EcoQuest FreshAir Owner'S Manual Download Page 2

2

3

  1.  Remove protective packaging.

  2.  Remove unit from shipping carton.

  3.  Remove all protective materials.

  4.   Check for shipping damage and loose or broken parts.

  5.   Read Owners Manual thoroughly prior to installation.

  6.  Install batteries in remote. 
  7.   Determine placement location for the unit (See “Placement of 

Unit” on page 9), plug the unit into a 110 volt outlet.

  8.  Be sure the main power switch (on back of unit - see page 5) 

is in the ON position.

  9.  Using either the remote control or the 

Power

 button, turn the 

unit ON. The display should look similar to below.

INSPECTION & INSTALLATION

OPERATION

 1.    Adjust the fan speed to your preference keeping in mind that 

higher fan speeds will give better results. 

  2.  Set the purifier controls anywhere from zero up to the total area 

of the indoor environment. 

   

Do not set the area indicated by the purifier above the square footage 
(or square meters for international models) of the indoor area.

  3.   To operate the sanitize feature, press the sanitize button 

until the desired time is reached (2, 4, 6, or 8 hours). The unit 
will display SANITIZE and the remaining time in hours and 
minutes (see below). Make sure the area is unoccupied before 
using the sanitizer. To interupt the sanitize feature before the 
timer reaches zero, press the 

Purifier On/Off

 button.

Sanitize Mode

Fan Speed (Max)

SANITIZE MODE: The unit’s display will change when the Sanitize function is 
active. The fan will show maximum and SANITIZE will replace the purifier setting. 
The amount of time remaining will depend on how long you have selected for the 
Sanitize function to operate. The colon (:) will flash to indicate time being counted 
down.

Time Remaining

Purifier Setting

Fan Speed

Purifier Coverage

NORMAL MODE: The unit’s display shows the fan speed (low to high), the 
purifier setting (1 bar to 12 bars), and the purifier coverage in square feet for 
U.S. models and square meters for international units.

Inspection & Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Your New Fresh Air by EcoQuest:. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Unit Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Settings and Adjustments  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Maintenance and Service Reminders  . . . . . . . . . . . . . . . . . . . . . . . . 7
LCD Display  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
General Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Placement of Unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Optional EcoHelp Filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Removing the Lint Screen  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Removing the Purifier Plate & RCI

 Target  . . . . . . . . . . . . . . . . . . . 11

Removing the UV Bulb and Starter  . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installing the UV Lamp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Installing RCI

 Target & Purifier Plate  . . . . . . . . . . . . . . . . . . . . . . . 12

Installing the Lint Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Warranty Information   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

INTRODUCTION

Congratulations, you have purchased one of the most effective, 
technologically advanced air purifiers available. Your new 
Fresh Air by EcoQuest is designed to provide years of trouble-
free, low maintenance operation. Be sure to read and follow all 
service procedures outlined in this owner’s manual and to use 
only genuine EcoQuest replacement parts available from your 
EcoQuest Dealer.

If you have any questions concerning this or any EcoQuest 
product, contact your EcoQuest Dealer.
Please record the name and phone of your EcoQuest Dealer: 

Name _______________________________________________

Phone _______________________________________________

Please record the serial number of your Fresh Air by EcoQuest:

Serial # ______________________________________________

CONTENTS

To reduce the risk of electric shock, this equipment has a 
grounding type plug that has a third (grounding) pin. This 
plug will only fit into a grounding type power outlet. If the 
plug does not fit into the outlet, contact qualified personnel 
to install the proper outlet. Do not alter the plug in any way

.

This owner’s manual is also available online at:
http://www.ecoquest.com/ownersmanuals

Summary of Contents for FreshAir

Page 1: ...OWNERS MANUAL Installation Operation Specifications Features Maintenance Warranty 65 00087 008 REV 0905 FAOM15_0905 ...

Page 2: ...r Coverage NORMAL MODE The unit s display shows the fan speed low to high the purifier setting 1 bar to 12 bars and the purifier coverage in square feet for U S models and square meters for international units Inspection Installation 3 Operation 3 Specifications 4 Your New Fresh Air by EcoQuest 4 Unit Features 5 Settings and Adjustments 6 Maintenance and Service Reminders 7 LCD Display 7 General M...

Page 3: ...variables such as severity and frequency of pollution humidity and temperature Warranty Length of warranty will vary depending on model See warranty card for specific details YOUR NEW FRESH AIR BY ECOQUEST Eliminates smoke odors and tobacco smoke Sanitize feature kills mold mildew and bacteria in unoccupied spaces UVC light helps kill airborne germs as they pass through the unit Removes odors from...

Page 4: ...essage All the other service reminders will clear automatically once the unit has been turned off and back on and the problem has been corrected SEE PAGES 10 13 FOR REMOVAL AND INSTALLATION INSTRUCTIONS Be sure to press the Reminder Reset button to clear the reminder following regular maintenance SETTINGS AND ADJUSTMENTS Fresh Air by EcoQuest can be turned on or off and adjusted using either the i...

Page 5: ...to keep your unit running at top performance CAUTION Unplug the unit before performing any maintenance procedures Cleaning the Case Wipe the unit with a soft cloth dampened with water Do not use chemicals or solvents Vacuum the front and rear grills periodically to remove any lint buildup Cleaning the RCI Target Remove the RCI Target and rinse with warm water Allow to dry completely before reinsta...

Page 6: ...ove the purification plate grasp edge of plate in the center and gently pull out NOTE If the plate is difficult to remove gently press down on the lower metal contact tab 5 4 3 1 2 REMOVING THE LINT SCREEN 1 Unplug unit 2 Remove the two 2 back cover screws 3 Remove back cover 4 Remove two 2 screws securing the top of the lint screen holder WARNING DO NOT OPERATE Fresh Air by EcoQuest without the l...

Page 7: ...ns see pages 10 11 6 4 3 2 1 INSTALLING THE UV LAMP 1 Insert UV bulb into holder then rotate to lock into place 2 Replace starter and turn to lock 3 Replace cage by lowering and sliding back into place Tighten two 2 screws securely 5 5 Replace the RCI Target by gently inserting into the large guides until the screen stops 6 Gently insert the purifier plate between the guides inside the cage until ...

Page 8: ...he answers for question 2 as it would apply to this question also 4 The UV lamp is not functioning I m getting a Replace Lamp message Check lamp for proper installation Replace UV Lamp PLEASE NOTE If unit has been recently transported check lamp for proper installation remove Lamp and reinstall 5 What are the most typical application problems Symptom A belief that the proper equipment is placed in...

Page 9: ... questions concerning your Fresh Air by EcoQuest please see your local EcoQuest Dealer For help visit www EcoQuest com This equipment has been tested and found to comply with the limits for Industrial Scientific and Medical Equipment ISM pursuant to Part 18 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This eq...

Reviews: