chamber such that the flexible connector can reach the inlet port at the bottom of the 

chamber.  Also ensure that there is at least 27” of clearance above the UV sterilizer to allow 

for lamp and sleeve removal.  Depending on the location of your outgoing water line, you 

can mount the outlet of the UV sterilizer so that its outlet port is on the right or left. 

 

Step 14. – Turn Off Water & Electric Water Heaters 

 

 

FAILURE TO FOLLOW THIS PROCEDURE COULD RESULT IN SERIOUS, PERMANENT 

DAMAGE TO THE HEATING ELEMENTS IN YOUR WATER HEATER.   

 

If you have a conventional electric water heater or an on-demand (tankless) electric water 

heater, we highly recommend that you turn off the power to the heater while installing any 

water treatment equipment.  Turn off power to your water heater now. 

 

Turn off the household main water shutoff valve.  Open several plumbing fixtures inside the 

home as well as the outside faucets to drain as much water out of the plumbing system as 

possible. 

 

Following completion of the entire installation, restore the water flow by turning on the 

household main water valve and allow all air to be purged from the plumbing system before 

turning the power back on to your water heater.   

 

Step 15. – Connect System to Inlet and Outlet Pipes 

 

The 1 inch NPT stainless steel fitting on the inlet side of the cartridge filter housing cap 

should be plumbed to your incoming water supply pipe.   

 

If within reach, this can be done with one of the flexible stainless steel connectors provided 

with your system if you have 1 inch PEX, copper, or CPVC water lines.  The non-threaded end 

of the connector can be connected directly to 1 inch diameter PEX, copper, or CPVC tubing 

by pushing the fitting on to the tubing as far as it will go.  Unlike the other John Guest® 

fittings used previously in the installation, there is no locking collet.  The black end of the 

flexible stainless steel connector threads onto the stainless steel fitting in the same way as 

you would attach a garden hose to an outdoor faucet.  Do not use Teflon® tape of other 

Summary of Contents for EP-1000-ULT

Page 1: ...TION GUIDE ecoPLUS EP 1000 ULT PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION FAILURE TO FOLLOW THESE INSTRUCTIONS MAY AFFECT THE PERFORMANCE OF YOUR SYSTEM VOID YOUR WARRANTY AND RE...

Page 2: ...amaging effects of these contaminants Our ecoTAC hard water conditioners use a salt free water treatment technology called Template Assisted Crystalization or TAC for short to prevent hard water scale...

Page 3: ...p 8 Connect the Inlet Assembly to the Housing Cap 15 Step 9 Connect the Bypass to the Inlet Assembly 16 Step 10 Connect the ecoPLUS Tank to the Inlet Assembly 16 Step 11 Connect Bridge Assembly to the...

Page 4: ...avy components without assistance if you are not physically capable of safely carrying out the procedure If the water treatment system is to be left unattended for an extended period of time vacation...

Page 5: ...SYSTEM DAMAGE INCLUDING WATER LEAKS AND CORRESPONDING PROPERTY DAMAGE AND MAY VOID YOUR WARRANTY It is very important to note that the presence of elevated levels of chlorine iron manganese hydrogen...

Page 6: ...hstand pressures exceeding 90 PSI if your water pressure is greater than 70 PSI we recommend that you have a certified plumber install a pressure reducing valve ahead of the ecoPLUS system The system...

Page 7: ...INIMIZE ANY PROBLEMS WITH COPPER AVOID APPLYING EXCESS FLUX ON THE INNER SURFACES OF THE PIPE AND USE A LOW CORROSIVITY WATER SOLUBLE FLUX LISTED UNDER THE ASTM B813 STANDARD FOR HOMES WITH SIGNIFICAN...

Page 8: ...8 Step 1 Pre Installation Inspection...

Page 9: ...el Connectors 1 Quick Connect to 1 NPT 8 Outlet Assembly 9 Inlet Assembly 10 Spanner Wrench 11 Small Parts Bag 8 Lag Bolts and 8 Washers 12 ecoTAC Media Tank and Valve Head 13 Bridge Assembly 14 UV Co...

Page 10: ...n space required for this model is 42 Wide x 66 High x 21 5 Deep In most cases the system should be installed after the branch line s to exterior irrigation unless you want your exterior faucets to de...

Page 11: ...tach the cartridge filter housing cap and mounting bracket to your wall using the remaining four 4 lag bolts and washers as shown below The top of the mounting bracket should be mounted EXACTLY 52 3 4...

Page 12: ...nsuring that it is securely screwed into the wall studs When the cartridge filter housing is full of water it is heavy so it is important to ensure that the mounting will be strong enough to support t...

Page 13: ...sump containing the filter cartridge onto the cartridge filter housing cap Hand tighten only do not use the spanner wrench Do not over tighten Excessive force is not required to obtain a good seal Ste...

Page 14: ...he treatment tank This is completely normal and is necessary to allow the required freeboard to permit the media bed to completely fluidize during operation When water begins to flow into the bottom o...

Page 15: ...Cap Refer to John Guest Quick Connect Style Fittings above First ensure the John Guest fitting is unlocked Then push the elbow end of the inlet assembly on to the black stem adapter as far as it will...

Page 16: ...hed to the rest of the tank If your tank appears to be crooked the base has likely been knocked out of alignment during shipping This can be correct by picking the tank up and tapping it on a hard sur...

Page 17: ...17 go to next page...

Page 18: ...S treatment tank The black base of the media tank is not permanently attached to the rest of the tank If your tank appears to be crooked the base has likely been knocked out of alignment during shippi...

Page 19: ...s not required to obtain a good seal The other end to the inlet bottom port on the UV disinfection chamber in the same manner The flexible connector can be bent to reach the UV chamber which should be...

Page 20: ...s much water out of the plumbing system as possible Following completion of the entire installation restore the water flow by turning on the household main water valve and allow all air to be purged f...

Page 21: ...r incoming water line It is designed to be bent a many times but not repeatedly over and over Doing so may reduce the structural integrity of the fitting Alternatively you can make the plumbing connec...

Page 22: ...sulted from the installation Once the water is running clear and free of air close the water tap INSPECT ALL PLUMBING CONNECTIONS AND THE INTERFACE BETWEEN THE MEDIA TANK AND ITS VALVE HEAD FOR LEAKS...

Page 23: ...t is normal for the water to be discolored at this stage as carbon fines are purged from the system Gradually increase the flow rate a little more and run the water until it is completely clear If you...

Page 24: ...bottom drain valve on the hot water heater 30 to 60 days after installation of ecoTAC Be sure to turn off the electricity to your water heater before draining your tank Follow the manufacturer s inst...

Page 25: ...sily wiped down because they can no longer adhere to the sides of the shower TROUBLESHOOTING Problem Solution Reduced water pressure and or flow rate after initial installation Limit high flow rate de...

Page 26: ...T SEVERAL FAUCETS Cleaning The outside of your system including cartridge filter housing and media tank can be washed with a mild soap and water if desired Do NOT use strong cleaners as they may cause...

Page 27: ...ot be stopped Put the O ring in a safe place where it will not get dirty or otherwise contaminated Replacement O Ring Pentek Buna N Big Blue O Ring 151122 4 Take out the used filter cartridge and disc...

Page 28: ...or our ecoTAC hard water conditioner this may need to be done every few months If you have soft water or you have treatment for your hard water problem sleeve cleaning is generally only required once...

Page 29: ...lytic Activated Carbons Calgon Carbon Corporation Moon Township PA USA Made in USA NSF ANSI Standard 61 KDF 55 Process Media KDF Fluid Treatment Inc Three Rivers MI USA Made in USA NSF ANSI Standard 4...

Page 30: ...mprehensive warranty program including Limited Lifetime Warranty on major components Major components including the cartridge filter housing media tank s riser tube s upper media screen s and tank val...

Page 31: ...This warranty applies only in Canada and the United States of America In the event that a part is deemed defective the user must immediately inform HomePlus Products Inc who will furnish a replacemen...

Page 32: ...xceed the actual purchase price paid by the authorized distributor or consumer for the product In no event shall HomePlus Products Inc be liable to the distributor or any other person or entity for sp...

Reviews: