sleeve
is seated
properly by gently depressing the top edge
of the sleeve with a finger. The sleeve should
bounce on the spring located in the receiving
tube. If it does not bounce the tube is misaligned
and must be re-seated BEFORE proceeding.
Apply a very thin coat of unscented petroleum
jelly to the top rim of the sleeve. Be careful not
to get any of the jelly on the inside of the sleeve.
figure 1
figure 2
figure 7
figure 6
figure 5
figure 4
figure 3
WARNING: THE SLEEVE IS FRAGILE. ROUGH HANDLING OR MISALIGNMENT WILL CAUSE IT TO BREAK.
CAUTION - SHOCK HAZARD: BE SURE UNIT IS PROPERLY GROUNDED (SEE PAGE 7) AND AREA
IS FREE OF STANDING WATER BEFORE PLUGGING UNIT INTO RECEPTACLE.
1/2”