Disassembly
6
1. Turn unit over and remove screw
at the front of the unit.
2. Tilt the front of the lower half of
the case up about 1/2 inch.
3. With the front tilted up, slide the lower
half of the case back until it is free.
4. Press the ends of the RCI target to
release it as you pull up.
5. Remove the RCI Target from
the unit.
6 Remove the UV bulb by gently
pulling straight up.
7. Remove the Ecotech Purification
Plate by gently pulling straight up.
All user maintainable parts
of the Fresh Air To Go are
accessed by removing the
lower half of the case. The
unit must be disconnected
from its power source before
servicing, and should not
have the power reconnected
unless the case is correctly
and completely reassembled.
Yearly Maintenance
A service kit is available
for your Fresh Air To Go.
The kit contains a new
RCI Target, UV bulb, and
EcoTech Purification Plate.
For optimum performance,
EcoQuest recommends
replacing these components
annually. See your EcoQuest
Dealer for more Information.
8. Reinstallation is the reverse of the above steps:
• EcoTech Purification Plate - align the four pins with the four sockets and press gently.
• UV lamp - align the two bulb wires with the two sockets at the ends of the plate and insert.
• RCI Target - install the “legs” of the target into the four holes in the green PC board.
• Carefully replace the bottom case being sure the pins inside the back of the bottom case fit
into the two standoffs at back of the top case. Slide the bottom case forward then down.
• Check for proper case alignment before installing and tightening the screw. Failure to
correctly assemble may cause damage to the case.