Cleaning
Troubleshooting
7
Depending on conditions, your Fresh Air To Go will require periodic
cleaning of certain internal components every one to three months.
To perform proper cleaning, remove the RCI Target, UV bulb, and
Ecotech Purification Plate as shown (see
Dissasembly
, page 6).
RCI Target
Clean the target with a soft brush and hot water. Allow to dry
thoroughly before reinstalling.
UV Bulb
The UV bulb should be gently wiped with a soft, dry cloth. Avoid
handling the UV bulb more than necessary.
Ecotech Purification Plate
The top area of the Ecotech Purification Plate can be cleaned with
ammonia or alcohol and a cotton swab. Do not use water.
Case
Clean the exterior case of your Fresh Air To Go with a soft cloth
dampened (not wet) with water. Do not use harsh chemicals or
solvents.
Fan / Interior of unit
The interior and fan may be cleared of dust using canned air
suitable for electronics.
WARNING: Under no circumstances should your Fresh Air To Go unit be operated
while any part of the case is damaged, missing, or disassembled. If the case is
damaged, return your unit to EcoQuest for repair or replacement. Direct exposure to
the internal UV light may cause eye damage.
Unit does not operate / the fan does not operate / all LEDs off
• Unplug and reinsert the adapter plug and adapter.
• Press the FAN UP or FAN DOWN buttons to turn the unit on.
• If using the 12VDC car adapter, remove the fuse by unscrewing the end of the adapter
and check to see if it is blown. Replace it with the same type and rating fuse only (see
Specifications
). If the fuse is not blown, check the outlet for proper voltage.
Purifier Plate / UV bulb may not be working
• Press the PURIFIER UP or PURIFIER DOWN buttons to turn the Purifier function ON.
• Remove the UV bulb and Ecotech Purification Plate, clean, and reinstall (see
Disassembly
and
Cleaning
).
• If cleaning and reinstalling the plate does not correct the problem, replace the plate.
• When looking through the rear inlet vents in low light you should see a slight bluish
glow. If there is no glow and reinstalling doesn’t correct the problem, replace the bulb.
Lack of air flow
• Make sure the intake vents are not blocked and the front of the unit is clear.
• Check to see if the fan is operating (if not, see above).
If your unit fails to operate properly after performing troubleshooting, contact your
EcoQuest Dealer for further assistance, contact EcoQuest at the address in this manual,
or visit www.EcoQuest.com for additional support.