8

ASSEMBLING YOUR SPRINGHOUSE FILTERS

WASH HANDS THOROUGHLY AND FREQUENTLY WHILE HANDLING FILTER 

CARTRIDGES TO AVOID CONTAMINATING THE CARTRIDGES.

WORK WITH ONLY ONE FILTER CANISTER AT A TIME TO AVOID 

MIXING UP THE FILTERS. DO NOT OVER TIGHTEN THE CANISTER. 

FILTER CANISTER INSTALLATION

3

 3.  Wash the inside of the canister using hot 

water and a small amount of household 
dish washing detergent (automatic dish 
washing detergent is best). 
Rinse the canister thoroughly using clean 
water until all soap residue is removed.  
Remove the protective plastic from the filter 
which should be marked with the number 1 
and place it in the housing.

1

1.   Remove the blue filter canisters  

(containing the filters) from the boxes.

4

4.  Apply a light coat of food-grade lubricant (such as silicone gel) to 

the surface of the black O-ring at the top of the housing. 

This step 

is very important and cannot be skipped for any reason.

2

2.   Each blue filter canister, black canister cap 

(on the unit) and filter is numbered. Take 
filter canister #1, remove the filter from the 
canister and set aside. 

CAUTION:

Do not over tighten  

canisters when installing.

5

5.  Being careful to match the number on the blue canister with the 

number on the black canister head, carefully screw the blue canister 
into the black portion of the filter canister. Hand tighten the canister. 
Snug with supplied wrench. DO NOT overtighten canisters. 

NOTE: FILTER PACKING MUST BE 

REMOVED BEFORE INSTALLATION.

6

6.  Repeat the installation process, in-turn, for canisters 2, 3, 5, and 7. 

Container 6 will contain the polyphosphate granules, see step 7.

 

NOTE: 

When a new Carbon or KDF filter is installed, it is strongly 

recommended that the 1-micron filter (canister #7) not be installed until 
the system is fully flushed as described in item 21 under "Replacing Filter 
Cartridges" (page 10). This will prevent premature clogging of the filter.

NOTE: Canister 4

is for the UV lamp.

(See next page)

£

Ó

Î

Ç

È

x

{

7

7.  For canister 6, clean as recommended for canisters 1, 2, 3, 5,  

and 7. Open the bag of polyphosphate granules and pour them  
into the canister. Install the canister.

Summary of Contents for SpringHouse

Page 1: ...Owner s Manual ...

Page 2: ...ringHouse is to be installed Otherwise you will not be able to install and or remove the UV lamp and the quartz sleeve NOTE Installation must be done by a qualified plumber in accordance with local codes Failure to do so can result in damage not covered by your SpringHouse warranty SpringHouse s unique design allows for easy maintenance and operation The System Bypass function allows your water so...

Page 3: ..._________________________________________________________________ SPRINGHOUSE SPECIFICATIONS Maximum Flow Rate 8 G P M 60 psi Dimensions 41 L x 16 W x 40 H Inlet Outlet Pipe 1 inch schedule 80 PVC Operating Temperature Range 35 to 100 degrees Fahrenheit Inlet Pressure Range 25 to 60 psi Operating Supply Pressure Range 25 to 250 psi Warranty 2 Years parts and labor Micron Rating 1 micron absolute A...

Page 4: ... Chamber Plug Cap located atop UV chamber by pulling upwards 4 Remove UV Chamber retainer fitting by turning counter clockwise 5 Locate the shipping tube containing the UV Lamp glass lamp sleeve spring nylon washer and rubber O ring Caution handle UV lamp and sleeve carefully to avoid breakage 6 Lubricate the top inch of the outside of the lamp sleeve with either vegetable oil or some type of inge...

Page 5: ...hamber Step 5 MAZ filter Step 6 Anti scalent sequestering agent polyphosphate Step 7 1 micron filter absolute particulate filter Specialty filters are available for treatment of unique contaminants These are normally installed in place of the sequestering agent in canister 6 Ask your Independent Business Owner for details Additional Information Filter life varies with all filters because of broad ...

Page 6: ... Failure to do so can result in damage not covered by your SpringHouse warranty Installation by a licensed plumber is recommended SpringHouse can be installed outdoors but must be protected from freezing excessive heat and direct sunlight Failure to do so can result in component failure water leakage and or property damage and will void the warranty Install on cold water lines only Install after t...

Page 7: ... Insert provided grounding wire into Grounding Lug connection point and tighten clamp screw 3 3 Attach opposite end of grounding wire to a proper household ground Provided Grounding Clamp to be used metallic plumbing entering facility CAUTION failure to properly ground the unit could lead to serious injury or death ...

Page 8: ...ack canister cap on the unit and filter is numbered Take filter canister 1 remove the filter from the canister and set aside CAUTION Do not over tighten canisters when installing 5 5 Being careful to match the number on the blue canister with the number on the black canister head carefully screw the blue canister into the black portion of the filter canister Hand tighten the canister Snug with sup...

Page 9: ... See figure 5 9 9 Plug the ballast into the top of the UV lamp See figure 6 10 10 Place the plastic cover over the retainer to protect the top to the UV lamp The lamp should be seated low enough in the sleeve so that when the plastic cover is in place there is clearance between it and the cabinet top See figure 7 Plug ballast into properly grounded 110 120 Volt household receptacle 3 3 The quartz ...

Page 10: ...on REASSEMBLY 2 3 Lower cover into place Tighten thumb screws 11 Replace side panels with hook loop tape OPERATION AND MAINTENANCE NOTICE UNPLUG SYSTEM BEFORE PERFORMING ANY OF THE MAINTENANCE PROCEDURES LISTED To open the inlet outlet or bypass valve Turn handle in a counter clockwise direction To close turn in a clockwise direction NOTE Handle will only rotate 1 4 turn Bypass valve should be clo...

Page 11: ...is secured in bucket or drain 14 Open outlet valve see illustration page 5 15 Close bypass valve see illustration page 5 16 Observe tubing to determine that all air has escaped the unit 17 Close pressure relief valve and coil tubing on top of unit 18 Check for leaks before leaving installation 18 Replace unit housing and cover 19 Some cartridges may contain a small amount of fines very fine black ...

Page 12: ...ressurize unit If full flow is not restored repeat the procedure with canisters 1 2 3 5 and 7 6 If full flow is still not restored it is likely that a filter is clogged or faulty Refer to page 11 regarding the changing of filters Gradual Reduction In FlowVolume or Pressure Possible Causes 1 Water pressure to the house from the source has been reduced 2 One or more filter cartridges in the SpringHo...

Page 13: ...13 INSTALLATION NOTES ...

Page 14: ...14 INSTALLATION NOTES ...

Page 15: ...on or usage of the filters and lamps Warranty Limitation Installation of this unit on other than a potable water system will immediately and completely void the warranty The warranty is also voided and provides no coverage where the damage results from improper installation alterations abuse or misuse as determined by EcoQuest International ALL WARRANTIES IMPLIED BY STATE LAW INCLUDING THE IMPLIED...

Page 16: ... antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the Independent Business Owner or an experienced radio TV technician for help FCC DECLARATION OF CONFORMITY EcoQuest Healthy Living Technologies SpringHouse are Trademarked by EcoQuest International EcoQuest Internation...

Reviews: